Janot P. Tokaya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Janot P. Tokaya has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Peter R. Luijten
Department of Radiology University Medical Center Utrecht, P.O. Box 85500, 3508 GA, Utrecht, Netherlands
3 shared publicationsAlexander J. E. Raaijmakers
Department of Radiotherapy, University Medical Center Utrecht, P.O. Box 85500, 3508, GA, Utrecht, Netherlands
2 shared publicationsCornelis A. T. van Den Berg
Department of Radiotherapy, University Medical Center Utrecht, P.O. Box 85500, 3508, GA, Utrecht, Netherlands
2 shared publications- Cássio van Den Berg
Department of Radiotherapy, Computational Imaging Group for MR Therapy and Diagnostics, University Medical Center Utrecht, CX Utrecht, The Netherlands
2 shared publications A.J.E. Raaijmakers
Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
1 shared publicationAlessandro Sbrizzi
Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
1 shared publication
Latest Publications
- Open Access
- 7 May 2020
- Published by Wiley in Medical Physics
- Vol. 48 (1) , 132-141
Explaining RF induced current patterns on implantable medical devices during MRI using the transfer matrix
Purpose In this work a simulation study is performed to gain insights in the patterns of induced radiofrequency (RF) currents for various implant‐like structures at 1.5T. The previously introduced transfer matrix (TM) is used to determine why certain current patterns have a tendency to naturally occur. This can benefit current safety assessment techniques and may enable the identification of critical exposure conditions. Theory and Methods The induced current on an elongated implant can be determined by multiplication of the incident electric field along the implant with its TM. The eigenmode spectrum of the TMs for various lengths and various types of implants are determined. The eigenvector with the highest eigenvalue describes the incident electric field pattern that induces the highest current which in turn will lead to highest heating. Subsequently, a statistical probability analysis is performed using a wide range of potential incident electric field distributions in a representative human subject model during a 1.5T MR exam which are determined by means of electromagnetic FDTD simulations. These incident electric field distributions and the resulting induced current patterns are projected onto eigenvectors of the TM to determine which eigenmodes of the implant dominate the current patterns. Results The eigenvectors of the TM of bare and insulated wires resemble sinusoidal harmonics of a string fixed at both ends similar to the natural‐current distribution on thin antennas(1). The currents on implants shorter than 20cm are generally dominated by the first harmonic (similar to half a sine wave). This is firstly because for these implant lengths (relative to the RF wavelength), the first eigenvalue is more than three times bigger than the second showing the ability of an implant to accommodate one eigenmode better than another. Secondly, the incident electric fields have a high likelihood (≳95,7%) to project predominantly on this first eigenmode. Conclusion The eigenmode spectrum of the TM of an implant provides insight into the expected shape of induced current distributions and worst‐case exposure conditions. For short implants, the first eigenvector is dominant. In addition, realistic incident electric field distributions project more heavily on this eigenvector. Both effects together cause significant currents to always resemble the dominant eigenmode of the TM for short implants at 1.5T.
- 7 May 2020
- Published by Wiley in Medical Physics
- Vol. 48 (1) , 132-141
Open AccessExplaining RF induced current patterns on implantable medical devices during MRI using the transfer matrix
Purpose In this work a simulation study is performed to gain insights in the patterns of induced radiofrequency (RF) currents for various implant‐like structures at 1.5T. The previously introduced transfer matrix (TM) is used to determine why certain current patterns have a tendency to naturally occur. This can benefit current safety assessment techniques and may enable the identification of critical exposure conditions. Theory and Methods The induced current on an elongated implant can be determined by multiplication of the incident electric field along the implant with its TM. The eigenmode spectrum of the TMs for various lengths and various types of implants are determined. The eigenvector with the highest eigenvalue describes the incident electric field pattern that induces the highest current which in turn will lead to highest heating. Subsequently, a statistical probability analysis is performed using a wide range of potential incident electric field distributions in a representative human subject model during a 1.5T MR exam which are determined by means of electromagnetic FDTD simulations. These incident electric field distributions and the resulting induced current patterns are projected onto eigenvectors of the TM to determine which eigenmodes of the implant dominate the current patterns. Results The eigenvectors of the TM of bare and insulated wires resemble sinusoidal harmonics of a string fixed at both ends similar to the natural‐current distribution on thin antennas(1). The currents on implants shorter than 20cm are generally dominated by the first harmonic (similar to half a sine wave). This is firstly because for these implant lengths (relative to the RF wavelength), the first eigenvalue is more than three times bigger than the second showing the ability of an implant to accommodate one eigenmode better than another. Secondly, the incident electric fields have a high likelihood (≳95,7%) to project predominantly on this first eigenmode. Conclusion The eigenmode spectrum of the TM of an implant provides insight into the expected shape of induced current distributions and worst‐case exposure conditions. For short implants, the first eigenvector is dominant. In addition, realistic incident electric field distributions project more heavily on this eigenvector. Both effects together cause significant currents to always resemble the dominant eigenmode of the TM for short implants at 1.5T.
- Open Access
- 21 October 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (3) , 1081-1095
MRI‐based transfer function determination through the transfer matrix by jointly fitting the incident and scattered field
Purpose A purely experimental method for MRI‐based transfer function (TF) determination is presented. A TF characterizes the potential for radiofrequency heating of a linear implant by relating the incident tangential electric field to a scattered electric field at its tip. We utilize the previously introduced transfer matrix (TM) to determine transfer functions solely from the MR measurable quantities, that is, the and transceive phase distributions. This technique can extend the current practice of phantom‐based TF assessment with dedicated experimental setup toward MR‐based methods that have the potential to assess the TF in more realistic situations. Theory and Methods An analytical description of the magnitude and transceive phase distribution around a wire‐like implant was derived based on the TM. In this model, the background field is described using a superposition of spherical and cylindrical harmonics while the transfer matrix is parameterized using a previously introduced attenuated wave model. This analytical description can be used to estimate the transfer matrix and transfer function based on the measured distribution. Results The TF was successfully determined for 2 mock‐up implants: a 20‐cm bare copper wire and a 20‐cm insulated copper wire with 10 mm of insulation stripped at both endings in respectively 4 and 3 different trajectories. The measured TFs show a strong correlation with a reference determined from simulations and between the separate experiments with correlation coefficients above 0.96 between all TFs. Compared to the simulated TF, the maximum deviation in the estimated tip field is 9.4% and 12.2% for the bare and insulated wire, respectively. Conclusions A method has been developed to measure the TF of medical implants using MRI experiments. Jointly fitting the incident and scattered distributions with an analytical description based on the transfer matrix enables accurate determination of the TF of 2 test implants. The presented method no longer needs input from simulated data and can therefore, in principle, be used to measure TF's in test animals or corpses.
- 21 October 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (3) , 1081-1095
Open AccessMRI‐based transfer function determination through the transfer matrix by jointly fitting the incident and scattered field
Purpose A purely experimental method for MRI‐based transfer function (TF) determination is presented. A TF characterizes the potential for radiofrequency heating of a linear implant by relating the incident tangential electric field to a scattered electric field at its tip. We utilize the previously introduced transfer matrix (TM) to determine transfer functions solely from the MR measurable quantities, that is, the and transceive phase distributions. This technique can extend the current practice of phantom‐based TF assessment with dedicated experimental setup toward MR‐based methods that have the potential to assess the TF in more realistic situations. Theory and Methods An analytical description of the magnitude and transceive phase distribution around a wire‐like implant was derived based on the TM. In this model, the background field is described using a superposition of spherical and cylindrical harmonics while the transfer matrix is parameterized using a previously introduced attenuated wave model. This analytical description can be used to estimate the transfer matrix and transfer function based on the measured distribution. Results The TF was successfully determined for 2 mock‐up implants: a 20‐cm bare copper wire and a 20‐cm insulated copper wire with 10 mm of insulation stripped at both endings in respectively 4 and 3 different trajectories. The measured TFs show a strong correlation with a reference determined from simulations and between the separate experiments with correlation coefficients above 0.96 between all TFs. Compared to the simulated TF, the maximum deviation in the estimated tip field is 9.4% and 12.2% for the bare and insulated wire, respectively. Conclusions A method has been developed to measure the TF of medical implants using MRI experiments. Jointly fitting the incident and scattered distributions with an analytical description based on the transfer matrix enables accurate determination of the TF of 2 test implants. The presented method no longer needs input from simulated data and can therefore, in principle, be used to measure TF's in test animals or corpses.
- Open Access
- 30 September 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (5) , 1796-1809
Accelerating implant RF safety assessment using a low‐rank inverse update method
Purpose: Patients who have medical metallic implants, e.g. orthopaedic implants and pacemakers, often cannot undergo an MRI exam. One of the largest risks is tissue heating due to the radio frequency (RF) fields. The RF safety assessment of implants is computationally demanding. This is due to the large dimensions of the transmit coil compared to the very detailed geometry of an implant.Methods: In this work, we explore a faster computational method for the RF safety assessment of implants that exploits the small geometry. The method requires the RF field without an implant as a basis and calculates the perturbation that the implant induces. The inputs for this method are the incident fields and a library matrix that contains the RF field response of every edge an implant can occupy. Through a low‐rank inverse update, using the Sherman–Woodbury–Morrison matrix identity, the EM response of arbitrary implants can be computed within seconds. We compare the solution from full‐wave simulations with the results from the presented method, for two implant geometries.Results: From the comparison, we found that the resulting electric and magnetic fields are numerically equivalent (maximum error of 1.35%). However, the computation was between 171 to 2478 times faster than the corresponding GPU accelerated full‐wave simulation.Conclusions: The presented method enables for rapid and efficient evaluation of the RF fields near implants and might enable situation‐specific scanning conditions.
- 30 September 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (5) , 1796-1809
Open AccessAccelerating implant RF safety assessment using a low‐rank inverse update method
Purpose: Patients who have medical metallic implants, e.g. orthopaedic implants and pacemakers, often cannot undergo an MRI exam. One of the largest risks is tissue heating due to the radio frequency (RF) fields. The RF safety assessment of implants is computationally demanding. This is due to the large dimensions of the transmit coil compared to the very detailed geometry of an implant.Methods: In this work, we explore a faster computational method for the RF safety assessment of implants that exploits the small geometry. The method requires the RF field without an implant as a basis and calculates the perturbation that the implant induces. The inputs for this method are the incident fields and a library matrix that contains the RF field response of every edge an implant can occupy. Through a low‐rank inverse update, using the Sherman–Woodbury–Morrison matrix identity, the EM response of arbitrary implants can be computed within seconds. We compare the solution from full‐wave simulations with the results from the presented method, for two implant geometries.Results: From the comparison, we found that the resulting electric and magnetic fields are numerically equivalent (maximum error of 1.35%). However, the computation was between 171 to 2478 times faster than the corresponding GPU accelerated full‐wave simulation.Conclusions: The presented method enables for rapid and efficient evaluation of the RF fields near implants and might enable situation‐specific scanning conditions.
- Open Access
- 24 April 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (6) , 2771-2784
MRI‐based, wireless determination of the transfer function of a linear implant: Introduction of the transfer matrix
Purpose We introduce the transfer matrix (TM) that makes MR‐based wireless determination of transfer functions (TFs) possible. TFs are implant specific measures for RF‐safety assessment of linear implants. The TF relates an incident tangential electric field on an implant to a scattered electric field at its tip that generally governs local heating. The TM extends this concept and relates an incident tangential electric field to a current distribution in the implant therewith characterizing the RF response along the entire implant. The TM is exploited to measure TFs with MRI without hardware alterations. Theory and Methods A model of rightward and leftward propagating attenuated waves undergoing multiple reflections is used to derive an analytical expression for the TM. This allows parameterization of the TM of generic implants, e.g., (partially) insulated single wires, in a homogeneous medium in a few unknowns that simultaneously describe the TF. These unknowns can be determined with MRI making it possible to measure the TM and, therefore, also the TF. Results The TM is able to predict an induced current due to an incident electric field and can be accurately parameterized with a limited number of unknowns. Using this description the TF is determined accurately (with a Pearson correlation coefficient R ≥ 0.9 between measurements and simulations) from MRI acquisitions. Conclusion The TM enables measuring of TFs with MRI of the tested generic implant models. The MR‐based method does not need hardware alterations and is wireless hence making TF determination in more realistic scenarios conceivable.
- 24 April 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (6) , 2771-2784
Open AccessMRI‐based, wireless determination of the transfer function of a linear implant: Introduction of the transfer matrix
Purpose We introduce the transfer matrix (TM) that makes MR‐based wireless determination of transfer functions (TFs) possible. TFs are implant specific measures for RF‐safety assessment of linear implants. The TF relates an incident tangential electric field on an implant to a scattered electric field at its tip that generally governs local heating. The TM extends this concept and relates an incident tangential electric field to a current distribution in the implant therewith characterizing the RF response along the entire implant. The TM is exploited to measure TFs with MRI without hardware alterations. Theory and Methods A model of rightward and leftward propagating attenuated waves undergoing multiple reflections is used to derive an analytical expression for the TM. This allows parameterization of the TM of generic implants, e.g., (partially) insulated single wires, in a homogeneous medium in a few unknowns that simultaneously describe the TF. These unknowns can be determined with MRI making it possible to measure the TM and, therefore, also the TF. Results The TM is able to predict an induced current due to an incident electric field and can be accurately parameterized with a limited number of unknowns. Using this description the TF is determined accurately (with a Pearson correlation coefficient R ≥ 0.9 between measurements and simulations) from MRI acquisitions. Conclusion The TM enables measuring of TFs with MRI of the tested generic implant models. The MR‐based method does not need hardware alterations and is wireless hence making TF determination in more realistic scenarios conceivable.
- 5 February 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 78 (6) , 2449-2459
MRI‐based transfer function determination for the assessment of implant safety
Purpose: We introduce a new MR‐based method to determine the transfer function (TF) for radiofrequency (RF) safety assessment of active implantable medical devices. Transfer functions are implant‐specific measures that relate the incident tangential electric field on an (elongated) implant to a scattered electric field at its tip. The proposed method allows for TF determination with a high spatial resolution in relatively fast measurements without requiring dedicated bench setups from MRI images.Theory and Methods: The principle of reciprocity is used in conjunction with the potential to measure currents with MRI to determine TF. Low‐flip angle 3D dual gradient echo MRI data are acquired with an implant as transceive antenna, which requires minimal hardware adaptations. The implant‐specific TF is determined from the acquired MRI data, with two different postprocessing methods for comparison.Results: TFs of linear and helical implants can be determined accurately (with a Pearson correlation coefficient R ≥ 0.7 between measurements and simulations, and a difference in field at the tip ΔEtip ≤ 19%) from relatively quick (t < 20 minutes) MRI acquisitions with (several) millimeter spatial resolution.Conclusion: Transfer function determination with MRI for RF safety assessment of implantable medical devices is possible. The proposed MR‐based method allows for TF determination in more realistic exposure scenarios and solid media. Magn Reson Med 78:2449–2459, 2017. © 2017 International Society for Magnetic Resonance in Medicine
- 5 February 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 78 (6) , 2449-2459
MRI‐based transfer function determination for the assessment of implant safety
Purpose: We introduce a new MR‐based method to determine the transfer function (TF) for radiofrequency (RF) safety assessment of active implantable medical devices. Transfer functions are implant‐specific measures that relate the incident tangential electric field on an (elongated) implant to a scattered electric field at its tip. The proposed method allows for TF determination with a high spatial resolution in relatively fast measurements without requiring dedicated bench setups from MRI images.Theory and Methods: The principle of reciprocity is used in conjunction with the potential to measure currents with MRI to determine TF. Low‐flip angle 3D dual gradient echo MRI data are acquired with an implant as transceive antenna, which requires minimal hardware adaptations. The implant‐specific TF is determined from the acquired MRI data, with two different postprocessing methods for comparison.Results: TFs of linear and helical implants can be determined accurately (with a Pearson correlation coefficient R ≥ 0.7 between measurements and simulations, and a difference in field at the tip ΔEtip ≤ 19%) from relatively quick (t < 20 minutes) MRI acquisitions with (several) millimeter spatial resolution.Conclusion: Transfer function determination with MRI for RF safety assessment of implantable medical devices is possible. The proposed MR‐based method allows for TF determination in more realistic exposure scenarios and solid media. Magn Reson Med 78:2449–2459, 2017. © 2017 International Society for Magnetic Resonance in Medicine