Kuang-Chih Tso
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kuang-Chih Tso has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Jun Ohta
Nara Institute of Science and Technology
6 shared publications - Kiyotaka Sasagawa
Division of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Nara, Japan
4 shared publications - Makito Haruta
Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma, Nara, 630-0192, Japan
4 shared publications - Pu-Wei Wu
Department of Materials Science and Engineering, National Yang Ming Chiao Tung University, Hsinchu 300, Taiwan
4 shared publications - Hiroaki Takehara
Division of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Nara, Japan
3 shared publications - Hiroyuki Tashiro
Division of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Nara, Japan
3 shared publications
Latest Publications
- Open Access
- 15 May 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (5) , 580
Development and Evaluation of Multi-Module Retinal Devices for Artificial Vision Applications
Artificial retinal devices require a high-density electrode array and mechanical flexibility to effectively stimulate retinal cells. However, designing such devices presents significant challenges, including the need to conform to the curvature of the eyeball and cover a large area using a single platform. To address these issues, we developed a parylene-based multi-module retinal device (MMRD) integrating a complementary metal-oxide semiconductor (CMOS) system. The proposed device is designed for suprachoroidal transretinal stimulation, with each module comprising a parylene-C thin-film substrate, a CMOS chip, and a ceramic substrate housing seven platinum electrodes. The smart CMOS system significantly reduces wiring complexity, enhancing the device’s practicality. To improve fabrication reliability, we optimized the encapsulation process, introduced multiple silane coupling modifications, and utilized polyvinyl alcohol (PVA) for easier detachment in flip-chip bonding. This study demonstrates the fabrication and evaluation of the MMRD through in vitro and in vivo experiments. The device successfully generated the expected current stimulation waveforms in both settings, highlighting its potential as a promising candidate for future artificial vision applications.
- 15 May 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (5) , 580
Open AccessDevelopment and Evaluation of Multi-Module Retinal Devices for Artificial Vision Applications
Artificial retinal devices require a high-density electrode array and mechanical flexibility to effectively stimulate retinal cells. However, designing such devices presents significant challenges, including the need to conform to the curvature of the eyeball and cover a large area using a single platform. To address these issues, we developed a parylene-based multi-module retinal device (MMRD) integrating a complementary metal-oxide semiconductor (CMOS) system. The proposed device is designed for suprachoroidal transretinal stimulation, with each module comprising a parylene-C thin-film substrate, a CMOS chip, and a ceramic substrate housing seven platinum electrodes. The smart CMOS system significantly reduces wiring complexity, enhancing the device’s practicality. To improve fabrication reliability, we optimized the encapsulation process, introduced multiple silane coupling modifications, and utilized polyvinyl alcohol (PVA) for easier detachment in flip-chip bonding. This study demonstrates the fabrication and evaluation of the MMRD through in vitro and in vivo experiments. The device successfully generated the expected current stimulation waveforms in both settings, highlighting its potential as a promising candidate for future artificial vision applications.
- 1 January 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (1) , 01SP08
Design of CMOS chip for retinal prosthesis with power supply voltage monitoring circuit for stabilizing constant-current stimulation
To advance the practical application of retinal prostheses with high spatial resolution through parallel stimulation, we developed a dynamic power supply voltage control system designed to enable stable constant-current stimulation in vivo, regardless of the number of active stimulation points. The proposed retinal prosthesis integrates a CMOS chip, containing current sources and electrode selection circuits, into a stimulation electrode array implanted in the eye. This configuration facilitates individual control of over 1000 electrodes with minimal wiring. In this study, we designed and integrated a power supply voltage monitoring circuit into the chip, allowing for real-time control of an external power generation circuit through feedback from the intraocular monitoring circuit. We demonstrated that the proposed system rapidly restored the power supply voltage when a voltage drop of 1 V occurred in the Pt wiring between the power supply unit and the chip, even while delivering a stimulation current of 1.5 mA in parallel across more than 100 electrodes.
- 1 January 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (1) , 01SP08
Design of CMOS chip for retinal prosthesis with power supply voltage monitoring circuit for stabilizing constant-current stimulation
To advance the practical application of retinal prostheses with high spatial resolution through parallel stimulation, we developed a dynamic power supply voltage control system designed to enable stable constant-current stimulation in vivo, regardless of the number of active stimulation points. The proposed retinal prosthesis integrates a CMOS chip, containing current sources and electrode selection circuits, into a stimulation electrode array implanted in the eye. This configuration facilitates individual control of over 1000 electrodes with minimal wiring. In this study, we designed and integrated a power supply voltage monitoring circuit into the chip, allowing for real-time control of an external power generation circuit through feedback from the intraocular monitoring circuit. We demonstrated that the proposed system rapidly restored the power supply voltage when a voltage drop of 1 V occurred in the Pt wiring between the power supply unit and the chip, even while delivering a stimulation current of 1.5 mA in parallel across more than 100 electrodes.
- 14 February 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (3) , 03SP22
Demonstration of multi-point stimulation with AC-driven CMOS chips for retinal prosthesis
We demonstrated a multi-point stimulation system using CMOS chips designed for distributed implantable retinal prostheses. The CMOS chip integrates current sources and electrode selection circuits. This integration enables stimulation current control from multiple electrodes with minimal wires. In this study, we constructed a validation system with 49 electrodes capable of visually observing stimulation current outputs. The validation results show that it is possible to configure stimulation conditions in approximately 9.3 μs per electrode, and we demonstrated the ability to complete one frame, including the stimulation time, within approximately 11 ms. We also demonstrated parallel current stimulation from multiple electrodes using an in vitro experiment.
- 14 February 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (3) , 03SP22
Demonstration of multi-point stimulation with AC-driven CMOS chips for retinal prosthesis
We demonstrated a multi-point stimulation system using CMOS chips designed for distributed implantable retinal prostheses. The CMOS chip integrates current sources and electrode selection circuits. This integration enables stimulation current control from multiple electrodes with minimal wires. In this study, we constructed a validation system with 49 electrodes capable of visually observing stimulation current outputs. The validation results show that it is possible to configure stimulation conditions in approximately 9.3 μs per electrode, and we demonstrated the ability to complete one frame, including the stimulation time, within approximately 11 ms. We also demonstrated parallel current stimulation from multiple electrodes using an in vitro experiment.
- 19 December 2023
- Published by Elsevier in Surfaces and Interfaces
- Vol. 44
A robust bendable IrOx thin film via mild alkaline solution process for neuron stimulating electrodes
- 19 December 2023
- Published by Elsevier in Surfaces and Interfaces
- Vol. 44
A robust bendable IrOx thin film via mild alkaline solution process for neuron stimulating electrodes
- 29 November 2023
- Published by Elsevier in Ceramics International
- Vol. 50 (4) , 6220-6228
Reuse of sodium–doped iridium oxide nanoparticles as a bio–stimulating electrode by a chemical and electrochemical recovery process
- 29 November 2023
- Published by Elsevier in Ceramics International
- Vol. 50 (4) , 6220-6228
Reuse of sodium–doped iridium oxide nanoparticles as a bio–stimulating electrode by a chemical and electrochemical recovery process
- 2 October 2023
- Published by Elsevier in Microchemical Journal
- Vol. 195
Metallic Ir-decorated iridium oxide nanofibers with programmable performance towards non-enzymatic detection of hydrogen peroxide
- 2 October 2023
- Published by Elsevier in Microchemical Journal
- Vol. 195
Metallic Ir-decorated iridium oxide nanofibers with programmable performance towards non-enzymatic detection of hydrogen peroxide
- 6 January 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 11 (5) , 1979-1987
Time-resolved XAS studies reveal sequential oxidative–reductive formation of Na-doped iridium oxide films with enhanced bio-stimulating performance
A Na-doped iridium oxide film is heterogeneously deposited on ITO. Time-resolved XAS validates the sequential oxidative–reductive steps for the Ir3+ precursor. The film exhibits an impressive electrochemical performance and a negligible bio-toxicity.
- 6 January 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 11 (5) , 1979-1987
Time-resolved XAS studies reveal sequential oxidative–reductive formation of Na-doped iridium oxide films with enhanced bio-stimulating performance
A Na-doped iridium oxide film is heterogeneously deposited on ITO. Time-resolved XAS validates the sequential oxidative–reductive steps for the Ir3+ precursor. The film exhibits an impressive electrochemical performance and a negligible bio-toxicity.
- Open Access
- 1 September 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (9) , 095305
Honeycomb-type retinal device using chemically derived iridium oxide biointerfaces
Long-term operational stability and high-efficiency neuron stimulation are key to the development of retinal prostheses. In this research, a retinal device with a chemically inert and flexible substrate is introduced, which satisfies these requirements. We have developed a honeycomb-type retinal device that has a high-performance electrode for suprachoroidal transretinal stimulation. The device structure, in which conjunctional bioceramic substrates are embedded with large numbers of stimulating electrodes, provides high-resolution electrical stimulation. The custom CMOS microchip precisely controls the stimulation delivery of the electrodes to initiate artificial vision, offering a partial remedy for retinal ophthalmic diseases. The CMOS chip design was optimized to drastically reduce the number of input wirings. A high-performance stimulating electrode based on iridium oxide was fabricated using a unique solution process called chemical bath deposition (CBD). The honeycomb-type retinal device, equipped with CBD-derived iridium oxide electrodes, was used to evaluate the electrodes’ and device’s performances in vitro.
- 1 September 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (9) , 095305
Open AccessHoneycomb-type retinal device using chemically derived iridium oxide biointerfaces
Long-term operational stability and high-efficiency neuron stimulation are key to the development of retinal prostheses. In this research, a retinal device with a chemically inert and flexible substrate is introduced, which satisfies these requirements. We have developed a honeycomb-type retinal device that has a high-performance electrode for suprachoroidal transretinal stimulation. The device structure, in which conjunctional bioceramic substrates are embedded with large numbers of stimulating electrodes, provides high-resolution electrical stimulation. The custom CMOS microchip precisely controls the stimulation delivery of the electrodes to initiate artificial vision, offering a partial remedy for retinal ophthalmic diseases. The CMOS chip design was optimized to drastically reduce the number of input wirings. A high-performance stimulating electrode based on iridium oxide was fabricated using a unique solution process called chemical bath deposition (CBD). The honeycomb-type retinal device, equipped with CBD-derived iridium oxide electrodes, was used to evaluate the electrodes’ and device’s performances in vitro.