A comparison study of radiation exposure to patients during EVAR and Dyna CT in an angiosuite vs. an operating theatre
Authors:
- 10 July 2014
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 163 (4) , 491-498
Abstract
The aim of this study was to assess the patient dosimetric impact of endovascular abdominal aortic aneurysm repair (EVAR), both in an operating theatre (OR) and in an angiosuite (AS), with the facility of Dynamic CT (Dyna CT, Siemens AG, Berlin, Germany). One hundred and forty-six consecutive EVAR procedures dating from May 2011 to March 2013 were analysed. These were performed either in an OR (n = 97) using a mobile C-arm or in an AS (n = 49) equipped with a ceiling-mounted angiography system. Air kerma area product (PKA) and total air kerma at reference point (Ka,r) values were reported for all procedures and Dyna CT. Radiation exposure during EVAR was quite low in the majority of patients but nearly 50 % higher if performed in AS vs. OR. Median Dyna CT Ka,r was the same as an entire EVAR procedure in OR. The higher patient's radiation exposure recorded in the AS should be balanced with the technical advantages given to the EVAR procedure.Keywords
This publication has 26 references indexed in Scilit:
- Practical patient dosimetry for partial rotation cone beam CTBritish Journal of Radiology, 2012
- Risk of deterministic effects during endovascular aortic stent graft implantationBritish Journal of Radiology, 2010
- The impact of radiation dose exposure during endovascular aneurysm repair on patient safetyJournal of Vascular Surgery, 2010
- Effective dose analysis of three-dimensional rotational angiography during catheter ablation proceduresPhysics in Medicine & Biology, 2010
- Three-dimensional cardiac rotational angiography: effective radiation dose and image quality implicationsEP Europace, 2009
- A tandem calibration method for kerma–area product metersPhysics in Medicine & Biology, 2008
- Criteria to optimise a dynamic flat detector system used for interventional radiologyRadiation Protection Dosimetry, 2008
- Evaluation of the quality of CT-like images obtained using a commercial flat panel detector systemBiomedical Imaging and Intervention Journal, 2006
- Are new technologies always reducing patient doses in cardiac procedures?Radiation Protection Dosimetry, 2005
- Radiation exposure in stent-grafting of abdominal aortic aneurysmsBritish Journal of Radiology, 2005