Long-term operational stability and high-efficiency neuron stimulation are key to the development of retinal prostheses. In this research, a retinal device with a chemically inert and flexible substrate is introduced, which satisfies these requirements. We have developed a honeycomb-type retinal device that has a high-performance electrode for suprachoroidal transretinal stimulation. The device structure, in which conjunctional bioceramic substrates are embedded with large numbers of stimulating electrodes, provides high-resolution electrical stimulation. The custom CMOS microchip precisely controls the stimulation delivery of the electrodes to initiate artificial vision, offering a partial remedy for retinal ophthalmic diseases. The CMOS chip design was optimized to drastically reduce the number of input wirings. A high-performance stimulating electrode based on iridium oxide was fabricated using a unique solution process called chemical bath deposition (CBD). The honeycomb-type retinal device, equipped with CBD-derived iridium oxide electrodes, was used to evaluate the electrodes’ and device’s performances in vitro.Keywords
This publication has 31 references indexed in Scilit:
- The Detection of Motion by Blind Subjects With the Epiretinal 60-Electrode (Argus II) Retinal ProsthesisJAMA Ophthalmology, 2013
- Testing of Semichronically Implanted Retinal Prosthesis by Suprachoroidal-Transretinal Stimulation in Patients with Retinitis PigmentosaInvestigative Ophthalmology & Visual Science, 2011
- Development of a micromachined epiretinal vision prosthesisJournal of Neural Engineering, 2009
- Sputtered iridium oxide films for neural stimulation electrodesJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2008
- Neural Stimulation and Recording ElectrodesAnnual Review of Biomedical Engineering, 2008
- Evaluation of phosphenes elicited by extraocular stimulation in normals and by suprachoroidal-transretinal stimulation in patients with retinitis pigmentosaGraefe's Archive for Clinical and Experimental Ophthalmology, 2007
- Visuotopic Mapping Through a Multichannel Stimulating Implant in Primate V1Journal of Neurophysiology, 2005
- Prevalence of Age-Related Macular Degeneration in the United StatesArchives of Ophthalmology (1950), 2004
- Sputtered Iridium Oxide Films as Charge Injection Material for Functional ElectrostimulationJournal of the Electrochemical Society, 2004
- Visual sensations produced by intracortical microstimulation of the human occipital cortexMedical & Biological Engineering & Computing, 1990