HCHakima Cherif

Hakima Cherif

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hakima Cherif has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Time-Frequency Scalograms of Deep Learning-Based Partial Discharge Classification in Air-Insulated Switchgear Using UHF Detection

    by Hakima Cherif, Ciptian Weried Priananda, Hazlee Azil Illias, Chan Jun Qiang, Wong Jee Keen Raymond, Ali Chemsa

    Partial discharge (PD) monitoring is essential for the condition assessment of air-insulated switchgear (AIS). This paper presents an experimental framework that acquires ultra-high-frequency (UHF) PD signals corresponding to four representative insulation defects: corona, surface, floating electrode, and triple junction. The collected signals are transformed into time–frequency representations using the Continuous Wavelet Transform (CWT) and the Wavelet Synchrosqueezing Transform (WSST) with two analytic mother wavelets, namely Amor and Bump. The resulting scalograms are employed as inputs to a convolutional neural network (CNN) for training and are evaluated using 5-fold cross-validation for PD classification. Comparative results show that WSST consistently improves class separability over CWT across both wavelets, where the WSST-Amor configuration achieves the best overall accuracy of 98.02%, surpassing CWT-Amor, WSST-Bump, and CWT-Bump. Compared to traditional phase-resolved partial discharge (PRPD) approaches, which require larger datasets and more complex acquisition setups, the proposed scalogram-based method provides rich feature representations using fewer signals, offering a more practical and efficient pathway for automated PD diagnosis in AIS.


  • Open Access

    A Robust Scalogram-Based Framework for Partial Discharge Diagnosis in Rotating Machine Insulation Using a Hybrid CNN-SE-Transformer Model

    by Ciptian Weried Weried Priananda, Hazlee Illias, Wong Jee Keen Raymond, Jun Qiang Chan, Hakima Cherif, I. Made Yulistya Negara

    Partial discharge (PD) analysis is essential for assessing the insulation condition of high-voltage rotating machines, as undetected defects may lead to severe failures and operational downtime. However, existing PD diagnostic approaches often rely on phase-resolved measurements or lack robustness under noisy conditions, limiting their applicability in practical environments. This study proposes a robust diagnostic framework integrating waveform-based PD acquisition, wavelet-based scalogram representation, and a hybrid CNN-SE-Transformer deep learning architecture. The proposed approach transforms non-stationary PD signals into time-frequency scalograms using both the Discrete Wavelet Transform (DWT) and Continuous Wavelet Transform (CWT), enabling enhanced feature representation. The hybrid model combines CNN-based local feature extraction, squeeze-and-excitation attention, and transformer-based global feature modeling. The framework is evaluated using a balanced dataset of six PD defect types under both clean and noisy conditions with a modified five-fold cross-validation strategy. Under clean conditions, the proposed model achieves a maximum classification accuracy of 97.25\% using CWT scalograms, outperforming conventional CNN and CNN-SE models. Robustness evaluation under various artificial noise scenarios further demonstrates that the proposed method maintains stable performance, with CWT-based representations providing superior resilience compared to raw signals and DWT scalograms. Compared to conventional PRPD approaches requiring phase synchronization and specialized instrumentation, the proposed framework offers a simpler yet effective alternative for practical PD-based condition monitoring in high-voltage rotating machines.