MOMohamed Sherif Omar

Mohamed Sherif Omar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohamed Sherif Omar has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effects of scanner type and prosthesis design–luting protocol combinations on the passive fit of interim implant‐supported complete‐arch fixed dental prostheses

    by Daizo Ishiguro, Mohamed Sherif Omar, Wei‐Shao Lin, Toshiki Nagai

    Purpose: To evaluate the effects of scanner type and prosthesis design–luting protocol combinations on the passive fit of interim implant‐supported complete‐arch fixed dental prostheses (ISCFDPs) fabricated using a non‐calibrated splinting grammetry system (OptiSplint). The null hypothesis was that scanner type and prosthesis design–luting protocol combinations would not affect the passive fit of interim ISCFDPs. Materials and Methods: This in vitro 2 × 3 factorial study utilized a maxillary edentulous FP‐3 master cast with 4 multiunit abutment (MUA) analogs. Extraoral scans of the OptiSplint assembly were obtained using either an intraoral scanner (IOS‐OptiSplint) or a laboratory scanner (Lab‐OptiSplint). Each scanning method was combined with each of the three prosthesis design–luting protocol combinations: (1) Ti‐base with freehand cementation, (2) Ti‐base cementation on a verification cast, and (3) Direct‐to‐MUA design, resulting in six experimental groups ( n = 10 per group; N = 60). All prostheses were milled from pre‐polymerized polymethylmethacrylate (PMMA) pucks using a five‐axis milling unit. All PMMA ISCFDPs were evaluated for passive fit on the master cast using the screw‐resistance test by two calibrated examiners, with discrepancies resolved by a third. Misfit was determined when incomplete seating or abnormal resistance was detected during sequential screw tightening. Inter‐examiner reliability was assessed using Cohen's kappa, and misfit rates were compared via Fisher's exact tests ( α = 0.05). Results: Inter‐examiner agreement was excellent (98%; κ = 0.95). Laboratory scanning achieved complete passive fit across all three prosthesis design–luting protocol combinations. With the IOS workflow, Ti‐base on Cast demonstrated 0% misfit, Ti‐base Freehand exhibited 30% misfit, and Direct‐to‐MUA demonstrated 100% misfit. Group 3 exhibited a significantly higher misfit frequency than all other groups ( p < 0.001), whereas no other pairwise comparisons were significant. Conclusion: Laboratory scanning of a non‐calibrated splinting grammetry system was associated with consistently complete passive fit across all groups. It may provide a predictable approach for achieving passive fit in complete‐arch interim prostheses. Extraoral scanning with an intraoral scanner yielded variable results, underscoring the value of verification‐cast cementation when using Ti‐bases. Within the limitations of this study, the results suggest that Direct‐to‐MUA workflows may require laboratory‐based scanning when using the evaluated systems.

  • Open Access

    Virtual articulation using sequential mandibular intraoral scans and computational functional rotation reference determination-Proof-of-concept.

    by Mohamed Sherif Omar, Chao-Chieh Yang, Dean Morton, Wei-Shao Lin

    Virtual articulators require accurate spatial orientation of digital casts for meaningful occlusal analysis during prosthesis design. Current methods for establishing this orientation rely on facial scanning, cone-beam computed tomography, electronic jaw tracking, or arbitrary population-based values. This proof-of-concept technique presents a computational method for determining a functional rotation reference from sequential mandibular intraoral scans captured at controlled opening increments using leaf gauges. The algorithm identifies regions exhibiting minimal translation during jaw opening through systematic grid search within anatomically defined boundaries posterior and superior to the molar positions. Points demonstrating negligible displacement while surrounding structures rotate lie geometrically on or near a rotation axis; a best fit line through their distribution establishes the functional rotation reference. This reference is then transformed to align with the intercondylar axis coordinates of the virtual articulator for digital cast mounting. Forward validation demonstrated root mean square deviations averaging 0.14 mm between simulated and actual scan positions. The technique was implemented for multiple virtual articulator systems including Denar Mark 330, Artex CR, and Stratos 300. This method enables patient-specific virtual articulation using only standard intraoral scanning equipment and leaf gauges, eliminating dependence on supplementary registration hardware.