JKJiwoong Kim

Jiwoong Kim

*This is an algorithmically generated author record based on publicly available information.

Jiwoong Kim has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Integrated multiscale modeling and coordinated balance-of-plant optimization to maximize vehicle system efficiency in a heavy-duty fuel cell electric vehicle

    by Jiwoong Kim, Sehyeon Kim, Hosik Lee, Sanggyu Kang, Kyoungdoug Min

    This study presents an integrated multiscale modeling and optimization framework for polymer electrolyte membrane fuel cell (PEMFC) systems in a heavy-duty fuel cell electric vehicle (FCEV). The influence of balance-of-plant (BoP) operation on parasitic power consumption and vehicle system efficiency was quantitatively investigated. The integrated model combined the air supply system, thermal management system (TMS), and a quasi-three-dimensional stack model to capture the coupled electrochemical and thermal behavior under realistic operating conditions. The air supply system was validated using component-level experimental data, while the TMS was validated via full-scale chassis dynamometer tests. The model accurately reproduced transient responses, including temperature and pressure, with coefficients of determination (R2) exceeding 0.95. Vehicle-level analysis identified the radiator hydraulic fan pump as the dominant contributor to parasitic losses across the entire operating range. To maximize stack voltage and vehicle system efficiency, the coordinated BoP control parameters were optimized using a Box-Behnken design, Pareto analysis, and response surface methodology under a thermal constraint on the stack coolant outlet temperature. At the maximum stack load of 95 kW, the fan pump consumed 17.18 kW, while the air compressor and coolant pump consumed 12.45 kW and 0.80 kW per stack, respectively. Under the coordinated BoP strategy, the stack voltage and vehicle system efficiency improved by 1.88 and 4.03 %, respectively, demonstrating that coordinated BoP control effectively reduces parasitic losses under high-load conditions. The proposed framework provides a validated foundation for system-level BoP optimization and supports the development of high-efficiency control strategies in commercial heavy-duty FCEVs.

  • Open Access

    Hydration-dependent electrochemical parameters for improved performance modeling of polymer electrolyte membrane fuel cells

    by Sehyeon Kim, Jiwoong Kim, Hyunsoo Chun, Junghyo Chang, Jihun Shin, Sanggyu Kang, Kyoungdoug Min

    Membrane hydration affects not only proton conductivity but also the accessibility of catalytic sites and hydrogen permeation in polymer electrolyte membrane fuel cells (PEMFCs). However, most performance models treat the electrochemical surface area (ECSA) and hydrogen crossover current density as constant parameters, potentially leading to misinterpretation of activation overpotentials under low-humidity operation. In this study, the hydration- and temperature-dependent behaviors of ECSA and hydrogen crossover were quantified for an expanded polytetrafluoroethylene-reinforced membrane electrode assembly. Water vapor sorption was measured by dynamic vapor sorption and analyzed with a new dual-mode sorption model to determine equilibrium hydration states and identify a clustering-related regime transition. In-situ cyclic voltammetry and linear sweep voltammetry were conducted over a wide range of relative humidity and temperature, yielding empirical correlations for ECSA and hydrogen crossover current density with adjusted coefficients of determination (Radj2) exceeding 0.990. Both parameters exhibited a two-regime dependence on hydration, consistent with a clustering-based transition in the membrane water structure. Incorporation of the hydration- and temperature-dependent correlations into a quasi-three-dimensional PEMFC model significantly improved the prediction of activation overpotentials in the low current density regime, reducing the maximum root mean squared error from 14.1 to 7.3 mV under dry conditions. These results support the need to include hydration- and temperature-dependent electrochemical parameters for reliable PEMFC performance prediction under low-humidity operation.

  • Open Access

    Integrated multiscale modeling and coordinated balance-of-plant optimization to maximize vehicle system efficiency in a heavy-duty fuel cell electric vehicle

    by Jiwoong Kim, Sehyeon Kim, Hosik Lee, Sanggyu Kang, Kyoungdoug Min

    This study presents an integrated multiscale modeling and optimization framework for polymer electrolyte membrane fuel cell (PEMFC) systems in a heavy-duty fuel cell electric vehicle (FCEV). The influence of balance-of-plant (BoP) operation on parasitic power consumption and vehicle system efficiency was quantitatively investigated. The integrated model combined the air supply system, thermal management system (TMS), and a quasi-three-dimensional stack model to capture the coupled electrochemical and thermal behavior under realistic operating conditions. The air supply system was validated using component-level experimental data, while the TMS was validated via full-scale chassis dynamometer tests. The model accurately reproduced transient responses, including temperature and pressure, with coefficients of determination (R2) exceeding 0.95. Vehicle-level analysis identified the radiator hydraulic fan pump as the dominant contributor to parasitic losses across the entire operating range. To maximize stack voltage and vehicle system efficiency, the coordinated BoP control parameters were optimized using a Box-Behnken design, Pareto analysis, and response surface methodology under a thermal constraint on the stack coolant outlet temperature. At the maximum stack load of 95 kW, the fan pump consumed 17.18 kW, while the air compressor and coolant pump consumed 12.45 kW and 0.80 kW per stack, respectively. Under the coordinated BoP strategy, the stack voltage and vehicle system efficiency improved by 1.88 and 4.03 %, respectively, demonstrating that coordinated BoP control effectively reduces parasitic losses under high-load conditions. The proposed framework provides a validated foundation for system-level BoP optimization and supports the development of high-efficiency control strategies in commercial heavy-duty FCEVs.

  • Open Access

    A novel approach to modeling of polymer electrolyte membrane fuel cells with vehicle-level validation in a hydrogen electric vehicle

    by Jiwoong Kim, Sehyeon Kim, Seong-Yong Woo, Jaebong Sim, Hosik Lee, Sanggyu Kang, Kyoungdoug Min

    This study presents a novel modeling approach for polymer electrolyte membrane fuel cells (PEMFCs), validated at both the single-cell and stack levels in a hydrogen electric vehicle. An extensive single-cell experiment was conducted to investigate the impacts of operating conditions (i.e., temperature, relative humidity, and pressure), leading to the development of a detailed PEMFC model incorporating newly derived water transport properties of a reinforced composite membrane (RCM). Unlike conventional models (CM) based on Nafion correlations, the RCM model successfully reproduced the distinct transport characteristics of the reinforced membrane. As a result, predictive accuracy was markedly enhanced, with the maximum root mean square error (RMSE) reduced from 41.0 mV (CM) to 6.3 mV (RCM). The model achieved an adjusted coefficient of determination (Radj2) of 0.988 and a maximum relative error below 2.01 %. Additionally, the model enabled analysis of through-plane distributions of temperature and water concentration (vapor and liquid), highlighting the saturation factor in the serpentine flow field configuration. At the stack level, chassis dynamometer tests under dynamic loads validated the model, with correction factors applied to account for flow channel differences. With these refinements, the stack model achieved an Radj2 of 0.994 and a maximum relative error below 3.15 %. This study bridges the gap between single-cell and stack-scale operation by integrating electrochemical and water transport effects into a scalable framework, providing a robust tool for predicting PEMFC performance under dynamic conditions.