Yanghui Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yanghui Wang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Huiyun Wang
Zhejiang Institute of Photoelectronics 2 , Jinhua 321004
2 shared publications - Liang He
National Synchrotron Radiation Laboratory, University of Science and Technology of China 1 , Hefei 230029
2 shared publications - Shuai Zhao
University of Science and Technology of China
2 shared publications - Xuewei Du
University of Science and Technology of China
2 shared publications - Qiuping Wang
National Synchrotron Radiation Laboratory, University of Science and Technology of China , Hefei 230029
1 shared publication - Shuo Fu
National Synchrotron Radiation Laboratory, University of Science and Technology of China 1 , Hefei 230029
1 shared publication
Latest Publications
- 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
LTP-corrected stitching interferometer achieving sub-nanometer accuracy for x-ray mirror metrology
This paper presents a sub-nanometer accuracy stitching interferometry system for metrology of large curved x-ray mirrors, incorporating Long Trace Profiler (LTP) low-frequency correction. Utilizing a Fizeau interferometer with a reference transmission flat to measure sub-apertures of flat or curved optics, the system employs a mixed stitching method to achieve high-precision metrology of large x-ray mirrors. Crucially, the instrument overcomes cumulative angular errors in sub-aperture stitching through LTP-guided correction, achieving 0.18 nm RMS measurement repeatability validated on high-precision optics. After calibration of the transmission reference flat and zoom factor, the system demonstrates exceptional consistency with direct LTP measurements (<0.2 nm RMS), surpassing software-only techniques, while successfully verifying curved-mirror capability via <1% radius error measurement on spherical mirror with a radius of curvature of 24.6 m. For challenging elliptical synchrotron x-ray mirrors, our measurements of a specimen with 50 nrad RMS slope error and 0.5 nm RMS height error demonstrate excellent agreement with both manufacturer’s RADSI and LTP reference data. By eliminating angular drift propagation during the stitching process, this metrology system achieves sub-nanometer measurement accuracy for strongly curved x-ray optics.
- 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
LTP-corrected stitching interferometer achieving sub-nanometer accuracy for x-ray mirror metrology
This paper presents a sub-nanometer accuracy stitching interferometry system for metrology of large curved x-ray mirrors, incorporating Long Trace Profiler (LTP) low-frequency correction. Utilizing a Fizeau interferometer with a reference transmission flat to measure sub-apertures of flat or curved optics, the system employs a mixed stitching method to achieve high-precision metrology of large x-ray mirrors. Crucially, the instrument overcomes cumulative angular errors in sub-aperture stitching through LTP-guided correction, achieving 0.18 nm RMS measurement repeatability validated on high-precision optics. After calibration of the transmission reference flat and zoom factor, the system demonstrates exceptional consistency with direct LTP measurements (<0.2 nm RMS), surpassing software-only techniques, while successfully verifying curved-mirror capability via <1% radius error measurement on spherical mirror with a radius of curvature of 24.6 m. For challenging elliptical synchrotron x-ray mirrors, our measurements of a specimen with 50 nrad RMS slope error and 0.5 nm RMS height error demonstrate excellent agreement with both manufacturer’s RADSI and LTP reference data. By eliminating angular drift propagation during the stitching process, this metrology system achieves sub-nanometer measurement accuracy for strongly curved x-ray optics.
- Open Access
Stitching Interferometry for X-Ray Mirror Metrology at the Hefei Advanced Light Facility (HALF)
The advancements in the 4th-generation synchrotron radiation light sources, characterized by their enhanced coherence and brightness, have led to more stringent requirements for the surface quality of X-ray mirrors used in beamlines. This poses a significant challenge to the metrology of X-ray mirrors. This research work focuses on high-precision measurement techniques for X-ray mirrors. The algorithmic principles of various stitching methods were introduced in detail, and a custom-built stitching measurement system was demonstrated. The system was used to perform a stitching measurement on an elliptical X-ray mirror, and the results showed high consistency with the data provided by JTEC. This verifies the effectiveness of the stitching interferometry method and the high measurement capability of our system.
Open AccessStitching Interferometry for X-Ray Mirror Metrology at the Hefei Advanced Light Facility (HALF)
The advancements in the 4th-generation synchrotron radiation light sources, characterized by their enhanced coherence and brightness, have led to more stringent requirements for the surface quality of X-ray mirrors used in beamlines. This poses a significant challenge to the metrology of X-ray mirrors. This research work focuses on high-precision measurement techniques for X-ray mirrors. The algorithmic principles of various stitching methods were introduced in detail, and a custom-built stitching measurement system was demonstrated. The system was used to perform a stitching measurement on an elliptical X-ray mirror, and the results showed high consistency with the data provided by JTEC. This verifies the effectiveness of the stitching interferometry method and the high measurement capability of our system.