JLJonathan Larochelle

Jonathan Larochelle

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jonathan Larochelle has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The impact of EEG preprocessing parameters on ultra‐low‐power seizure detection

    by Patrick Reisinger, Jonathan Larochelle, Ciamak Abkai, Sotirios Kalousios, Nico Zabler, Matthias Dümpelmann, Andreas Schulze‐Bonhage, Peter Woias, Laura Comella

    Objective: Closed‐loop neurostimulation is a promising treatment for drug‐resistant focal epilepsy. A major challenge is fast and reliable seizure detection via electroencephalography (EEG). Although many approaches have been published, they often lack statistical power and practical utility. The use of various EEG preprocessing parameters and performance metrics hampers comparability. Additionally, the critical issue of energy consumption for an application in medical devices is rarely considered. Addressing these points, we present a systematic analysis of the impact of EEG preprocessing parameters on seizure detection performance and energy consumption, using one to four EEG channels. Methods: We analyzed in 145 patients with focal epilepsy the impact of different sampling rates, window sizes, digital resolutions, and number of EEG channels on seizure detection performance and energy consumption. Focusing on clinically relevant, event‐based metrics, we evaluated seizure detection performance of a state‐of‐the‐art convolutional neural network (CNN) via the Seizure Community Open‐Source Research Evaluation (SzCORE) framework. Statistical relevance of parameter changes was assessed using linear mixed‐effects models. Energy consumption was analyzed using an ultra‐low‐power microcontroller. Results: Reducing the sampling rate from 256 to 64 Hz decreased sensitivity ( p = .015) and false detections per hour (FD/h; p = .002). Larger windows reduced FD/h between 1 s and all other sizes (all p < .001). Lower digital resolution decreased sensitivity between 16 and 8 bits ( p = .007). Using one EEG channel instead of four decreased sensitivity ( p < .001) and increased detection delay ( p = .020), but also reduced FD/h ( p = .005). Reducing the sampling rate to 64 Hz lowered CNN energy consumption from 49.15 to 17.26 μJ/s, and using one channel reduced it from 79.04 to 31.63 μJ/s. Significance: This study provides guidance on choosing EEG preprocessing parameters for innovative developments of closed‐loop neurostimulation devices to further advance the treatment of drug‐resistant focal epilepsy.


  • Open Access

    Memory optimized random forest classifier for EEG seizure detection in implantable monitoring and closed-loop neurostimulation devices

    by Sotirios Kalousios, Jonathan Larochelle, Nicolas Zabler, Nico Locker, Peter Woias, Laura Maria Comella, Andreas Schulze-Bonhage, Matthias Dümpelmann

    Objective. Up to one third of epilepsy patients do not achieve satisfactory seizure control and may benefit from implantable devices for responsive neurostimulation or online seizure monitoring. Beyond energy efficiency, the limited memory capacity in these devices, imposes significant constraints to algorithmic design of seizure detection models. This study aims to evaluate the performance of cross-patient random forest (RF) models optimized for low-power microcontroller applications by assessing various channel integration strategies and measuring their memory requirements. Approach. Fifty patients undergoing electroencephalographic monitoring with 362 seizures were included in the analysis, with approximately one hour of signal for each seizure. One central and four peripheral electrodes over the epileptogenic focus were selected to resemble the layout of a novel neurostimulation device. Fifteen features were extracted from 2 s non-overlapping segments. RF models comprised either 500 or 125 trees, with varying depths. Three early channel integration (EI) strategies were compared with late integration (LI), using three channel fusion methods. A leave-one-patient-out cross-validation approach was used for evaluation, and memory requirements, alongside with inference energy and latency for 8-bit integer and 32-bit floating point models were computed on a microcontroller. Main results. The performance of EI feature sorting and LI were comparable. LI was favored by the 32-bit floating point format and more complex models, with the median channel fusion achieving a median area under the receiver operating characteristic curve score of 0.925. Feature sorting performed best with medium-sized models and was largely unaffected by the 8-bit integer format. Following causal output post-processing, false stimulations per hour were reduced to 5.5 at 100% sensitivity and fell below 3 at ∼ 80% sensitivity. Significance. Our findings suggest that RF models with minimal energy and memory requirements can achieve state-of-the-art performance, making them well-suited for embedded applications in implantable devices. The complex interplay of the investigated factors is critical to performance, and along hardware specifications, should guide algorithmic design.


  • Open Access

    The impact of EEG preprocessing parameters on ultra-low-power seizure detection

    by Patrick Reisinger, Jonathan Larochelle, Ciamak Abkai, Sotirios Kalousios, Nico Zabler, Matthias Duempelmann, Andreas Schulze-Bonhage, Peter Woias, Laura Comella

    Objective: Closed-loop neurostimulation is a promising treatment for drug-resistant focal epilepsy. A major challenge is fast and reliable seizure detection via electroencephalography (EEG). While many approaches have been published, they often lack statistical power and practical utility. The use of various EEG preprocessing parameters and performance metrics hampers comparability. Additionally, the critical issue of energy consumption for an application in medical devices is rarely considered. Addressing these points, we present a systematic analysis on the impact of EEG preprocessing parameters on seizure detection performance and energy consumption, using one to four EEG channels. Methods: We analyzed in 145 patients with focal epilepsy the impact of different sampling rates, window sizes, digital resolutions and number of EEG channels on seizure detection performance and energy consumption. Focusing on clinically relevant, event-based metrics, we evaluated seizure detection performance of a state-of-the-art convolutional neural network (CNN) via the Seizure Community Open-Source Research Evaluation (SzCORE) framework. Statistical relevance of parameter changes was assessed using linear mixed-effects models. Energy consumption was analyzed using an ultra-low-power microcontroller. Results: Reducing the sampling rate from 256 to 64 Hz led to a decrease in sensitivity ( p = .015) and false detections per hour (FD/h; p = .002). Larger window sizes reduced sensitivity between 1 and 8 second windows ( p = .033) and FD/h between one second and all other sizes (all p values < .001). Average detection delays increased between one second and 4 and 8 second windows (both p < .01). Lower digital resolutions decreased sensitivity between 16 and 8 bits ( p = .007). Compared to four channels, using only one EEG channel resulted in a decrease in sensitivity ( p < .001) and an increase in the average detection delay ( p = .020), but showed less FD/h ( p = .005). CNN energy consumption decreased from 49.15 to 17.26 µJ/s when the sampling rate was reduced from 256 to 64 Hz. Lowering the number of channels from four to one reduced the CNN energy consumption from 79.04 to 31.63 µJ/s. Significance: This study provides guidance on choosing EEG preprocessing parameters for innovative developments of closed-loop neurostimulation devices to further advance the treatment of drug-resistant focal epilepsy. Key points: A major challenge in closed-loop neurostimulation is fast and reliable seizure detection, ideally with minimal energy consumption. Many published seizure detection approaches are not ready for application and lack statistical power and comparability. The impact of EEG preprocessing parameters was systematically evaluated in 145 patients with focal epilepsy. The chosen window size and number of channels had the strongest impact on seizure detection performance and energy consumption. Our results offer guidance for EEG preprocessing choices to advance the treatment of drug-resistant focal epilepsy.


  • A Low-Power Optical Sensor With Dynamically Adjustable Field of View for Photosynthetically Active Radiation (PAR) Measurement

    by Jonathan Larochelle, Johannes Klueppel, Roy McCormick, Konni Biegert, Laura Maria Comella

    The characterization of light as photosynthetically active radiation (PAR) is crucial for modeling and monitoring plant metabolism and development. Existing intercepted PAR sensing solutions are limited by the requirement to average many below-canopy measurements to account for heterogeneity in the plant canopy, which requires a human operator. In this work, we address this issue by introducing a novel sensing concept to measure the light coming from different areas of the tree canopy with a single sensor by dynamically varying the sensor’s field of view in the zenith and azimuth directions. The sensing system consists of (1) an imaging lens that collects the incoming light, (2) a programmable Liquid-Crystal Display (LCD), which acts as an optical shutter, (3) a diffuser, and (4) the AS7341 multispectral sensor. In this work, the PAR model required to calibrate the sensor is derived and the sensing system is calibrated and characterized. A sensor prototype is then assembled, calibrated, and characterized, achieving competitive performance with a mean average percentage error of 6.78% and a normalized root mean square error of 4.82% on PAR measurements. Tests using a custom LED test sphere show that the sensor has a spatial resolution of 7° and 15° in the θ and ϕ directions, respectively. With a power consumption of 19.54mW mainly attributable to the LCD, our new sensing system could be used for more than two years at one hour of measurements per day, which paves the way towards long-term continuous monitoring of PAR.