Kang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kang Liu has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Jia Zhang
State Grid Gansu Electric Power Research Institute, Lanzhou 730070, China
3 shared publications - Jianqiao Ma
Department of Electrical Engineering, School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, China
3 shared publications - Yihu Wang
State Grid Gansu Electric Power Research Institute, Lanzhou, China
3 shared publications - Yudi Fan
Department of Power Engineering, School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, China
3 shared publications - Dibin Zhu
Shanghai Jiao Tong University
2 shared publications - Feng Wang
Electric Power Research Institute, State Grid Gansu Electric Power Company, Lanzhou 730050, China
2 shared publications
Latest Publications
- Open Access
Electrothermal Failure Mechanism of Multi-Finger Contacts in a Disconnector Under Foundation-Induced Displacement
To clarify the electrothermal failure of fixed contacts in a 363 kV three-phase five-column disconnector, field inspection, circuit-resistance tests, contact-mechanical modeling, finger-level resistance calculation, and electrothermal simulation were combined. The fault side had approximately 10 mm settlement and 51 mm horizontal displacement. Unserved contacts remained at 81–83 μΩ, whereas field-served contacts showed displacement-sensitive, non-monotonic resistance changes. A finite element model of 24 contact fingers with assembly-induced prestress was developed. Contact pressures were calculated under normal, settlement, and combined settlement—horizontal displacement conditions. Normal force was integrated over each contact area, and zero pressure denoted contact loss. The force, contact length, and equivalent contact width were used in a cylinder-on-flat model to calculate finger resistance. These resistances were connected in parallel and calibrated against the measured normal-state resistance of 83.57 μΩ. Settlement redistributed load from lower to upper fingers, while further horizontal displacement concentrated contact on one side; eastward displacement caused all bottom-row fingers to lose contact. Electrothermal simulation showed little temperature change while most fingers remained in contact, but temperatures exceeded 130 °C after bottom-row contact loss. Thus, total resistance can conceal local degradation, while load redistribution and current concentration increase Joule heating in remaining paths and explain burnout.
Open AccessElectrothermal Failure Mechanism of Multi-Finger Contacts in a Disconnector Under Foundation-Induced Displacement
To clarify the electrothermal failure of fixed contacts in a 363 kV three-phase five-column disconnector, field inspection, circuit-resistance tests, contact-mechanical modeling, finger-level resistance calculation, and electrothermal simulation were combined. The fault side had approximately 10 mm settlement and 51 mm horizontal displacement. Unserved contacts remained at 81–83 μΩ, whereas field-served contacts showed displacement-sensitive, non-monotonic resistance changes. A finite element model of 24 contact fingers with assembly-induced prestress was developed. Contact pressures were calculated under normal, settlement, and combined settlement—horizontal displacement conditions. Normal force was integrated over each contact area, and zero pressure denoted contact loss. The force, contact length, and equivalent contact width were used in a cylinder-on-flat model to calculate finger resistance. These resistances were connected in parallel and calibrated against the measured normal-state resistance of 83.57 μΩ. Settlement redistributed load from lower to upper fingers, while further horizontal displacement concentrated contact on one side; eastward displacement caused all bottom-row fingers to lose contact. Electrothermal simulation showed little temperature change while most fingers remained in contact, but temperatures exceeded 130 °C after bottom-row contact loss. Thus, total resistance can conceal local degradation, while load redistribution and current concentration increase Joule heating in remaining paths and explain burnout.
- Open Access
- 17 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (16) , 3659
Collaborative Suppression Method Based on Current Preprocessing and Active Power Decoupling for Second-Order DC Voltage Ripple in PFC Converters
This paper presents a collaborative second-order voltage ripple suppression control method for single-phase power factor correction (PFC) converters. First, the causes of second-order DC output voltage ripples are analyzed. Then a modified current preprocessing mechanism is presented for the PFC in order to elevate valley power and suppress peak power, which is able to reduce the second-order power fluctuations. Parameter design and constraints are further provided to obtain a reasonable trade-off between current distortion and the suppressing effect. Meanwhile, an active power decoupling (APD) circuit reusing a capacitor half-bridge is also embedded into the PFC converter. For the APD circuit, this paper calculates and determines the capacitor voltage reference for the purpose of absorbing second-order power fluctuations. Moreover, a closed-loop control strategy for APD is presented to achieve tracking of the capacitor voltage. A coordinate control algorithm is introduced to monitor the cooperative relationship between PFC and APD control. Finally, a 400 W PFC prototype is constructed, and experimental tests are then carried out for verification. The results obtained based on the prototype can confirm the feasibility of the control strategy and the correctness of the theoretical analysis discussed in this paper.
- 17 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (16) , 3659
Open AccessCollaborative Suppression Method Based on Current Preprocessing and Active Power Decoupling for Second-Order DC Voltage Ripple in PFC Converters
This paper presents a collaborative second-order voltage ripple suppression control method for single-phase power factor correction (PFC) converters. First, the causes of second-order DC output voltage ripples are analyzed. Then a modified current preprocessing mechanism is presented for the PFC in order to elevate valley power and suppress peak power, which is able to reduce the second-order power fluctuations. Parameter design and constraints are further provided to obtain a reasonable trade-off between current distortion and the suppressing effect. Meanwhile, an active power decoupling (APD) circuit reusing a capacitor half-bridge is also embedded into the PFC converter. For the APD circuit, this paper calculates and determines the capacitor voltage reference for the purpose of absorbing second-order power fluctuations. Moreover, a closed-loop control strategy for APD is presented to achieve tracking of the capacitor voltage. A coordinate control algorithm is introduced to monitor the cooperative relationship between PFC and APD control. Finally, a 400 W PFC prototype is constructed, and experimental tests are then carried out for verification. The results obtained based on the prototype can confirm the feasibility of the control strategy and the correctness of the theoretical analysis discussed in this paper.
- Open Access
- 14 March 2026
- Published by MDPI AG in Electronics
- Vol. 15 (6) , 1218
Transient Stability Enhancement and Voltage Support for Grid-Forming Converters via Adaptive Improved Observer Control Under Grid Fault
With the large-scale integration of renewable energy sources, grid-forming (GFM) converters with inherent voltage and frequency support capabilities have attracted significant attention. However, due to the limited overcurrent withstand capability of power electronic devices, the stable operation of GFM converters under grid faults such as grid voltage sags remains a critical challenge. To address this issue, this paper systematically investigates the mechanisms of power angle instability and overcurrent generation during grid faults by a unified equivalent impedance model. Based on this analysis, a comprehensive control strategy that simultaneously considers power angle stability and overcurrent suppression is proposed. By introducing an adaptive improved observer control (AIOC), the active power reference is adaptively adjusted to enhance the power angle stability of the system. Meanwhile, the voltage reference is dynamically regulated to effectively limit the fault current while enhancing the voltage support capability. Finally, comprehensive theoretical analysis and experimental validation are provided. The experimental results demonstrate that the proposed strategy is capable of ensuring power angle stability and limits the overcurrent to within 1.5 p.u. Meanwhile, the voltage magnitude is increased by approximately 6%. The results demonstrate the robustness and adaptability of the proposed method under various conditions.
- 14 March 2026
- Published by MDPI AG in Electronics
- Vol. 15 (6) , 1218
Open AccessTransient Stability Enhancement and Voltage Support for Grid-Forming Converters via Adaptive Improved Observer Control Under Grid Fault
With the large-scale integration of renewable energy sources, grid-forming (GFM) converters with inherent voltage and frequency support capabilities have attracted significant attention. However, due to the limited overcurrent withstand capability of power electronic devices, the stable operation of GFM converters under grid faults such as grid voltage sags remains a critical challenge. To address this issue, this paper systematically investigates the mechanisms of power angle instability and overcurrent generation during grid faults by a unified equivalent impedance model. Based on this analysis, a comprehensive control strategy that simultaneously considers power angle stability and overcurrent suppression is proposed. By introducing an adaptive improved observer control (AIOC), the active power reference is adaptively adjusted to enhance the power angle stability of the system. Meanwhile, the voltage reference is dynamically regulated to effectively limit the fault current while enhancing the voltage support capability. Finally, comprehensive theoretical analysis and experimental validation are provided. The experimental results demonstrate that the proposed strategy is capable of ensuring power angle stability and limits the overcurrent to within 1.5 p.u. Meanwhile, the voltage magnitude is increased by approximately 6%. The results demonstrate the robustness and adaptability of the proposed method under various conditions.
- 16 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (1) , 69-78
Bird Droppings Flashover Protection Range for 330 kV I-string Composite Insulators Considering Shielding Ring
When the radius of protection against bird droppings is determined for 330 kV insulators in line with the standard GB/T 35695-2017, the influence of the shielding ring is ignored. Also, bird droppings can’t be prevented from flashing accidents by the protection range with a radius of 0.85 m from the center of the insulator axis. Therefore, it is proposed in this paper to determine the bird droppings protection range (BDPR) by introducing a rotational scanning method along the shielding ring boundary. It is discovered that the average breakdown electric field strength (BEFS) of the residual air gap (RAG) is 3.38 kV/cm when the cotton cord rope end is above the cylindrical tube of the shielding ring, 3.0 kV/cm when the rope end is positioned on the outside of the cylindrical tube, and 2.7 kV/cm when the rope end is located on the outer-side of the curved tube of the shielding ring. The other three shielding rings are used to verify the universality of the proposed method in determining the range of protection against bird droppings flashover.
- 16 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (1) , 69-78
Bird Droppings Flashover Protection Range for 330 kV I-string Composite Insulators Considering Shielding Ring
When the radius of protection against bird droppings is determined for 330 kV insulators in line with the standard GB/T 35695-2017, the influence of the shielding ring is ignored. Also, bird droppings can’t be prevented from flashing accidents by the protection range with a radius of 0.85 m from the center of the insulator axis. Therefore, it is proposed in this paper to determine the bird droppings protection range (BDPR) by introducing a rotational scanning method along the shielding ring boundary. It is discovered that the average breakdown electric field strength (BEFS) of the residual air gap (RAG) is 3.38 kV/cm when the cotton cord rope end is above the cylindrical tube of the shielding ring, 3.0 kV/cm when the rope end is positioned on the outside of the cylindrical tube, and 2.7 kV/cm when the rope end is located on the outer-side of the curved tube of the shielding ring. The other three shielding rings are used to verify the universality of the proposed method in determining the range of protection against bird droppings flashover.
- 5 December 2024
- Published by Springer Nature
- p. 584-595
Fault and Abnormal Analysis of Circuit Breakers Pre-insertion Resistor and Reliability Improvement Measures
- 5 December 2024
- Published by Springer Nature
- p. 584-595
Fault and Abnormal Analysis of Circuit Breakers Pre-insertion Resistor and Reliability Improvement Measures
- Open Access
- 12 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 97938-97950
Analysis and Protection Studies of Bird Droppings Falling on the Electric Field Distribution Near the 330-kV Transmission Line V-Type Composite Insulators
Recently, the number of birds along the 330kV transmission lines in the northwest region has gradually increased. The frequency of birds nesting and excreting on the towers has been steadily rising, with bird droppings increasingly becoming the primary factor causing bird-related tripping faults. A three-dimensional model of the tower cross arm, continuous bird droppings, and insulators was constructed to simulate and analyze the impact characteristics of bird droplet diameter, length, and relative position to insulators on the spatial electric field near the insulators. Experimental corrections were made, and based on simulation and experimental results, a bird-proof baffle was designed. Research results indicate that under conditions of single-ended grounding and suspended droplets of bird droppings, the average electric field strength at the lower end of the bird droppings and the grading ring was extracted to define the protective area against irregular-shaped bird droppings. After experimental validation, a correction coefficient of 1.4 was obtained based on the experimental results. A square protective baffle with a diversion function was designed based on simulation and experimental results. Bird droppings were placed at the baffle’s diversion groove, and the average electric field strength between the lower end of the bird droppings and the grading ring was consistently lower than the breakdown field strength of 2.98 kV/cm. The research results of this paper can serve as a basis for the subsequent designing of physical models of bird-proof baffles and prevention of bird-related flashover faults on V-type insulators.
- 12 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 97938-97950
Open AccessAnalysis and Protection Studies of Bird Droppings Falling on the Electric Field Distribution Near the 330-kV Transmission Line V-Type Composite Insulators
Recently, the number of birds along the 330kV transmission lines in the northwest region has gradually increased. The frequency of birds nesting and excreting on the towers has been steadily rising, with bird droppings increasingly becoming the primary factor causing bird-related tripping faults. A three-dimensional model of the tower cross arm, continuous bird droppings, and insulators was constructed to simulate and analyze the impact characteristics of bird droplet diameter, length, and relative position to insulators on the spatial electric field near the insulators. Experimental corrections were made, and based on simulation and experimental results, a bird-proof baffle was designed. Research results indicate that under conditions of single-ended grounding and suspended droplets of bird droppings, the average electric field strength at the lower end of the bird droppings and the grading ring was extracted to define the protective area against irregular-shaped bird droppings. After experimental validation, a correction coefficient of 1.4 was obtained based on the experimental results. A square protective baffle with a diversion function was designed based on simulation and experimental results. Bird droppings were placed at the baffle’s diversion groove, and the average electric field strength between the lower end of the bird droppings and the grading ring was consistently lower than the breakdown field strength of 2.98 kV/cm. The research results of this paper can serve as a basis for the subsequent designing of physical models of bird-proof baffles and prevention of bird-related flashover faults on V-type insulators.
- Open Access
- 31 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 98376-98390
Analysis and Protection Studies of Bird Droppings on the Electric Field Distribution Near 330 kV Transmission Line Cathead Towers With Composite Insulators
The increase in bird populations along the Hexi Corridor has led to an increase in flashover faults on 330 kV transmission lines caused by bird droppings. To mitigate the issue of line tripping caused by bird droppings, it is necessary to analyze the distribution of the electric field near composite insulators during the process of bird droppings falling. A three-dimensional model, including the tower, bird droppings, and insulators, was created to assess the impact of bird droppings’ characteristics on the electric field near the insulators. Based on simulation results, a bird-proof cover was designed to modify the trajectory of the bird droppings’ path. The research found that when bird droppings are grounded and continuous, the most severe distortion of the residual air gap field occurs at a distance of 599.34 mm from the insulator axis. In the dynamic process of ungrounded and continuous bird droppings falling downward with a length less than 3200 mm, the electric field intensity in the residual air gap remains below 5.66 kV/cm outside the circular area centered at the insulator skirt with a radius of 740 mm. Based on the simulation results under both single-end grounded and ungrounded conditions of bird droppings, a bird-proof cover structure was devised to alter the location where bird droppings fall. After bird droppings fall along the edges of the bird-proof cover, the average electric field intensity between the bird droppings and the high-voltage terminal is maintained below 3.02 kV/cm. These research findings lay the foundation for subsequent fabrication of physical models of bird-proof covers.
- 31 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 98376-98390
Open AccessAnalysis and Protection Studies of Bird Droppings on the Electric Field Distribution Near 330 kV Transmission Line Cathead Towers With Composite Insulators
The increase in bird populations along the Hexi Corridor has led to an increase in flashover faults on 330 kV transmission lines caused by bird droppings. To mitigate the issue of line tripping caused by bird droppings, it is necessary to analyze the distribution of the electric field near composite insulators during the process of bird droppings falling. A three-dimensional model, including the tower, bird droppings, and insulators, was created to assess the impact of bird droppings’ characteristics on the electric field near the insulators. Based on simulation results, a bird-proof cover was designed to modify the trajectory of the bird droppings’ path. The research found that when bird droppings are grounded and continuous, the most severe distortion of the residual air gap field occurs at a distance of 599.34 mm from the insulator axis. In the dynamic process of ungrounded and continuous bird droppings falling downward with a length less than 3200 mm, the electric field intensity in the residual air gap remains below 5.66 kV/cm outside the circular area centered at the insulator skirt with a radius of 740 mm. Based on the simulation results under both single-end grounded and ungrounded conditions of bird droppings, a bird-proof cover structure was devised to alter the location where bird droppings fall. After bird droppings fall along the edges of the bird-proof cover, the average electric field intensity between the bird droppings and the high-voltage terminal is maintained below 3.02 kV/cm. These research findings lay the foundation for subsequent fabrication of physical models of bird-proof covers.
- Open Access
- 1 July 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 394 (4) , 042129
Realization of Harmonic Impedance Simulation Calculation Method for Grounding Grid in Substation
There is a difference between the actual impedance of substations' ground grid under harmonic interference and that measured under power frequency. Especially under strong harmonic interference, the difference becomes more obvious between the actual one and that measured under power frequency. A method is proposed in this paper to calculate parameters of ground grid models by measuring the ground grid impedances under power frequency and then calculate those under harmonic interference. This method is capable of solving the problem that it is impossible to measure the actual grounding impedance of substations operating under harmonic waves. The feasibility of the method is verified by means of simulating calculations. After correcting by this method, the grounding impedance modulus error becomes less than 2% and the impedance angle error less than 10%. This method may be applied to the measurement and analysis of grounding impedances of substations under harmonic interference.
- 1 July 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 394 (4) , 042129
Open AccessRealization of Harmonic Impedance Simulation Calculation Method for Grounding Grid in Substation
There is a difference between the actual impedance of substations' ground grid under harmonic interference and that measured under power frequency. Especially under strong harmonic interference, the difference becomes more obvious between the actual one and that measured under power frequency. A method is proposed in this paper to calculate parameters of ground grid models by measuring the ground grid impedances under power frequency and then calculate those under harmonic interference. This method is capable of solving the problem that it is impossible to measure the actual grounding impedance of substations operating under harmonic waves. The feasibility of the method is verified by means of simulating calculations. After correcting by this method, the grounding impedance modulus error becomes less than 2% and the impedance angle error less than 10%. This method may be applied to the measurement and analysis of grounding impedances of substations under harmonic interference.