Determination and validation of the initial beam parameters of Elekta Agility collimator head by Monte Carlo simulations
Authors:
- 18 July 2022
- journal article
- research article
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 45 (3) , 889-899
Abstract
The availability of geometrical, physical, and initial beam parameters for Monte Carlo (MC) simulations of the Elekta Agility collimator head has become very difficult due to the proprietary nature of this data. This study presents strategies to independently determine the geometrical and physical properties of the components and initial beam parameters of the Agility collimator head for full beam simulations and postulates a benchmarking process using the EGSnrc MC toolkit. Target material of W (90%) and Re (10%) of 0.09 cm thickness, flattening filter of 1.77 cm thick stainless steel placed on 0.5 cm Al disc, and primary and secondary collimators of Tungsten alloy have been found to best fit the Agility head. The initial beam energy of 6.0 MeV with a radial distribution given as full-width half maxima (FWHM) of 0.301 cm (crossline) × 0.201 cm (inline) for 6 MV beam with a mean angular spread of 1.34° has been found best fitting the model. Variations of 0.29% and 0.59% have been noted in the measured and calculated values of TPR20,10 and D10 respectively. More than 90% dose points for all simulations passed the 2D gamma criteria of 3% DD, 3 mm DTA. This MC model of the Agility head can be used for dose calculation and validation of advanced treatment techniques.Keywords
This publication has 26 references indexed in Scilit:
- EP-1462: Monte Carlo simulation of the Elekta Agility linear aceleratorRadiotherapy and Oncology, 2015
- Monte Carlo linear accelerator simulation of megavoltage photon beams: Independent determination of initial beam parametersMedical Physics, 2011
- Simulation of a 6 MV Elekta Precise Linac photon beam using GATE/GEANT4Physics in Medicine & Biology, 2011
- On Monte Carlo modeling of megavoltage photon beams: A revisited study on the sensitivity of beam parametersMedical Physics, 2010
- Effects of collimator backscatter in an Elekta linac by Monte Carlo simulationAustralasian Physics & Engineering Sciences in Medicine, 2009
- Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x‐ray beamsMedical Physics, 2009
- Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parametersMedical Physics, 2002
- Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM codeMedical Physics, 2002
- Comparison of measured and Monte Carlo calculated dose distributions from the NRC linacMedical Physics, 2000