Runsheng Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Runsheng Zheng has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Lei Shang
Wuhan University
4 shared publications - Song Zhang
Electric Power Research Institute of Guizhou Power Grid Co., Ltd., Guiyang 550002, China
3 shared publications - Chang Xu
Guizhou Power Grid Co., Ltd., Guiyang 550001, China
2 shared publications - Wenjun Han
Guizhou Power Grid Co., Ltd., Guiyang 550001, China
2 shared publications - Yongxiang Cai
Electric Power Research Institute of Guizhou Power Grid Co., Ltd., Guiyang 550002, China
2 shared publications - Zefang Dong
School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
2 shared publications
Latest Publications
- Open Access
- 1 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (15) , 3406
Constraint-Aware Predictive Energy Coordination of Multiple Energy-Storage Converters for DC Bus Stabilization
Direct current (DC) bus voltage stability in grid-connected microgrids with multiple energy-storage converter branches is governed by the coupled dynamics of photovoltaic generation, heterogeneous battery storage, and the grid-connected inverter. Conventional independent and droop control methods allocate branch power mainly from local voltage or state-of-charge information, and therefore cannot fully account for converter limits, battery condition, or inverter current admissibility. This paper proposes a constraint-aware predictive energy coordination (CAPEC) method for DC bus stabilization. A DC bus energy model with variable losses is combined with one-step disturbance prediction and a safety governor that allocates storage power according to state of charge (SOC), state of health (SOH), power reserve, thermal margin, current capability, and ramp limits. The grid-connected inverter is treated as a constrained energy regulation path with active power saturation and antiwindup correction. Small-signal and energy function analyses show that CAPEC increases equivalent DC bus damping and yields bounded voltage recovery for feasible references and bounded prediction errors. MATLAB R2023b studies for combined photovoltaic and load variation, grid interface disturbance, and heterogeneous storage conditions show that CAPEC limits the maximum voltage deviation to 2.86 to 6.35 V. A reduced power laboratory experiment further verifies the Case B breaker disturbance and confirms stable DC bus behavior during unplanned grid interface switching.
- 1 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (15) , 3406
Open AccessConstraint-Aware Predictive Energy Coordination of Multiple Energy-Storage Converters for DC Bus Stabilization
Direct current (DC) bus voltage stability in grid-connected microgrids with multiple energy-storage converter branches is governed by the coupled dynamics of photovoltaic generation, heterogeneous battery storage, and the grid-connected inverter. Conventional independent and droop control methods allocate branch power mainly from local voltage or state-of-charge information, and therefore cannot fully account for converter limits, battery condition, or inverter current admissibility. This paper proposes a constraint-aware predictive energy coordination (CAPEC) method for DC bus stabilization. A DC bus energy model with variable losses is combined with one-step disturbance prediction and a safety governor that allocates storage power according to state of charge (SOC), state of health (SOH), power reserve, thermal margin, current capability, and ramp limits. The grid-connected inverter is treated as a constrained energy regulation path with active power saturation and antiwindup correction. Small-signal and energy function analyses show that CAPEC increases equivalent DC bus damping and yields bounded voltage recovery for feasible references and bounded prediction errors. MATLAB R2023b studies for combined photovoltaic and load variation, grid interface disturbance, and heterogeneous storage conditions show that CAPEC limits the maximum voltage deviation to 2.86 to 6.35 V. A reduced power laboratory experiment further verifies the Case B breaker disturbance and confirms stable DC bus behavior during unplanned grid interface switching.
- Open Access
- 15 June 2026
- Published by MDPI AG in Electronics
- Vol. 15 (12) , 2643
Unified DFIG Control Strategy for Stability Support and Coordinated Power Export in Microgrid Clusters
This paper investigates AC microgrid clusters with high penetration of DFIG-based wind power. Conventional separated control of wind power output and stability support may cause abrupt power command variations during transitions between grid-connected and islanded operating modes, thereby aggravating system power imbalance. To address this issue, a unified DFIG control strategy is proposed in which an operating objective coordination factor continuously coordinates stability support and wind power output within a unified reference generation framework. A continuity preservation mechanism is then developed to suppress transient impacts through phase angle coordination and DC link power correction. Simulation results show that, compared with conventional MPPT + PQC and FSC methods, the proposed strategy mitigates transition induced fluctuations during grid island transitions. RTDS experiments based on a modified Banshee microgrid model further verify that the proposed strategy improves system stability during grid-connected to islanded transition and islanded to grid connected reconnection.
- 15 June 2026
- Published by MDPI AG in Electronics
- Vol. 15 (12) , 2643
Open AccessUnified DFIG Control Strategy for Stability Support and Coordinated Power Export in Microgrid Clusters
This paper investigates AC microgrid clusters with high penetration of DFIG-based wind power. Conventional separated control of wind power output and stability support may cause abrupt power command variations during transitions between grid-connected and islanded operating modes, thereby aggravating system power imbalance. To address this issue, a unified DFIG control strategy is proposed in which an operating objective coordination factor continuously coordinates stability support and wind power output within a unified reference generation framework. A continuity preservation mechanism is then developed to suppress transient impacts through phase angle coordination and DC link power correction. Simulation results show that, compared with conventional MPPT + PQC and FSC methods, the proposed strategy mitigates transition induced fluctuations during grid island transitions. RTDS experiments based on a modified Banshee microgrid model further verify that the proposed strategy improves system stability during grid-connected to islanded transition and islanded to grid connected reconnection.
- Open Access
- 15 June 2026
- Published by MDPI AG in Electronics
- Vol. 15 (12) , 2640
Multiagent Multilayer Control Strategy for Microgrid Clusters with Cross-Coordinated Control and Conflict Coordination
To address fault-induced boundary variations and conflicting commands among heterogeneous controllers in microgrid clusters with high distributed generation penetration, this paper proposes a multilayer multiagent control strategy based on cross-coordinated multiagent control and conflict coordination. The method uses a hierarchical distributed hybrid architecture. Local grid-forming (GFM) energy storage and photovoltaic (PV) converters provide autonomous voltage source support, microgrid coordination controllers generate distributed candidate commands, and the system-level coordination controller performs event-triggered arbitration. Unlike consensus-based cooperative control with fixed exchanged variables, the proposed method enables overlapping supervisory authority, weighted command fusion, explicit conflict classification, and feasible command projection under resource, state-of-charge (SOC), ramping, and load priority constraints. Direction, capacity, and objective conflicts are resolved through system-level arbitration, which converts multiple candidate commands into a single executable command. Comparative simulations show that the proposed method reduces frequency and voltage deviations, shortens power recovery time, improves SOC balancing among energy storage units, and enhances constrained hydropower coordination compared with conventional droop control and one-to-one hierarchical control. These results verify its effectiveness in improving dynamic stability and coordinated support capability in microgrid clusters.
- 15 June 2026
- Published by MDPI AG in Electronics
- Vol. 15 (12) , 2640
Open AccessMultiagent Multilayer Control Strategy for Microgrid Clusters with Cross-Coordinated Control and Conflict Coordination
To address fault-induced boundary variations and conflicting commands among heterogeneous controllers in microgrid clusters with high distributed generation penetration, this paper proposes a multilayer multiagent control strategy based on cross-coordinated multiagent control and conflict coordination. The method uses a hierarchical distributed hybrid architecture. Local grid-forming (GFM) energy storage and photovoltaic (PV) converters provide autonomous voltage source support, microgrid coordination controllers generate distributed candidate commands, and the system-level coordination controller performs event-triggered arbitration. Unlike consensus-based cooperative control with fixed exchanged variables, the proposed method enables overlapping supervisory authority, weighted command fusion, explicit conflict classification, and feasible command projection under resource, state-of-charge (SOC), ramping, and load priority constraints. Direction, capacity, and objective conflicts are resolved through system-level arbitration, which converts multiple candidate commands into a single executable command. Comparative simulations show that the proposed method reduces frequency and voltage deviations, shortens power recovery time, improves SOC balancing among energy storage units, and enhances constrained hydropower coordination compared with conventional droop control and one-to-one hierarchical control. These results verify its effectiveness in improving dynamic stability and coordinated support capability in microgrid clusters.
- Open Access
- 1 June 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (11) , 5576
Coordinated Capacity and Siting of ESSs in Multi-Level Microgrid Clusters
With the large-scale integration of distributed PV, wind power, small hydropower, ESSs, and flexible loads, microgrid clusters exhibit stronger coupling across multiple voltage levels and more complex dynamic interactions. Existing ESS allocation methods mainly focus on economy or total capacity, but insufficiently distinguish the stability support functions of ESSs at the station, feeder, and distribution transformer area levels. To address this issue, this paper proposes a coordinated capacity and siting allocation method for ESSs in multi-voltage level microgrid clusters. The proposed method quantifies the effects of transformers, feeder switches, and power electronic interfaces on disturbance propagation, optimizes station-level and feeder-level ESS capacities, and determines distribution transformer area-level ESS siting according to voltage sensitivity, recovery capability, and stability margin. Simulation results under PV fluctuation, load disturbance, external grid disturbance, and local islanding verify that the proposed method improves voltage recovery, power support, and operational stability while supporting renewable energy utilization, storage resource efficiency, and resilient clean power supply.
- 1 June 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (11) , 5576
Open AccessCoordinated Capacity and Siting of ESSs in Multi-Level Microgrid Clusters
With the large-scale integration of distributed PV, wind power, small hydropower, ESSs, and flexible loads, microgrid clusters exhibit stronger coupling across multiple voltage levels and more complex dynamic interactions. Existing ESS allocation methods mainly focus on economy or total capacity, but insufficiently distinguish the stability support functions of ESSs at the station, feeder, and distribution transformer area levels. To address this issue, this paper proposes a coordinated capacity and siting allocation method for ESSs in multi-voltage level microgrid clusters. The proposed method quantifies the effects of transformers, feeder switches, and power electronic interfaces on disturbance propagation, optimizes station-level and feeder-level ESS capacities, and determines distribution transformer area-level ESS siting according to voltage sensitivity, recovery capability, and stability margin. Simulation results under PV fluctuation, load disturbance, external grid disturbance, and local islanding verify that the proposed method improves voltage recovery, power support, and operational stability while supporting renewable energy utilization, storage resource efficiency, and resilient clean power supply.