Phase relaxed localized excitation pulses for inner volume fast spin echo imaging
Open Access
- 9 October 2015
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 76 (3) , 848-861
Abstract
Purpose: To design multidimensional spatially selective radiofrequency (RF) pulses for inner volume imaging (IVI) with three‐dimensional (3D) fast spin echo (FSE) sequences. Enhanced background suppression is achieved by exploiting particular signal properties of FSE sequences.Theory and Methods: The CPMG condition dictates that echo amplitudes will rapidly decrease if a 90° phase difference between excitation and refocusing pulses is not present, and refocusing flip angles are not precisely 180°. This mechanism is proposed as a means for generating additional background suppression for spatially selective excitation, by biasing residual excitation errors toward violating the CPMG condition. 3D RF pulses were designed using this method with a 3D spherical spiral trajectory, under‐sampled by factor 5.6 for an eight‐channel PTx system, at 3 Tesla.Results: 3D‐FSE IVI with pulse durations of approximately 12 ms was demonstrated in phantoms and for T2‐weighted brain imaging in vivo. Good image quality was obtained, with mean background suppression factors of 103 and 82 ± 6 in phantoms and in vivo, respectively.Conclusion: Inner Volume Imaging with 3D‐FSE has been demonstrated in vivo with tailored 3D‐RF pulses. The proposed design methods are also applicable to 2D pulses. Magn Reson Med 76:848–861, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in MedicineKeywords
Funding Information
- EPSRC (EP/L00531X/1, EP/H046410/1)
- Medical Research Council (MR/K006355/1)
- The National Institute for Health Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust
This publication has 43 references indexed in Scilit:
- Gradient system characterization by impulse response measurements with a dynamic field cameraMagnetic Resonance in Medicine, 2012
- VERSE‐guided numerical RF pulse design: A fast method for peak RF power controlMagnetic Resonance in Medicine, 2011
- Improved large tip angle parallel transmission pulse design through a perturbation analysis of the bloch equationMagnetic Resonance in Medicine, 2011
- Multi-contrast high spatial resolution black blood inner volume three-dimensional fast spin echo MR imaging in peripheral vein bypass graftsThe International Journal of Cardiovascular Imaging, 2010
- Time‐optimal design for multidimensional and parallel transmit variable‐rate selective excitationMagnetic Resonance in Medicine, 2009
- A fast method for designing time-optimal gradient waveforms for arbitrary k-space trajectoriesIEEE Transactions on Medical Imaging, 2008
- Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channelsMagnetic Resonance in Medicine, 2008
- High‐resolution peripheral vein bypass graft wall studies using high sampling efficiency inner volume 3D FSEMagnetic Resonance in Medicine, 2008
- A linear class of large-tip-angle selective excitation pulsesJournal of Magnetic Resonance (1969), 1989
- A k-space analysis of small-tip-angle excitationJournal of Magnetic Resonance (1969), 1989