Ciamak Abkai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ciamak Abkai has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Schulze-Bonhage
Epilepsy Center, University Medical Center, University of Freiburg, Germany
2 shared publications - Jonathan Larochelle
Department of Microsystems Engineering—IMTEK University of Freiburg Freiburg Germany
2 shared publications - Laura Maria Comella
Institute of Energy Efficient Mobility, Karlsruhe University of Applied Sciences, Karlsruhe, 76133, Germany
2 shared publications - Matthias Dümpelmann
Epilepsy Center Medical Center–University of Freiburg, Faculty of Medicine, University of Freiburg Freiburg Germany
2 shared publications - Nicolas Zabler
Epilepsy Center Faculty of Medicine, Medical Center ‐ University of Freiburg, Member of the ERN EpiCARE Freiburg Germany
2 shared publications - Patrick Reisinger
Precisis GmbH, Research & Development Heidelberg Germany
2 shared publications
Latest Publications
- Open Access
The impact of EEG preprocessing parameters on ultra‐low‐power seizure detection
Objective: Closed‐loop neurostimulation is a promising treatment for drug‐resistant focal epilepsy. A major challenge is fast and reliable seizure detection via electroencephalography (EEG). Although many approaches have been published, they often lack statistical power and practical utility. The use of various EEG preprocessing parameters and performance metrics hampers comparability. Additionally, the critical issue of energy consumption for an application in medical devices is rarely considered. Addressing these points, we present a systematic analysis of the impact of EEG preprocessing parameters on seizure detection performance and energy consumption, using one to four EEG channels. Methods: We analyzed in 145 patients with focal epilepsy the impact of different sampling rates, window sizes, digital resolutions, and number of EEG channels on seizure detection performance and energy consumption. Focusing on clinically relevant, event‐based metrics, we evaluated seizure detection performance of a state‐of‐the‐art convolutional neural network (CNN) via the Seizure Community Open‐Source Research Evaluation (SzCORE) framework. Statistical relevance of parameter changes was assessed using linear mixed‐effects models. Energy consumption was analyzed using an ultra‐low‐power microcontroller. Results: Reducing the sampling rate from 256 to 64 Hz decreased sensitivity ( p = .015) and false detections per hour (FD/h; p = .002). Larger windows reduced FD/h between 1 s and all other sizes (all p < .001). Lower digital resolution decreased sensitivity between 16 and 8 bits ( p = .007). Using one EEG channel instead of four decreased sensitivity ( p < .001) and increased detection delay ( p = .020), but also reduced FD/h ( p = .005). Reducing the sampling rate to 64 Hz lowered CNN energy consumption from 49.15 to 17.26 μJ/s, and using one channel reduced it from 79.04 to 31.63 μJ/s. Significance: This study provides guidance on choosing EEG preprocessing parameters for innovative developments of closed‐loop neurostimulation devices to further advance the treatment of drug‐resistant focal epilepsy.
Open AccessThe impact of EEG preprocessing parameters on ultra‐low‐power seizure detection
Objective: Closed‐loop neurostimulation is a promising treatment for drug‐resistant focal epilepsy. A major challenge is fast and reliable seizure detection via electroencephalography (EEG). Although many approaches have been published, they often lack statistical power and practical utility. The use of various EEG preprocessing parameters and performance metrics hampers comparability. Additionally, the critical issue of energy consumption for an application in medical devices is rarely considered. Addressing these points, we present a systematic analysis of the impact of EEG preprocessing parameters on seizure detection performance and energy consumption, using one to four EEG channels. Methods: We analyzed in 145 patients with focal epilepsy the impact of different sampling rates, window sizes, digital resolutions, and number of EEG channels on seizure detection performance and energy consumption. Focusing on clinically relevant, event‐based metrics, we evaluated seizure detection performance of a state‐of‐the‐art convolutional neural network (CNN) via the Seizure Community Open‐Source Research Evaluation (SzCORE) framework. Statistical relevance of parameter changes was assessed using linear mixed‐effects models. Energy consumption was analyzed using an ultra‐low‐power microcontroller. Results: Reducing the sampling rate from 256 to 64 Hz decreased sensitivity ( p = .015) and false detections per hour (FD/h; p = .002). Larger windows reduced FD/h between 1 s and all other sizes (all p < .001). Lower digital resolution decreased sensitivity between 16 and 8 bits ( p = .007). Using one EEG channel instead of four decreased sensitivity ( p < .001) and increased detection delay ( p = .020), but also reduced FD/h ( p = .005). Reducing the sampling rate to 64 Hz lowered CNN energy consumption from 49.15 to 17.26 μJ/s, and using one channel reduced it from 79.04 to 31.63 μJ/s. Significance: This study provides guidance on choosing EEG preprocessing parameters for innovative developments of closed‐loop neurostimulation devices to further advance the treatment of drug‐resistant focal epilepsy.
- Open Access
The impact of EEG preprocessing parameters on ultra-low-power seizure detection
Objective: Closed-loop neurostimulation is a promising treatment for drug-resistant focal epilepsy. A major challenge is fast and reliable seizure detection via electroencephalography (EEG). While many approaches have been published, they often lack statistical power and practical utility. The use of various EEG preprocessing parameters and performance metrics hampers comparability. Additionally, the critical issue of energy consumption for an application in medical devices is rarely considered. Addressing these points, we present a systematic analysis on the impact of EEG preprocessing parameters on seizure detection performance and energy consumption, using one to four EEG channels. Methods: We analyzed in 145 patients with focal epilepsy the impact of different sampling rates, window sizes, digital resolutions and number of EEG channels on seizure detection performance and energy consumption. Focusing on clinically relevant, event-based metrics, we evaluated seizure detection performance of a state-of-the-art convolutional neural network (CNN) via the Seizure Community Open-Source Research Evaluation (SzCORE) framework. Statistical relevance of parameter changes was assessed using linear mixed-effects models. Energy consumption was analyzed using an ultra-low-power microcontroller. Results: Reducing the sampling rate from 256 to 64 Hz led to a decrease in sensitivity ( p = .015) and false detections per hour (FD/h; p = .002). Larger window sizes reduced sensitivity between 1 and 8 second windows ( p = .033) and FD/h between one second and all other sizes (all p values < .001). Average detection delays increased between one second and 4 and 8 second windows (both p < .01). Lower digital resolutions decreased sensitivity between 16 and 8 bits ( p = .007). Compared to four channels, using only one EEG channel resulted in a decrease in sensitivity ( p < .001) and an increase in the average detection delay ( p = .020), but showed less FD/h ( p = .005). CNN energy consumption decreased from 49.15 to 17.26 µJ/s when the sampling rate was reduced from 256 to 64 Hz. Lowering the number of channels from four to one reduced the CNN energy consumption from 79.04 to 31.63 µJ/s. Significance: This study provides guidance on choosing EEG preprocessing parameters for innovative developments of closed-loop neurostimulation devices to further advance the treatment of drug-resistant focal epilepsy. Key points: A major challenge in closed-loop neurostimulation is fast and reliable seizure detection, ideally with minimal energy consumption. Many published seizure detection approaches are not ready for application and lack statistical power and comparability. The impact of EEG preprocessing parameters was systematically evaluated in 145 patients with focal epilepsy. The chosen window size and number of channels had the strongest impact on seizure detection performance and energy consumption. Our results offer guidance for EEG preprocessing choices to advance the treatment of drug-resistant focal epilepsy.
Open AccessThe impact of EEG preprocessing parameters on ultra-low-power seizure detection
Objective: Closed-loop neurostimulation is a promising treatment for drug-resistant focal epilepsy. A major challenge is fast and reliable seizure detection via electroencephalography (EEG). While many approaches have been published, they often lack statistical power and practical utility. The use of various EEG preprocessing parameters and performance metrics hampers comparability. Additionally, the critical issue of energy consumption for an application in medical devices is rarely considered. Addressing these points, we present a systematic analysis on the impact of EEG preprocessing parameters on seizure detection performance and energy consumption, using one to four EEG channels. Methods: We analyzed in 145 patients with focal epilepsy the impact of different sampling rates, window sizes, digital resolutions and number of EEG channels on seizure detection performance and energy consumption. Focusing on clinically relevant, event-based metrics, we evaluated seizure detection performance of a state-of-the-art convolutional neural network (CNN) via the Seizure Community Open-Source Research Evaluation (SzCORE) framework. Statistical relevance of parameter changes was assessed using linear mixed-effects models. Energy consumption was analyzed using an ultra-low-power microcontroller. Results: Reducing the sampling rate from 256 to 64 Hz led to a decrease in sensitivity ( p = .015) and false detections per hour (FD/h; p = .002). Larger window sizes reduced sensitivity between 1 and 8 second windows ( p = .033) and FD/h between one second and all other sizes (all p values < .001). Average detection delays increased between one second and 4 and 8 second windows (both p < .01). Lower digital resolutions decreased sensitivity between 16 and 8 bits ( p = .007). Compared to four channels, using only one EEG channel resulted in a decrease in sensitivity ( p < .001) and an increase in the average detection delay ( p = .020), but showed less FD/h ( p = .005). CNN energy consumption decreased from 49.15 to 17.26 µJ/s when the sampling rate was reduced from 256 to 64 Hz. Lowering the number of channels from four to one reduced the CNN energy consumption from 79.04 to 31.63 µJ/s. Significance: This study provides guidance on choosing EEG preprocessing parameters for innovative developments of closed-loop neurostimulation devices to further advance the treatment of drug-resistant focal epilepsy. Key points: A major challenge in closed-loop neurostimulation is fast and reliable seizure detection, ideally with minimal energy consumption. Many published seizure detection approaches are not ready for application and lack statistical power and comparability. The impact of EEG preprocessing parameters was systematically evaluated in 145 patients with focal epilepsy. The chosen window size and number of channels had the strongest impact on seizure detection performance and energy consumption. Our results offer guidance for EEG preprocessing choices to advance the treatment of drug-resistant focal epilepsy.
- Open Access
- 1 January 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 7031269
The Effects of Additional Filtration on Image Quality and Radiation Dose in Cone Beam CT: An In Vivo Preliminary Investigation
Purpose. The aim of this study was to investigate the effect of reduced radiation doses on the image quality of cone‐beam computed tomography scans and the suitability of such imaging for orthodontics, oral surgery, dental implantology, periodontology, and endodontology. Materials and Methods. Cone‐beam computed tomography scans of a live patient were performed using seven attenuation filters with increased thickness to decrease the effective radiation dose from 22.4 to 1.8 μSv, and the effects of different radiation doses on image quality were further analysed. Quantitative image quality was calculated using dedicated measures, such as signal and contrast‐to‐noise ratio and sharpness. A panel of five certified raters assessed the cone‐beam computed tomography scans qualitatively. Nine anatomical structures relevant to dentistry were identified, and the overall acceptance was assessed. Results. Linear reduction of the effective radiation dose had a nonlinear effect on image quality. A 5‐fold reduction in the effective dose led to acceptable quantitative and qualitative image quality measures, and the identification rate of dental anatomical structures was 80% or greater. The use of less than 40% of the reference dose was unacceptable for all dental specialties. Conclusions. The ideal radiation dose for specific diagnostic requirements remains a patient‐related and specialty‐related decision that must be made on an individual basis. Based on the results of this study, it is possible to reduce exposure in selected patients, and at the same time obtain sufficient quality of images for clinical purposes.
- 1 January 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 7031269
Open AccessThe Effects of Additional Filtration on Image Quality and Radiation Dose in Cone Beam CT: An In Vivo Preliminary Investigation
Purpose. The aim of this study was to investigate the effect of reduced radiation doses on the image quality of cone‐beam computed tomography scans and the suitability of such imaging for orthodontics, oral surgery, dental implantology, periodontology, and endodontology. Materials and Methods. Cone‐beam computed tomography scans of a live patient were performed using seven attenuation filters with increased thickness to decrease the effective radiation dose from 22.4 to 1.8 μSv, and the effects of different radiation doses on image quality were further analysed. Quantitative image quality was calculated using dedicated measures, such as signal and contrast‐to‐noise ratio and sharpness. A panel of five certified raters assessed the cone‐beam computed tomography scans qualitatively. Nine anatomical structures relevant to dentistry were identified, and the overall acceptance was assessed. Results. Linear reduction of the effective radiation dose had a nonlinear effect on image quality. A 5‐fold reduction in the effective dose led to acceptable quantitative and qualitative image quality measures, and the identification rate of dental anatomical structures was 80% or greater. The use of less than 40% of the reference dose was unacceptable for all dental specialties. Conclusions. The ideal radiation dose for specific diagnostic requirements remains a patient‐related and specialty‐related decision that must be made on an individual basis. Based on the results of this study, it is possible to reduce exposure in selected patients, and at the same time obtain sufficient quality of images for clinical purposes.
- Open Access
- 13 September 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (9) , e0257224
Ultra short time to Echo (UTE) MRI for cephalometric analysis–Potential of an x-ray free fast cephalometric projection technique
Objectives: A novel magnetic resonance imaging (MRI) scan protocol is presented on the basis of ultra-short time to echo (UTE). By this MRI cephalometric projections (MCPs) can be acquired without the need of post processing in one shot. Different technical parameterizations of the protocol are performed. Their impact on the performance of MCPs is evaluated in comparison to the gold standard–the lateral cephalometric radiography (LCR) for cephalometric analysis (CA) in orthodontics. Methods: Seven MCPs with various scan parameters influencing the scan duration and one LCR are used from one subject. 40 expert assessors performed CA for 14 predefined cephalometric landmarks. Relative metric distances and absolute angular measurements were calculated. Statistical analysis is presented and the deviations are highlighted to demonstrate the potential of the method for further analysis. Results: The MCPs are acquired in 5–154 seconds, depending on resolution and contrast. Mean relative distances were 2.4–2.7 mm in MCPs and 1.6 mm in LCR, which demonstrate the accuracy and level of agreement of the expert assessors in identifying anatomical landmarks. In comparison to other studies, the presented MCP performed similar in angular analysis and demonstrated on average deviation of 1.2° ±1.1° in comparison to LCR. Despite the point articulare (Ar) and the related gonial angle the calculate distances and angles show outcomes in the range of ±2°/2mm. Conclusions: MCPs can be acquired much faster in comparison to other techniques known from literature for CA. This study demonstrated the potential of the new method and showed first feasible results. Further research is needed to analyze the performance on a broad range of patients.
- 13 September 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (9) , e0257224
Open AccessUltra short time to Echo (UTE) MRI for cephalometric analysis–Potential of an x-ray free fast cephalometric projection technique
Objectives: A novel magnetic resonance imaging (MRI) scan protocol is presented on the basis of ultra-short time to echo (UTE). By this MRI cephalometric projections (MCPs) can be acquired without the need of post processing in one shot. Different technical parameterizations of the protocol are performed. Their impact on the performance of MCPs is evaluated in comparison to the gold standard–the lateral cephalometric radiography (LCR) for cephalometric analysis (CA) in orthodontics. Methods: Seven MCPs with various scan parameters influencing the scan duration and one LCR are used from one subject. 40 expert assessors performed CA for 14 predefined cephalometric landmarks. Relative metric distances and absolute angular measurements were calculated. Statistical analysis is presented and the deviations are highlighted to demonstrate the potential of the method for further analysis. Results: The MCPs are acquired in 5–154 seconds, depending on resolution and contrast. Mean relative distances were 2.4–2.7 mm in MCPs and 1.6 mm in LCR, which demonstrate the accuracy and level of agreement of the expert assessors in identifying anatomical landmarks. In comparison to other studies, the presented MCP performed similar in angular analysis and demonstrated on average deviation of 1.2° ±1.1° in comparison to LCR. Despite the point articulare (Ar) and the related gonial angle the calculate distances and angles show outcomes in the range of ±2°/2mm. Conclusions: MCPs can be acquired much faster in comparison to other techniques known from literature for CA. This study demonstrated the potential of the new method and showed first feasible results. Further research is needed to analyze the performance on a broad range of patients.