Bird Droppings Flashover Protection Range for 330 kV I-string Composite Insulators Considering Shielding Ring
- 16 October 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (1) , 69-78
Abstract
When the radius of protection against bird droppings is determined for 330 kV insulators in line with the standard GB/T 35695-2017, the influence of the shielding ring is ignored. Also, bird droppings can’t be prevented from flashing accidents by the protection range with a radius of 0.85 m from the center of the insulator axis. Therefore, it is proposed in this paper to determine the bird droppings protection range (BDPR) by introducing a rotational scanning method along the shielding ring boundary. It is discovered that the average breakdown electric field strength (BEFS) of the residual air gap (RAG) is 3.38 kV/cm when the cotton cord rope end is above the cylindrical tube of the shielding ring, 3.0 kV/cm when the rope end is positioned on the outside of the cylindrical tube, and 2.7 kV/cm when the rope end is located on the outer-side of the curved tube of the shielding ring. The other three shielding rings are used to verify the universality of the proposed method in determining the range of protection against bird droppings flashover.Keywords
This publication has 12 references indexed in Scilit:
- Electric field simulation analysis of ICOG corona ring and study on flashover characteristics of bird droppingsElectric Power Systems Research, 2024
- Analysis and Protection Studies of Bird Droppings on the Electric Field Distribution Near 330 kV Transmission Line Cathead Towers With Composite InsulatorsIEEE Access, 2023
- Insulation Reinforcement for Cable Connector of CRH2 Electric Multiple Unit Under Standard Lightning Impulse VoltageIEEE Transactions on Transportation Electrification, 2022
- Experimental Study On Bird Streamer Flashover for V-Type Insulators of DC Transmission Line in High Altitude AreaIEEE Transactions on Power Delivery, 2022
- High-risk region of bird streamer flashover in 110 kV composite insulators and design for bird-preventing shieldInternational Journal of Electrical Power & Energy Systems, 2021
- Research on the Protection Range of Bird Droppings of 110kV Transmission Line Based on ANSYS MaxwellJournal of Physics: Conference Series, 2019
- Preventing Bird Streamer Outages Using Alternative Tower ConfigurationsIEEE Transactions on Power Delivery, 2014
- High-risk region of bird streamer flashover in high-voltage transmission linesJournal of Electrostatics, 2009
- Bird streamer caused flashover in EHV transmission lineIEEE Transactions on Dielectrics and Electrical Insulation, 2009
- Preventive Measures to Reduce Bird Related Power Outages—Part II: Streamers and ContaminationIEEE Transactions on Power Delivery, 2004