Nataliya Y. Kashtanova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nataliya Y. Kashtanova has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Anton V. Hardin
S.S. Yudin City Clinical Hospital, Moscow Department of Health, Moscow 129090, Russia
2 shared publications - Evgenii V. Kopeykin
S.S. Yudin City Clinical Hospital, Moscow Department of Health, Moscow 129090, Russia
2 shared publications - Maria S. Gribkova
Multidisciplinary Medical Center of the Bank of Russia, Moscow 117647, Russia
2 shared publications - Marina Igorevna Sekacheva
Sechenov First Moscow State Medical University (Sechenov University)
2 shared publications - Umamat M. Magomedova
S.S. Yudin City Clinical Hospital, Moscow Department of Health, Moscow 129090, Russia
2 shared publications - Valentin A. Nechaev
S.S. Yudin City Clinical Hospital, Moscow Department of Health, Moscow 129090, Russia
2 shared publications
Latest Publications
- Open Access
- 1 November 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (21) , 2778
Diagnostic Accuracy of a Multi-Target Artificial Intelligence Service for the Simultaneous Assessment of 16 Pathological Features on Chest and Abdominal CT
Background/Objectives: Chest, abdominal, and pelvic computed tomography (CT) with intravenous contrast is widely used for tumor staging, treatment planning, and therapy monitoring. The integration of artificial intelligence (AI) services is expected to improve diagnostic accuracy across multiple anatomical regions simultaneously. We aimed to evaluate the diagnostic accuracy of a multi-target AI service in detecting 16 pathological features on chest and abdominal CT images. Methods: We conducted a retrospective study using anonymized CT data from an open dataset. A total of 229 CT scans were independently interpreted by four radiologists with more than 5 years of experience and analyzed by the AI service. Sixteen pathological features were assessed. AI errors were classified as minor, intermediate, or clinically significant. Diagnostic accuracy was evaluated using the area under the receiver operating characteristic curve (AUC). Results: Across 229 CT scans, the AI service made 423 errors (11.5% of all evaluated features, n = 3664). False positives accounted for 262 cases (61.9%) and false negatives for 161 (38.1%). Most errors were minor (62.9%) or intermediate (31.7%), while clinically significant errors comprised only 5.4%. The overall AUC of the AI service was 0.88 (95% CI: 0.87–0.89), compared with 0.78–0.81 for radiologists. For clinically significant findings, the AI AUC was 0.90 (95% CI: 0.71–1.00). Diagnostic accuracy was unsatisfactory only for urolithiasis. Conclusions: The multi-target AI service demonstrated high diagnostic accuracy for chest and abdominal CT interpretation, with most errors being clinically negligible; performance was limited for urolithiasis.
- 1 November 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (21) , 2778
Open AccessDiagnostic Accuracy of a Multi-Target Artificial Intelligence Service for the Simultaneous Assessment of 16 Pathological Features on Chest and Abdominal CT
Background/Objectives: Chest, abdominal, and pelvic computed tomography (CT) with intravenous contrast is widely used for tumor staging, treatment planning, and therapy monitoring. The integration of artificial intelligence (AI) services is expected to improve diagnostic accuracy across multiple anatomical regions simultaneously. We aimed to evaluate the diagnostic accuracy of a multi-target AI service in detecting 16 pathological features on chest and abdominal CT images. Methods: We conducted a retrospective study using anonymized CT data from an open dataset. A total of 229 CT scans were independently interpreted by four radiologists with more than 5 years of experience and analyzed by the AI service. Sixteen pathological features were assessed. AI errors were classified as minor, intermediate, or clinically significant. Diagnostic accuracy was evaluated using the area under the receiver operating characteristic curve (AUC). Results: Across 229 CT scans, the AI service made 423 errors (11.5% of all evaluated features, n = 3664). False positives accounted for 262 cases (61.9%) and false negatives for 161 (38.1%). Most errors were minor (62.9%) or intermediate (31.7%), while clinically significant errors comprised only 5.4%. The overall AUC of the AI service was 0.88 (95% CI: 0.87–0.89), compared with 0.78–0.81 for radiologists. For clinically significant findings, the AI AUC was 0.90 (95% CI: 0.71–1.00). Diagnostic accuracy was unsatisfactory only for urolithiasis. Conclusions: The multi-target AI service demonstrated high diagnostic accuracy for chest and abdominal CT interpretation, with most errors being clinically negligible; performance was limited for urolithiasis.
- Open Access
- 29 October 2025
- Published by MDPI AG in Preprints.org
Diagnostic Accuracy of a Multi-Target Artificial Intelligence Service for the Simultaneous Assessment of 16 Pathological Features on Chest and Abdominal CT
Background: Chest, abdominal, and pelvic computed tomography (CT) with intrave-nous contrast is widely used for tumor staging, treatment planning, and therapy mon-itoring. The integration of artificial intelligence (AI) services is expected to improve diagnostic accuracy across multiple anatomical regions simultaneously. Purpose: To evaluate the diagnostic accuracy of a multi-target AI service in detecting 16 pathological features on chest and abdominal CT images. Methods: We conducted a retrospective study using anonymized CT data from an open dataset. A total of 229 CT scans were independently interpreted by four radiologists with more than 5 years of experience and analyzed by the AI service. Sixteen pathological features were assessed. AI errors were classified as minor, intermediate, or clinically significant. Diagnostic accuracy was evaluated using the area under the receiver operating characteristic curve (AUC). Re-sults: Across 229 CT scans, the AI service made 423 errors (11.5% of all evaluated fea-tures, n = 3664). False positives accounted for 262 cases (61.9%) and false negatives for 161 (38.1%). Most errors were minor (62.9%) or intermediate (31.7%), while clinically significant errors comprised only 5.4%. The overall AUC of the AI service was 0.88 (95% CI: 0.87–0.89), compared with 0.78–0.81 for radiologists. For clinically significant find-ings, the AI AUC was 0.90 (95% CI: 0.71–1.00). Diagnostic accuracy was unsatisfactory only for urolithiasis. Conclusions: The multi-target AI service demonstrated high di-agnostic accuracy for chest and abdominal CT interpretation, with most errors being clinically negligible; performance was limited for urolithiasis.
- 29 October 2025
- Published by MDPI AG in Preprints.org
Open AccessDiagnostic Accuracy of a Multi-Target Artificial Intelligence Service for the Simultaneous Assessment of 16 Pathological Features on Chest and Abdominal CT
Background: Chest, abdominal, and pelvic computed tomography (CT) with intrave-nous contrast is widely used for tumor staging, treatment planning, and therapy mon-itoring. The integration of artificial intelligence (AI) services is expected to improve diagnostic accuracy across multiple anatomical regions simultaneously. Purpose: To evaluate the diagnostic accuracy of a multi-target AI service in detecting 16 pathological features on chest and abdominal CT images. Methods: We conducted a retrospective study using anonymized CT data from an open dataset. A total of 229 CT scans were independently interpreted by four radiologists with more than 5 years of experience and analyzed by the AI service. Sixteen pathological features were assessed. AI errors were classified as minor, intermediate, or clinically significant. Diagnostic accuracy was evaluated using the area under the receiver operating characteristic curve (AUC). Re-sults: Across 229 CT scans, the AI service made 423 errors (11.5% of all evaluated fea-tures, n = 3664). False positives accounted for 262 cases (61.9%) and false negatives for 161 (38.1%). Most errors were minor (62.9%) or intermediate (31.7%), while clinically significant errors comprised only 5.4%. The overall AUC of the AI service was 0.88 (95% CI: 0.87–0.89), compared with 0.78–0.81 for radiologists. For clinically significant find-ings, the AI AUC was 0.90 (95% CI: 0.71–1.00). Diagnostic accuracy was unsatisfactory only for urolithiasis. Conclusions: The multi-target AI service demonstrated high di-agnostic accuracy for chest and abdominal CT interpretation, with most errors being clinically negligible; performance was limited for urolithiasis.
- 10 October 2020
- Published by Vidar, Ltd. in Medical Visualization
- Vol. 24 (3) , 88-106
Techniques of left atrial appendage tomography for planning intervention treatment of atrial fibrillation
Due to intracardiac circulatory changes atrial fibrillation creates conditions for thrombus formation in the left atrial appendage (LAA). The presence of thrombus in LAA is poor prognostic factor of subsequent cardiovascular events. It is the source of up to 64% of ischemic stroke cases, and concomitant anticoagulant therapy leads to a high frequency of hemorrhagic conversion. For patient with symptomatic and drug-refractory arrhythmia is recommended surgical rhythm correction or electrical cardioversion. There is a high risk of cardioembolic stroke during the intervention, so it is necessary to exclude LAA thrombosis at pre-operation stage. The main method of LAA visualization is transesophageal echocardiography, but today computed tomography and, less, magnetic resonance tomography become important. The purpose of this review is to analyze the possibilities of each visualisation technique and their role in the diagnostic algorithm when examining patients before catheter ablation of atrial fibrillation sources.
- 10 October 2020
- Published by Vidar, Ltd. in Medical Visualization
- Vol. 24 (3) , 88-106
Techniques of left atrial appendage tomography for planning intervention treatment of atrial fibrillation
Due to intracardiac circulatory changes atrial fibrillation creates conditions for thrombus formation in the left atrial appendage (LAA). The presence of thrombus in LAA is poor prognostic factor of subsequent cardiovascular events. It is the source of up to 64% of ischemic stroke cases, and concomitant anticoagulant therapy leads to a high frequency of hemorrhagic conversion. For patient with symptomatic and drug-refractory arrhythmia is recommended surgical rhythm correction or electrical cardioversion. There is a high risk of cardioembolic stroke during the intervention, so it is necessary to exclude LAA thrombosis at pre-operation stage. The main method of LAA visualization is transesophageal echocardiography, but today computed tomography and, less, magnetic resonance tomography become important. The purpose of this review is to analyze the possibilities of each visualisation technique and their role in the diagnostic algorithm when examining patients before catheter ablation of atrial fibrillation sources.