Comparison of a micro-electro-mechanical system airflow sensor with the pneumotach in the forced oscillation technique
Open Access
- 1 December 2018
- journal article
- research article
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. ume 11, 419-426
Abstract
Purpose: This study supports the use of thin-film micro-electro-mechanical system (MEMS) airflow sensors in the forced oscillation technique. Materials and methods: The study employed static testing using air flow standards and computer-controlled sound attenuations at 8 Hz. Human feasibility studies were conducted with a testing apparatus consisting of a pneumotach and thin-film MEMS air flow sensors in series. Short-time Fourier transform spectra were obtained using SIGVIEW software. Results: Three tests were performed, and excellent correlations were observed between the probes. The thin-film MEMS probe showed superior sensitivity to higher frequencies up to 200 Hz. Conclusion: The results suggest that lower-cost thin-film MEMS can be used for forced oscillation technique applications (including home care devices) that will benefit patients suffering from pulmonary diseases such as asthma, COPD, and cystic fibrosis.Keywords
This publication has 30 references indexed in Scilit:
- A Study of Artifacts and Their Removal During Forced Oscillation of the Respiratory SystemAnnals of Biomedical Engineering, 2013
- Modeling stochastic and spatial heterogeneity in a human airway tree to determine variation in respiratory system resistanceJournal of Applied Physiology, 2012
- Detection of expiratory flow limitation in COPD using the forced oscillation techniqueEuropean Respiratory Journal, 2004
- Measurement of lung volume and ventilation distribution with an ultrasonic flow meter in healthy infantsEuropean Respiratory Journal, 2002
- Airway Constriction Pattern Is a Central Component of Asthma SeverityAmerican Journal of Respiratory and Critical Care Medicine, 2001
- Forced oscillation assessment of respiratory mechanics in ventilated patientsCritical Care, 2001
- High-frequency Respiratory Impedance Measured by Forced-Oscillation Technique in InfantsAmerican Journal of Respiratory and Critical Care Medicine, 1998
- Respiratory health screening using pulmonary function tests and lung sound analysisEuropean Respiratory Journal, 1994
- Real-time tracking of parameters of lung mechanics: emphasis on algorithm tuningJournal of Biomedical Engineering, 1990
- Dynamic Approach to AsthmaJournal of Asthma, 1983