Characterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications
Open Access
- 1 March 2026
- journal article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (03) , P03014
Abstract
High-flux cadmium zinc telluride (HF-CZT) is a promising material for next-generation X-ray imaging due to its high stopping power, wide bandgap, and improved resistance to radiation-induced polarization [1]. We bonded 2 mm thick HF-CZT sensors with Cornell's Mixed-Mode Pixel Array ASICs, which combine analog charge integration and in-pixel digital counting to achieve single X-ray sensitivity, large full well capacity, and frame rates up to 10 kHz [2,3]. Detector characterization showed stable electron collection above 150 V bias, while hole collection remained limited by trapping even at 700 V. Temporal studies revealed non-negligible afterglow, with an unexpected increase in afterglow at higher biases, which was reduced by infrared illumination, suggesting that injected carriers reduce trapping near contact interfaces. Polarization measurements confirmed improved stability compared to conventional CZT, though polarization effects persisted, particularly with hole collection, with up to 5% signal loss and spatial distortion at high doses.Keywords
This publication has 19 references indexed in Scilit:
- High performance platinum contacts on high-flux CdZnTe detectorsScientific Reports, 2023
- Characterization of High-Flux CdZnTe with optimized electrodes for 4th generation synchrotronsJournal of Instrumentation, 2022
- Very-High Dynamic Range, 10,000 Frames/Second Pixel Array Detector for Electron MicroscopyMicroscopy and Microanalysis, 2022
- Characterization of 128 × 128 MM-PAD-2.1 ASIC: a fast framing hard x-ray detector with high dynamic rangeJournal of Instrumentation, 2022
- Characterisation of Redlen high-flux CdZnTeJournal of Instrumentation, 2017
- High Dynamic Range Pixel Array Detector for Scanning Transmission Electron MicroscopyMicroscopy and Microanalysis, 2016
- A Medium-Format, Mixed-Mode Pixel Array Detector for Kilohertz X-ray ImagingJournal of Physics: Conference Series, 2013
- CdTe and Cd1−Zn Te for nuclear detectors: facts and fictionsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999
- CdTe and CdZnTe materials for room-temperature X-ray and gamma ray detectorsJournal of Crystal Growth, 1998
- Crystal growth of large-area single-crystal CdTe and CdZnTe by the computer-controlled vertical modified-Bridgman processJournal of Crystal Growth, 1988