Accelerating implant RF safety assessment using a low‐rank inverse update method
Open Access
- 30 September 2019
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (5) , 1796-1809
Abstract
Purpose: Patients who have medical metallic implants, e.g. orthopaedic implants and pacemakers, often cannot undergo an MRI exam. One of the largest risks is tissue heating due to the radio frequency (RF) fields. The RF safety assessment of implants is computationally demanding. This is due to the large dimensions of the transmit coil compared to the very detailed geometry of an implant.Methods: In this work, we explore a faster computational method for the RF safety assessment of implants that exploits the small geometry. The method requires the RF field without an implant as a basis and calculates the perturbation that the implant induces. The inputs for this method are the incident fields and a library matrix that contains the RF field response of every edge an implant can occupy. Through a low‐rank inverse update, using the Sherman–Woodbury–Morrison matrix identity, the EM response of arbitrary implants can be computed within seconds. We compare the solution from full‐wave simulations with the results from the presented method, for two implant geometries.Results: From the comparison, we found that the resulting electric and magnetic fields are numerically equivalent (maximum error of 1.35%). However, the computation was between 171 to 2478 times faster than the corresponding GPU accelerated full‐wave simulation.Conclusions: The presented method enables for rapid and efficient evaluation of the RF fields near implants and might enable situation‐specific scanning conditions.Keywords
Funding Information
- Netherlands Organisation for Scientific Research
This publication has 21 references indexed in Scilit:
- Evaluation of the RF heating of a generic deep brain stimulator exposed in 1.5 T magnetic resonance scannersBioelectromagnetics, 2012
- Comparison of three multichannel transmit/receive radiofrequency coil configurations for anatomic and functional cardiac MRI at 7.0T: implications for clinical imagingEuropean Radiology, 2012
- Measuring RF‐induced currents inside implants: Impact of device configuration on MRI safety of cardiac pacemaker leadsMagnetic Resonance in Medicine, 2009
- Spatial distribution of RF‐induced E‐fields and implant heating in MRIMagnetic Resonance in Medicine, 2008
- Complexity of MRI induced heating on metallic leads: Experimental measurements of 374 configurationsBioMedical Engineering OnLine, 2008
- Calculation of MRI‐induced heating of an implanted medical lead wire with an electric field transfer functionJournal of Magnetic Resonance Imaging, 2007
- Simple design changes to wires to substantially reduce MRI-induced heating at 1.5 T: implications for implanted leadsMagnetic Resonance Imaging, 2005
- Computational Electromagnetics: The Finite-Difference Time-Domain Method2005
- In vivo heating of pacemaker leads during magnetic resonance imagingEuropean Heart Journal, 2004
- MR Imaging and Cardiac Pacemakers: In Vitro Evaluation and in Vivo Studies in 51 Patients at 0.5 TRadiology, 2000