Chang Xu
Chang Xu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Lei Shang
Wuhan University
2 shared publications - Runsheng Zheng
School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
2 shared publications - Song Zhang
Electric Power Research Institute of Guizhou Power Grid Co., Ltd., Guiyang 550002, China
2 shared publications - Mingjun He
Electric Power Research Institute of Guizhou Power Grid Co., Ltd., Guiyang 550002, China
1 shared publication - Wenjun Han
Guizhou Power Grid Co., Ltd., Guiyang 550001, China
1 shared publication - Xinyu You
Electric Power Research Institute of Guizhou Power Grid Co., Ltd., Guiyang 550002, China
1 shared publication
Latest Publications
- Open Access
- 1 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (15) , 3406
Constraint-Aware Predictive Energy Coordination of Multiple Energy-Storage Converters for DC Bus Stabilization
Direct current (DC) bus voltage stability in grid-connected microgrids with multiple energy-storage converter branches is governed by the coupled dynamics of photovoltaic generation, heterogeneous battery storage, and the grid-connected inverter. Conventional independent and droop control methods allocate branch power mainly from local voltage or state-of-charge information, and therefore cannot fully account for converter limits, battery condition, or inverter current admissibility. This paper proposes a constraint-aware predictive energy coordination (CAPEC) method for DC bus stabilization. A DC bus energy model with variable losses is combined with one-step disturbance prediction and a safety governor that allocates storage power according to state of charge (SOC), state of health (SOH), power reserve, thermal margin, current capability, and ramp limits. The grid-connected inverter is treated as a constrained energy regulation path with active power saturation and antiwindup correction. Small-signal and energy function analyses show that CAPEC increases equivalent DC bus damping and yields bounded voltage recovery for feasible references and bounded prediction errors. MATLAB R2023b studies for combined photovoltaic and load variation, grid interface disturbance, and heterogeneous storage conditions show that CAPEC limits the maximum voltage deviation to 2.86 to 6.35 V. A reduced power laboratory experiment further verifies the Case B breaker disturbance and confirms stable DC bus behavior during unplanned grid interface switching.
- 1 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (15) , 3406
Open AccessConstraint-Aware Predictive Energy Coordination of Multiple Energy-Storage Converters for DC Bus Stabilization
Direct current (DC) bus voltage stability in grid-connected microgrids with multiple energy-storage converter branches is governed by the coupled dynamics of photovoltaic generation, heterogeneous battery storage, and the grid-connected inverter. Conventional independent and droop control methods allocate branch power mainly from local voltage or state-of-charge information, and therefore cannot fully account for converter limits, battery condition, or inverter current admissibility. This paper proposes a constraint-aware predictive energy coordination (CAPEC) method for DC bus stabilization. A DC bus energy model with variable losses is combined with one-step disturbance prediction and a safety governor that allocates storage power according to state of charge (SOC), state of health (SOH), power reserve, thermal margin, current capability, and ramp limits. The grid-connected inverter is treated as a constrained energy regulation path with active power saturation and antiwindup correction. Small-signal and energy function analyses show that CAPEC increases equivalent DC bus damping and yields bounded voltage recovery for feasible references and bounded prediction errors. MATLAB R2023b studies for combined photovoltaic and load variation, grid interface disturbance, and heterogeneous storage conditions show that CAPEC limits the maximum voltage deviation to 2.86 to 6.35 V. A reduced power laboratory experiment further verifies the Case B breaker disturbance and confirms stable DC bus behavior during unplanned grid interface switching.
- Open Access
- 1 June 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (11) , 5576
Coordinated Capacity and Siting of ESSs in Multi-Level Microgrid Clusters
With the large-scale integration of distributed PV, wind power, small hydropower, ESSs, and flexible loads, microgrid clusters exhibit stronger coupling across multiple voltage levels and more complex dynamic interactions. Existing ESS allocation methods mainly focus on economy or total capacity, but insufficiently distinguish the stability support functions of ESSs at the station, feeder, and distribution transformer area levels. To address this issue, this paper proposes a coordinated capacity and siting allocation method for ESSs in multi-voltage level microgrid clusters. The proposed method quantifies the effects of transformers, feeder switches, and power electronic interfaces on disturbance propagation, optimizes station-level and feeder-level ESS capacities, and determines distribution transformer area-level ESS siting according to voltage sensitivity, recovery capability, and stability margin. Simulation results under PV fluctuation, load disturbance, external grid disturbance, and local islanding verify that the proposed method improves voltage recovery, power support, and operational stability while supporting renewable energy utilization, storage resource efficiency, and resilient clean power supply.
- 1 June 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (11) , 5576
Open AccessCoordinated Capacity and Siting of ESSs in Multi-Level Microgrid Clusters
With the large-scale integration of distributed PV, wind power, small hydropower, ESSs, and flexible loads, microgrid clusters exhibit stronger coupling across multiple voltage levels and more complex dynamic interactions. Existing ESS allocation methods mainly focus on economy or total capacity, but insufficiently distinguish the stability support functions of ESSs at the station, feeder, and distribution transformer area levels. To address this issue, this paper proposes a coordinated capacity and siting allocation method for ESSs in multi-voltage level microgrid clusters. The proposed method quantifies the effects of transformers, feeder switches, and power electronic interfaces on disturbance propagation, optimizes station-level and feeder-level ESS capacities, and determines distribution transformer area-level ESS siting according to voltage sensitivity, recovery capability, and stability margin. Simulation results under PV fluctuation, load disturbance, external grid disturbance, and local islanding verify that the proposed method improves voltage recovery, power support, and operational stability while supporting renewable energy utilization, storage resource efficiency, and resilient clean power supply.