Liqiang Wang
Research Subjects
Liqiang Wang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Hang Wang
Hubei Engineering Research Center for Safety Monitoring of New Energy and Power Grid Equipment, Hubei University of Technology, Wuhan 430068, China
2 shared publications - Jing Tu
Electrical Cable Operation and Maintenance Branch of Wuhan Power Supply Company, Hubei Power Supply Company, State Grid, Wuhan 430024, China
2 shared publications - Jun Chen
School of Electrical & Electronic Engineering, Hubei University of Technology, Wuhan 430068, China
2 shared publications - Bo Li
Hubei Engineering Research Center for Safety Monitoring of New Energy and Power Grid Equipment, Hubei University of Technology, Wuhan 430068, China
1 shared publication - Shuai Yang
Hubei Engineering Research Center for Safety Monitoring of New Energy and Power Grid Equipment, Hubei University of Technology, Wuhan 430068, China
1 shared publication - Wenfang Ding
Hubei Engineering Research Center for Safety Monitoring of New Energy and Power Grid Equipment, Hubei University of Technology, Wuhan 430068, China
1 shared publication
Latest Publications
- Open Access
Sheath-to-Ground Fault Impedance Calculation and Localization Method in Cross-Bonded High-Voltage Cable Systems
Abnormal circulating current induced by sheath grounding faults in cross-bonded high-voltage cables is a major cause of single-phase grounding faults. For the early detection and localization of sheath grounding faults, this paper constructs an equivalent circuit model for three-phase nine-section cross-bonded cables. Circuit model parameters are estimated via online monitoring data. The relational equation between sheath electrical quantities, fault impedance, and distance is derived for typical sheath grounding faults. Using the Adam algorithm, the solution of fault impedance and location is converted into the minimization of an optimization objective function. Simulation results show that under the influences of phase current imbalance, measurement error, and fault impedance fluctuation, the Adam algorithm exhibits superior optimization accuracy and computational efficiency in comparison with the ED and GA algorithms. Experimental results show that for low-resistance sheath grounding, the proposed method has a fault impedance calculation error ≤ 0.59% and a fault positioning error ≤ 1.89%. For metallic sheath grounding with zero resistance, the positioning error is ≤1.37%. Field test results demonstrate that the proposed method performs similarly to the time-domain reflectometry method, with a positioning deviation ≤ 0.15 m, and can meet online monitoring requirements.
Open AccessSheath-to-Ground Fault Impedance Calculation and Localization Method in Cross-Bonded High-Voltage Cable Systems
Abnormal circulating current induced by sheath grounding faults in cross-bonded high-voltage cables is a major cause of single-phase grounding faults. For the early detection and localization of sheath grounding faults, this paper constructs an equivalent circuit model for three-phase nine-section cross-bonded cables. Circuit model parameters are estimated via online monitoring data. The relational equation between sheath electrical quantities, fault impedance, and distance is derived for typical sheath grounding faults. Using the Adam algorithm, the solution of fault impedance and location is converted into the minimization of an optimization objective function. Simulation results show that under the influences of phase current imbalance, measurement error, and fault impedance fluctuation, the Adam algorithm exhibits superior optimization accuracy and computational efficiency in comparison with the ED and GA algorithms. Experimental results show that for low-resistance sheath grounding, the proposed method has a fault impedance calculation error ≤ 0.59% and a fault positioning error ≤ 1.89%. For metallic sheath grounding with zero resistance, the positioning error is ≤1.37%. Field test results demonstrate that the proposed method performs similarly to the time-domain reflectometry method, with a positioning deviation ≤ 0.15 m, and can meet online monitoring requirements.
- Open Access
Cross-Bonded Cable Circuits Identification Based on Deep Embedded Clustering of Sheath Current Sensing
Online identification of HV cable circuits is vital for routine inspection and maintenance, yet existing passive electromagnetic wave injection methods are limited to offline operations. To fill the gap and achieve the online identification of HV cable circuits, an online circuit identification methodology based on sheath current temporal characteristics and deep embedded clustering is proposed. First, an equivalent circuit model of the multi-circuit cross-bonded cable sheath was built to deduce the temporal similarity of sheath currents within the same circuit, establishing the identification criterion. Second, the robustness of the temporal similarity under various operating conditions was verified via simulation based on the Dynamic Time Warping (DTW) distance. Then, a combined model of Temporal Convolutional Network Autoencoder (TCN-AE) and K-medoids was established to transform circuit identification into a temporal clustering problem of sheath currents, realizing circuit determination by synchronously monitoring the time-series sheath current data of multi-circuit HV cross-bonded cables. The method was verified on a full-scale 110 kV cable test platform. The results show that the identification accuracy reached 95.37%, and the proposed method can effectively identify the circuits of cross-bonded cables with high robustness against the domain gap, having significant engineering application value.
Open AccessCross-Bonded Cable Circuits Identification Based on Deep Embedded Clustering of Sheath Current Sensing
Online identification of HV cable circuits is vital for routine inspection and maintenance, yet existing passive electromagnetic wave injection methods are limited to offline operations. To fill the gap and achieve the online identification of HV cable circuits, an online circuit identification methodology based on sheath current temporal characteristics and deep embedded clustering is proposed. First, an equivalent circuit model of the multi-circuit cross-bonded cable sheath was built to deduce the temporal similarity of sheath currents within the same circuit, establishing the identification criterion. Second, the robustness of the temporal similarity under various operating conditions was verified via simulation based on the Dynamic Time Warping (DTW) distance. Then, a combined model of Temporal Convolutional Network Autoencoder (TCN-AE) and K-medoids was established to transform circuit identification into a temporal clustering problem of sheath currents, realizing circuit determination by synchronously monitoring the time-series sheath current data of multi-circuit HV cross-bonded cables. The method was verified on a full-scale 110 kV cable test platform. The results show that the identification accuracy reached 95.37%, and the proposed method can effectively identify the circuits of cross-bonded cables with high robustness against the domain gap, having significant engineering application value.