A comparative study of tapped and untapped pilot holes for bicortical orthopedic screws – 3D finite element analysis with an experimental test
- 2 April 2019
- journal article
- research article
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 64 (5) , 563-570
Abstract
The aim of this study was to compare the screw-to-bone fixation strength of two insertion techniques: self-tapping screw (STS) and non-self-tapping screw (NSTS). Finite element analysis (FEA) was used for the comparison by featuring three tests (insertion, pull-out and shear) in a human tibia bone model. A non-linear material behavior with ductile damage properties was chosen for the modeling. To validate the numerical models, experimental insertion and pull-out tests were carried out using a synthetic bone. The experimental and numerical results of pull-out tests correlated well. Thread forming was successfully simulated during the insertion process of STS and NSTS. It is demonstrated that the STS generates higher insertion torque, induces a higher amount of stress after the insertion process and relatively more strength under the pull-out and shear tests than the NSTS. However, the NSTS induces more stiffness under the two tests (pull-out and shear) and less damage to the screw-bone interface compared to the STS. It is concluded that the use of STS ensures tighter bony contact and enables higher pull-out strength; however, the use of NSTS improves the stiffness of the fixation and induces less damage to the cortical bone-screw fixation and thus minimum risk is obtained in terms of bone necrosis.Keywords
This publication has 32 references indexed in Scilit:
- Primary Stability, Insertion Torque, and Bone Density of Conical Implants With Internal HexagonJournal of Craniofacial Surgery, 2013
- Biomechanical properties of an intact, injured, repaired, and healed femur: An experimental and computational studyJournal of the Mechanical Behavior of Biomedical Materials, 2012
- Pullout Performance of Self-Tapping Medical ScrewsJournal of Biomechanical Engineering, 2011
- Pullout Strength and Load to Failure Properties of Self-Tapping Cortical Screws in Synthetic and Cadaveric Environments Representative of Healthy and Osteoporotic BoneJournal of Trauma: Injury, Infection & Critical Care, 2008
- A Comparison of Pullout Strength for Pedicle Screws of Different DesignsSpine, 2006
- Mechanisms governing the inelastic deformation of cortical bone and application to trabecular boneActa Biomaterialia, 2006
- Effects of hole preparation on screw pullout resistance and insertional torque: a biomechanical studyJournal of Neurosurgery: Spine, 2001
- Bone deformation by thread-cutting and thread-forming cortex screwsInjury, 1995
- Optimizing Bone Screw Pullout ForceJournal of Orthopaedic Trauma, 1990
- Comparison of Compression and Torque Measurements of Self-Tapping and Pretapped ScrewsPlastic and Reconstructive Surgery, 1989