Wenjun Han
Wenjun Han has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Lei Shang
Wuhan University
2 shared publications - Runsheng Zheng
School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
2 shared publications - Song Zhang
Electric Power Research Institute of Guizhou Power Grid Co., Ltd., Guiyang 550002, China
2 shared publications - Chang Xu
Guizhou Power Grid Co., Ltd., Guiyang 550001, China
1 shared publication - Hongyan He
Guizhou Power Grid Co., Ltd., Guiyang 550001, China
1 shared publication - Xinyu You
Electric Power Research Institute of Guizhou Power Grid Co., Ltd., Guiyang 550002, China
1 shared publication
Latest Publications
- Open Access
- 1 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (15) , 3406
Constraint-Aware Predictive Energy Coordination of Multiple Energy-Storage Converters for DC Bus Stabilization
Direct current (DC) bus voltage stability in grid-connected microgrids with multiple energy-storage converter branches is governed by the coupled dynamics of photovoltaic generation, heterogeneous battery storage, and the grid-connected inverter. Conventional independent and droop control methods allocate branch power mainly from local voltage or state-of-charge information, and therefore cannot fully account for converter limits, battery condition, or inverter current admissibility. This paper proposes a constraint-aware predictive energy coordination (CAPEC) method for DC bus stabilization. A DC bus energy model with variable losses is combined with one-step disturbance prediction and a safety governor that allocates storage power according to state of charge (SOC), state of health (SOH), power reserve, thermal margin, current capability, and ramp limits. The grid-connected inverter is treated as a constrained energy regulation path with active power saturation and antiwindup correction. Small-signal and energy function analyses show that CAPEC increases equivalent DC bus damping and yields bounded voltage recovery for feasible references and bounded prediction errors. MATLAB R2023b studies for combined photovoltaic and load variation, grid interface disturbance, and heterogeneous storage conditions show that CAPEC limits the maximum voltage deviation to 2.86 to 6.35 V. A reduced power laboratory experiment further verifies the Case B breaker disturbance and confirms stable DC bus behavior during unplanned grid interface switching.
- 1 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (15) , 3406
Open AccessConstraint-Aware Predictive Energy Coordination of Multiple Energy-Storage Converters for DC Bus Stabilization
Direct current (DC) bus voltage stability in grid-connected microgrids with multiple energy-storage converter branches is governed by the coupled dynamics of photovoltaic generation, heterogeneous battery storage, and the grid-connected inverter. Conventional independent and droop control methods allocate branch power mainly from local voltage or state-of-charge information, and therefore cannot fully account for converter limits, battery condition, or inverter current admissibility. This paper proposes a constraint-aware predictive energy coordination (CAPEC) method for DC bus stabilization. A DC bus energy model with variable losses is combined with one-step disturbance prediction and a safety governor that allocates storage power according to state of charge (SOC), state of health (SOH), power reserve, thermal margin, current capability, and ramp limits. The grid-connected inverter is treated as a constrained energy regulation path with active power saturation and antiwindup correction. Small-signal and energy function analyses show that CAPEC increases equivalent DC bus damping and yields bounded voltage recovery for feasible references and bounded prediction errors. MATLAB R2023b studies for combined photovoltaic and load variation, grid interface disturbance, and heterogeneous storage conditions show that CAPEC limits the maximum voltage deviation to 2.86 to 6.35 V. A reduced power laboratory experiment further verifies the Case B breaker disturbance and confirms stable DC bus behavior during unplanned grid interface switching.
- Open Access
- 15 June 2026
- Published by MDPI AG in Electronics
- Vol. 15 (12) , 2643
Unified DFIG Control Strategy for Stability Support and Coordinated Power Export in Microgrid Clusters
This paper investigates AC microgrid clusters with high penetration of DFIG-based wind power. Conventional separated control of wind power output and stability support may cause abrupt power command variations during transitions between grid-connected and islanded operating modes, thereby aggravating system power imbalance. To address this issue, a unified DFIG control strategy is proposed in which an operating objective coordination factor continuously coordinates stability support and wind power output within a unified reference generation framework. A continuity preservation mechanism is then developed to suppress transient impacts through phase angle coordination and DC link power correction. Simulation results show that, compared with conventional MPPT + PQC and FSC methods, the proposed strategy mitigates transition induced fluctuations during grid island transitions. RTDS experiments based on a modified Banshee microgrid model further verify that the proposed strategy improves system stability during grid-connected to islanded transition and islanded to grid connected reconnection.
- 15 June 2026
- Published by MDPI AG in Electronics
- Vol. 15 (12) , 2643
Open AccessUnified DFIG Control Strategy for Stability Support and Coordinated Power Export in Microgrid Clusters
This paper investigates AC microgrid clusters with high penetration of DFIG-based wind power. Conventional separated control of wind power output and stability support may cause abrupt power command variations during transitions between grid-connected and islanded operating modes, thereby aggravating system power imbalance. To address this issue, a unified DFIG control strategy is proposed in which an operating objective coordination factor continuously coordinates stability support and wind power output within a unified reference generation framework. A continuity preservation mechanism is then developed to suppress transient impacts through phase angle coordination and DC link power correction. Simulation results show that, compared with conventional MPPT + PQC and FSC methods, the proposed strategy mitigates transition induced fluctuations during grid island transitions. RTDS experiments based on a modified Banshee microgrid model further verify that the proposed strategy improves system stability during grid-connected to islanded transition and islanded to grid connected reconnection.