Development of Johnson Noise Thermometer Using Quantum Voltage Noise Source
Authors:
- C. UranoCUC. Urano
- Y. OkazakiYOY. Okazaki
- T. YamadaTYT. Yamada
- K. YamazawaKYK. Yamazawa
- Y. FukuyamaYFY. Fukuyama
- N. KanekoNKN. Kaneko
- M. MaruyamaMMM. Maruyama
- A. DomaeADA. Domae
- S. YoshidaSYS. Yoshida
- S. KiryuSKS. Kiryu
- H. YamamoriHYH. Yamamori
- J. TambaJTJ. Tamba
- 1 July 2015
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Abstract
In an effort to refine the value of the Boltzmann constant (k), we made thermodynamic temperature measurements of k using a Johnson noise thermometry (JNT) system, currently under development, using a quantum voltage noise source (QVNS). The JNT system measures the power spectrum density (PSD) of a sensor resistor using the PSD of a QVNS as a reference. k is then obtained using the Johnson-Nyquist equation. k obtained in our measurements to date has an offset of + (3.7±0.1)×10 -5 from the CODATA value.Keywords
This publication has 5 references indexed in Scilit:
- Improved electronic measurement of the Boltzmann constant by Johnson noise thermometryMetrologia, 2015
- Flat Frequency Response in the Electronic Measurement of Boltzmann's ConstantIEEE Transactions on Instrumentation and Measurement, 2013
- An electronic measurement of the Boltzmann constantMetrologia, 2011
- Thermal Agitation of Electricity in ConductorsPhysical Review B, 1928
- Thermal Agitation of Electric Charge in ConductorsPhysical Review B, 1928