Junhao Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Junhao Zhang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Muyinatu A. Lediju Bell
Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, USA
2 shared publications - Amanda Rae Maxwell
Johns Hopkins University, Department of Molecular and Comparative Pathobiology, Baltimore, Maryland, United States
1 shared publication Cynthia Li
Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, 21218, MD, USA
1 shared publication- Jiaxin Zhang
Johns Hopkins University, Department of Electrical and Computer Engineering, Baltimore, Maryland, United States
1 shared publication - Junior Arroyo
Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
1 shared publication - Kathleen L. Gabrielson
Department of Oncology, The Johns Hopkins University School of Medicine
1 shared publication
Latest Publications
- Open Access
- 1 May 2026
- Published by Elsevier in Photoacoustics
- Vol. 50, 100827
Real-time photoacoustic imaging with freehand light delivery and augmented reality guidance
- 1 May 2026
- Published by Elsevier in Photoacoustics
- Vol. 50, 100827
Open AccessReal-time photoacoustic imaging with freehand light delivery and augmented reality guidance
- Open Access
- 1 March 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (03) , 1-12
In vivo photoacoustic imaging of swine ureters injected with methylene blue
SignificanceUreteral injuries represent a major concern during a range of surgical procedures, due to the proximity of the ureter to target surgical structures. Intraoperative identification of the ureter is critical to prevent this accidental damage.AimWe demonstrate the first known in vivo photoacoustic imaging of the ureter in swine following intravenous administration of FDA-approved methylene blue, enabled by a software-hardware integration that has not been previously reported in the literature.ApproachPhotoacoustic channel data from the ureters of two swine were acquired using a Vevo F2 ultrasound system and an Opotek Phocus Mobile laser. Images were beamformed using a delay-and-sum algorithm. Photoacoustic image quality was evaluated using contrast, signal-to-noise ratio (SNR), and generalized contrast-to-noise ratio (gCNR) metrics, measured 10 to 80 min after methylene blue injection.ResultsAcross the 10- to 80-min imaging window, median contrast (3.46–11.43 dB), SNR (2.84–6.99), and gCNR (0.27–0.64) confirmed sustained ureter visibility with methylene blue. Maximum image quality was observed 20- to 30-min after methylene blue injection, with significantly higher contrast, SNR, and gCNR values compared with earlier or later time points (p<0.05).ConclusionsIn vivo results demonstrate that methylene-blue-enhanced photoacoustic imaging can visualize the ureter over a time duration that is consistent with the length of surgical procedures, providing initial feasibility for real-time photoacoustic-guided surgery applications.
- 1 March 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (03) , 1-12
Open AccessIn vivo photoacoustic imaging of swine ureters injected with methylene blue
SignificanceUreteral injuries represent a major concern during a range of surgical procedures, due to the proximity of the ureter to target surgical structures. Intraoperative identification of the ureter is critical to prevent this accidental damage.AimWe demonstrate the first known in vivo photoacoustic imaging of the ureter in swine following intravenous administration of FDA-approved methylene blue, enabled by a software-hardware integration that has not been previously reported in the literature.ApproachPhotoacoustic channel data from the ureters of two swine were acquired using a Vevo F2 ultrasound system and an Opotek Phocus Mobile laser. Images were beamformed using a delay-and-sum algorithm. Photoacoustic image quality was evaluated using contrast, signal-to-noise ratio (SNR), and generalized contrast-to-noise ratio (gCNR) metrics, measured 10 to 80 min after methylene blue injection.ResultsAcross the 10- to 80-min imaging window, median contrast (3.46–11.43 dB), SNR (2.84–6.99), and gCNR (0.27–0.64) confirmed sustained ureter visibility with methylene blue. Maximum image quality was observed 20- to 30-min after methylene blue injection, with significantly higher contrast, SNR, and gCNR values compared with earlier or later time points (p<0.05).ConclusionsIn vivo results demonstrate that methylene-blue-enhanced photoacoustic imaging can visualize the ureter over a time duration that is consistent with the length of surgical procedures, providing initial feasibility for real-time photoacoustic-guided surgery applications.