    Electrothermal Failure Mechanism of Multi-Finger Contacts in a Disconnector Under Foundation-Induced Displacement

    by Jia Zhang, Bodong Chen, Kang Liu, Tiancun Wu, Hailong Wang, Luyao Wang, Miao Wen

    To clarify the electrothermal failure of fixed contacts in a 363 kV three-phase five-column disconnector, field inspection, circuit-resistance tests, contact-mechanical modeling, finger-level resistance calculation, and electrothermal simulation were combined. The fault side had approximately 10 mm settlement and 51 mm horizontal displacement. Unserved contacts remained at 81–83 μΩ, whereas field-served contacts showed displacement-sensitive, non-monotonic resistance changes. A finite element model of 24 contact fingers with assembly-induced prestress was developed. Contact pressures were calculated under normal, settlement, and combined settlement—horizontal displacement conditions. Normal force was integrated over each contact area, and zero pressure denoted contact loss. The force, contact length, and equivalent contact width were used in a cylinder-on-flat model to calculate finger resistance. These resistances were connected in parallel and calibrated against the measured normal-state resistance of 83.57 μΩ. Settlement redistributed load from lower to upper fingers, while further horizontal displacement concentrated contact on one side; eastward displacement caused all bottom-row fingers to lose contact. Electrothermal simulation showed little temperature change while most fingers remained in contact, but temperatures exceeded 130 °C after bottom-row contact loss. Thus, total resistance can conceal local degradation, while load redistribution and current concentration increase Joule heating in remaining paths and explain burnout.

  • Open Access

    Collaborative Suppression Method Based on Current Preprocessing and Active Power Decoupling for Second-Order DC Voltage Ripple in PFC Converters

    by Wei Chen, Hang Zhang, Jia Zhang, Feng Wang, Dingjun Wen, Feixing Wang, Kang Liu, Yongliang Yao, Dibin Zhu, Yong Wang, et al.

    This paper presents a collaborative second-order voltage ripple suppression control method for single-phase power factor correction (PFC) converters. First, the causes of second-order DC output voltage ripples are analyzed. Then a modified current preprocessing mechanism is presented for the PFC in order to elevate valley power and suppress peak power, which is able to reduce the second-order power fluctuations. Parameter design and constraints are further provided to obtain a reasonable trade-off between current distortion and the suppressing effect. Meanwhile, an active power decoupling (APD) circuit reusing a capacitor half-bridge is also embedded into the PFC converter. For the APD circuit, this paper calculates and determines the capacitor voltage reference for the purpose of absorbing second-order power fluctuations. Moreover, a closed-loop control strategy for APD is presented to achieve tracking of the capacitor voltage. A coordinate control algorithm is introduced to monitor the cooperative relationship between PFC and APD control. Finally, a 400 W PFC prototype is constructed, and experimental tests are then carried out for verification. The results obtained based on the prototype can confirm the feasibility of the control strategy and the correctness of the theoretical analysis discussed in this paper.

  • Open Access

    Transient Stability Enhancement and Voltage Support for Grid-Forming Converters via Adaptive Improved Observer Control Under Grid Fault

    by Wei Chen, Hang Zhang, Jia Zhang, Feng Wang, Dingjun Wen, Feixing Wang, Kang Liu, Yuanzhen Xu, Zhenzhen Xie, Wei Lv, et al.

    With the large-scale integration of renewable energy sources, grid-forming (GFM) converters with inherent voltage and frequency support capabilities have attracted significant attention. However, due to the limited overcurrent withstand capability of power electronic devices, the stable operation of GFM converters under grid faults such as grid voltage sags remains a critical challenge. To address this issue, this paper systematically investigates the mechanisms of power angle instability and overcurrent generation during grid faults by a unified equivalent impedance model. Based on this analysis, a comprehensive control strategy that simultaneously considers power angle stability and overcurrent suppression is proposed. By introducing an adaptive improved observer control (AIOC), the active power reference is adaptively adjusted to enhance the power angle stability of the system. Meanwhile, the voltage reference is dynamically regulated to effectively limit the fault current while enhancing the voltage support capability. Finally, comprehensive theoretical analysis and experimental validation are provided. The experimental results demonstrate that the proposed strategy is capable of ensuring power angle stability and limits the overcurrent to within 1.5 p.u. Meanwhile, the voltage magnitude is increased by approximately 6%. The results demonstrate the robustness and adaptability of the proposed method under various conditions.

  • Bird Droppings Flashover Protection Range for 330 kV I-string Composite Insulators Considering Shielding Ring

    by Kang Liu, Yudi Fan, Zhenxiang Ma, Jianqiao Ma, Mingxing Tian, Yihu Wang, Shuyao Zhang

    When the radius of protection against bird droppings is determined for 330 kV insulators in line with the standard GB/T 35695-2017, the influence of the shielding ring is ignored. Also, bird droppings can’t be prevented from flashing accidents by the protection range with a radius of 0.85 m from the center of the insulator axis. Therefore, it is proposed in this paper to determine the bird droppings protection range (BDPR) by introducing a rotational scanning method along the shielding ring boundary. It is discovered that the average breakdown electric field strength (BEFS) of the residual air gap (RAG) is 3.38 kV/cm when the cotton cord rope end is above the cylindrical tube of the shielding ring, 3.0 kV/cm when the rope end is positioned on the outside of the cylindrical tube, and 2.7 kV/cm when the rope end is located on the outer-side of the curved tube of the shielding ring. The other three shielding rings are used to verify the universality of the proposed method in determining the range of protection against bird droppings flashover.


  • Open Access

    Analysis and Protection Studies of Bird Droppings Falling on the Electric Field Distribution Near the 330-kV Transmission Line V-Type Composite Insulators

    by Wenzhuo Wang, Zhenxiang Ma, Yudi Fan, Jianqiao Ma, Kang Liu, Yihu Wang, Hao Xu

    Recently, the number of birds along the 330kV transmission lines in the northwest region has gradually increased. The frequency of birds nesting and excreting on the towers has been steadily rising, with bird droppings increasingly becoming the primary factor causing bird-related tripping faults. A three-dimensional model of the tower cross arm, continuous bird droppings, and insulators was constructed to simulate and analyze the impact characteristics of bird droplet diameter, length, and relative position to insulators on the spatial electric field near the insulators. Experimental corrections were made, and based on simulation and experimental results, a bird-proof baffle was designed. Research results indicate that under conditions of single-ended grounding and suspended droplets of bird droppings, the average electric field strength at the lower end of the bird droppings and the grading ring was extracted to define the protective area against irregular-shaped bird droppings. After experimental validation, a correction coefficient of 1.4 was obtained based on the experimental results. A square protective baffle with a diversion function was designed based on simulation and experimental results. Bird droppings were placed at the baffle’s diversion groove, and the average electric field strength between the lower end of the bird droppings and the grading ring was consistently lower than the breakdown field strength of 2.98 kV/cm. The research results of this paper can serve as a basis for the subsequent designing of physical models of bird-proof baffles and prevention of bird-related flashover faults on V-type insulators.


  • Open Access

    Analysis and Protection Studies of Bird Droppings on the Electric Field Distribution Near 330 kV Transmission Line Cathead Towers With Composite Insulators

    by Kang Liu, Yudi Fan, Jianqiao Ma, Yihu Wang, Hao Xu

    The increase in bird populations along the Hexi Corridor has led to an increase in flashover faults on 330 kV transmission lines caused by bird droppings. To mitigate the issue of line tripping caused by bird droppings, it is necessary to analyze the distribution of the electric field near composite insulators during the process of bird droppings falling. A three-dimensional model, including the tower, bird droppings, and insulators, was created to assess the impact of bird droppings’ characteristics on the electric field near the insulators. Based on simulation results, a bird-proof cover was designed to modify the trajectory of the bird droppings’ path. The research found that when bird droppings are grounded and continuous, the most severe distortion of the residual air gap field occurs at a distance of 599.34 mm from the insulator axis. In the dynamic process of ungrounded and continuous bird droppings falling downward with a length less than 3200 mm, the electric field intensity in the residual air gap remains below 5.66 kV/cm outside the circular area centered at the insulator skirt with a radius of 740 mm. Based on the simulation results under both single-end grounded and ungrounded conditions of bird droppings, a bird-proof cover structure was devised to alter the location where bird droppings fall. After bird droppings fall along the edges of the bird-proof cover, the average electric field intensity between the bird droppings and the high-voltage terminal is maintained below 3.02 kV/cm. These research findings lay the foundation for subsequent fabrication of physical models of bird-proof covers.


  • Open Access

    Realization of Harmonic Impedance Simulation Calculation Method for Grounding Grid in Substation

    by Kang Liu, Dingjun Wen, Guangdong Zhang, Chunjiang Hu, Ying Chen

    There is a difference between the actual impedance of substations' ground grid under harmonic interference and that measured under power frequency. Especially under strong harmonic interference, the difference becomes more obvious between the actual one and that measured under power frequency. A method is proposed in this paper to calculate parameters of ground grid models by measuring the ground grid impedances under power frequency and then calculate those under harmonic interference. This method is capable of solving the problem that it is impossible to measure the actual grounding impedance of substations operating under harmonic waves. The feasibility of the method is verified by means of simulating calculations. After correcting by this method, the grounding impedance modulus error becomes less than 2% and the impedance angle error less than 10%. This method may be applied to the measurement and analysis of grounding impedances of substations under harmonic interference.