Effective dose to patient measurements in flat-detector and multislice computed tomography: a comparison of applications in neuroradiology
- 2 April 2014
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 24 (6) , 1257-1265
Abstract
Flat-detector CT (FD-CT) is used for a variety of applications. Additionally, 3D rotational angiography (3D DSA) is used to supplement digital subtraction angiography (DSA) studies. The aim was to measure and compare the dose of (1) standard DSA and 3D DSA and (2) analogous FD-CT and multislice CT (MSCT) protocols. Using an anthropomorphic phantom, the effective dose to patients (according to ICRP 103) was measured on an MSCT and a flat-detector angiographic system using standard protocols as recommended by the manufacturer. (1) Evaluation of DSA and 3D DSA angiography protocols: ap.-lat. Standard/low-dose series 1/0.8 mSv, enlarged oblique projection 0.3 mSv, 3D DSA 0.9 mSv (limited coverage length 0.3 mSv). (2) Comparison of FD-CT and MSCT: brain parenchyma imaging 2.9 /1.4 mSv, perfusion imaging 2.3/4.2 mSv, temporal bone 0.2 /0.2 mSv, angiography 2.9/3.3 mSv, limited to the head using collimation 0.5/0.5 mSv. The effective dose for an FD-CT application depends on the application used. Using collimation for FD-CT applications, the dose may be reduced considerably. Due to the low dose of 3D DSA, we recommend using this technique to reduce the number of DSA series needed to identify working projections. • Effective dose of FD-CT in comparison to MSCT is in comparable range. • Collimation decreases the dose of FD-CT effectively. • Effective dose of 3-D angiography is identical to 2-D DSA. • Different FD-CT programs have different dose.Keywords
This publication has 24 references indexed in Scilit:
- Relationships of clinical protocols and reconstruction kernels with image quality and radiation dose in a 128-slice CT scanner: Study with an anthropomorphic and water phantomEuropean Journal of Radiology, 2012
- Effective dose to patient during neuroradiological procedures of c-arm CTDiagnostic and Interventional Radiology, 2012
- Radiation dose from 3D rotational X-ray imaging: organ and effective dose with conversion factorsRadiation Protection Dosimetry, 2011
- Flat Detector CT in the Evaluation of Brain Parenchyma, Intracranial Vasculature, and Cerebral Blood Volume: A Pilot Study in Patients with Acute Symptoms of Cerebral IschemiaAmerican Journal of Neuroradiology, 2010
- Dose Exposure of Patients Undergoing Comprehensive Stroke Imaging by Multidetector-Row CT: Comparison of 320-Detector Row and 64-Detector Row CT ScannersAmerican Journal of Neuroradiology, 2010
- Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prosthesesEuropean Radiology, 2009
- Computed tomography dose assessment for a 160 mm wide, 320 detector row, cone beam CT scannerPhysics in Medicine & Biology, 2009
- Neuroradiologic Applications with Routine C-arm Flat Panel Detector CT: Evaluation of Patient Dose MeasurementsAmerican Journal of Neuroradiology, 2008
- Angiographic CT with intravenous administration of contrast medium is a noninvasive option for follow-up after intracranial stentingNeuroradiology, 2008
- Flat-Panel Volume Computed Tomography for Cochlear Implant Electrode Array Examination in Isolated Temporal Bone SpecimensOtology & Neurotology, 2006