Ahmad Syafiq Aiman A. Bakar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ahmad Syafiq Aiman A. Bakar has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Bo Sun
Centre of Printable Electronics, Research Management and Innovation Complex, Universiti Malaya, Kuala Lumpur, Malaysia
1 shared publication- Fazliyatul Azwa Md Rezali
School of Engineering, Faculty of Innovation & Technology, Taylor’s University, Subang Jaya 47500, Selangor, Malaysia
1 shared publication - Ma Li Ya
Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
1 shared publication - Muhammad Hafizuddin Al-Helmy Nouxman
Centre of Printable Electronics, Research Management and Innovation Complex, Universiti Malaya, Kuala Lumpur, Malaysia
1 shared publication - Norhayati Soin
University of Malaya
1 shared publication - Sharifah Fatmadiana Wan Muhamad Hatta
Universiti Malaya
1 shared publication
Latest Publications
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (6) , 7989-7996
Screen-Printed Organic Electrochemical Transistor With 3-D-Printed Hollow Microneedle for a Fully Integrated Glucose Sensor
In this work, a novel fully integrated glucose sensor based on organic electrochemical transistor (OECT) has been proposed through feasible printing on a flexible substrate. The fully integrated glucose sensor incorporates: 1) a screen-printed OECT featuring poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) channel functionalized with a chitosan–titanium dioxide (CS-TiO₂) nanocomposite and glucose oxidase (GOx) enzyme to enable glucose detection; 2) a 3D-printed 3x3 hollow microneedle (HMN) platform with reservoir pad for minimally invasive sampling; and 3) a flexible compact wireless interfacing circuit for glucose analysis. Mechanical and electrical stability are investigated on the OECT device after 100 bending cycles and over a week of testing on a curved surface. With respect to glucose, the OECT showed a strong linear response in between 0.01 to 30 mM (r² = 0.993), a high sensitivity of 6.01 μA·mM⁻¹·cm⁻², and good selectivity against ascorbic acid and uric acid. Upon integration, the integrated glucose sensor achieved a rapid response time of under 20 s when tested on an agar gel-based skin model. The output currents were calibrated and then verified within the glucose range of 1–10 mM, with a total reading time of less than 120 s, demonstrating good accuracy. Overall, the implementation of OECT coupled with HMN offers a promising platform for a fully integrated glucose sensor, with great potential towards commercialization.
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (6) , 7989-7996
Screen-Printed Organic Electrochemical Transistor With 3-D-Printed Hollow Microneedle for a Fully Integrated Glucose Sensor
In this work, a novel fully integrated glucose sensor based on organic electrochemical transistor (OECT) has been proposed through feasible printing on a flexible substrate. The fully integrated glucose sensor incorporates: 1) a screen-printed OECT featuring poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) channel functionalized with a chitosan–titanium dioxide (CS-TiO₂) nanocomposite and glucose oxidase (GOx) enzyme to enable glucose detection; 2) a 3D-printed 3x3 hollow microneedle (HMN) platform with reservoir pad for minimally invasive sampling; and 3) a flexible compact wireless interfacing circuit for glucose analysis. Mechanical and electrical stability are investigated on the OECT device after 100 bending cycles and over a week of testing on a curved surface. With respect to glucose, the OECT showed a strong linear response in between 0.01 to 30 mM (r² = 0.993), a high sensitivity of 6.01 μA·mM⁻¹·cm⁻², and good selectivity against ascorbic acid and uric acid. Upon integration, the integrated glucose sensor achieved a rapid response time of under 20 s when tested on an agar gel-based skin model. The output currents were calibrated and then verified within the glucose range of 1–10 mM, with a total reading time of less than 120 s, demonstrating good accuracy. Overall, the implementation of OECT coupled with HMN offers a promising platform for a fully integrated glucose sensor, with great potential towards commercialization.