Jianqiao Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jianqiao Ma has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Shuyao Zhang
Department of Power Engineering, School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, China
4 shared publications - Kang Liu
State Grid Gansu Electric Power Research Institute, Lanzhou 730070, China
3 shared publications - Ruiqian Zhang
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
3 shared publications - Xiangfei Wang
Department of Power Engineering, School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, China
3 shared publications - Yihu Wang
State Grid Gansu Electric Power Research Institute, Lanzhou, China
3 shared publications - Yudi Fan
Department of Power Engineering, School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, China
3 shared publications
Latest Publications
- 29 October 2026
- Published by Wiley in Polymer Engineering & Science
Enhancing the Comprehensive Properties of Polypropylene Films via Organic–Inorganic Interfacial Molecular Engineering
As an important insulating medium for high‐voltage direct‐current transmission capacitors, polypropylene (PP) film requires the synergistic optimization of its insulating properties, dielectric properties, and thermal stability to enhance the reliability of capacitor equipment. While doping the PP matrix with nanoparticles can effectively increase the material's relative permittivity, issues such as agglomeration and interfacial incompatibility lead to reduced dielectric strength and thermal stability. Based on this, this paper proposes an organic–inorganic interface molecular engineering strategy to improve the interfacial compatibility between nanoparticles and PP, and to construct deep‐level charge traps to suppress leakage current, thereby achieving a synergistic enhancement of the material's relative permittivity, dielectric strength, and thermal stability. PP/INA‐Al 2 O 3 composite films with different doping concentrations were prepared by surface‐treating nano‐Al 2 O 3 with isonicotinic acid (INA). Experimental results indicate that INA‐Al 2 O 3 doping effectively enhances the film's crystallinity. The PP/INA‐Al 2 O 3 film with 1.0 wt% doping achieved a breakdown strength of 562.44 kV/mm at room temperature, representing an approximately 35% increase compared to pure PP. At 85°C, the breakdown strength reached 528.17 kV/mm, demonstrating excellent insulation stability and thermal stability. Furthermore, the relative permittivity of PP/INA‐ Al 2 O 3 was also significantly higher than that of pure PP.
- 29 October 2026
- Published by Wiley in Polymer Engineering & Science
Enhancing the Comprehensive Properties of Polypropylene Films via Organic–Inorganic Interfacial Molecular Engineering
As an important insulating medium for high‐voltage direct‐current transmission capacitors, polypropylene (PP) film requires the synergistic optimization of its insulating properties, dielectric properties, and thermal stability to enhance the reliability of capacitor equipment. While doping the PP matrix with nanoparticles can effectively increase the material's relative permittivity, issues such as agglomeration and interfacial incompatibility lead to reduced dielectric strength and thermal stability. Based on this, this paper proposes an organic–inorganic interface molecular engineering strategy to improve the interfacial compatibility between nanoparticles and PP, and to construct deep‐level charge traps to suppress leakage current, thereby achieving a synergistic enhancement of the material's relative permittivity, dielectric strength, and thermal stability. PP/INA‐Al 2 O 3 composite films with different doping concentrations were prepared by surface‐treating nano‐Al 2 O 3 with isonicotinic acid (INA). Experimental results indicate that INA‐Al 2 O 3 doping effectively enhances the film's crystallinity. The PP/INA‐Al 2 O 3 film with 1.0 wt% doping achieved a breakdown strength of 562.44 kV/mm at room temperature, representing an approximately 35% increase compared to pure PP. At 85°C, the breakdown strength reached 528.17 kV/mm, demonstrating excellent insulation stability and thermal stability. Furthermore, the relative permittivity of PP/INA‐ Al 2 O 3 was also significantly higher than that of pure PP.
- 25 February 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (3) , 192
CIA-YOLO: multi-type insulator defect detection in transmission systems under sophisticated climatic conditions based on improved YOLOv8 algorithm
- 25 February 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (3) , 192
CIA-YOLO: multi-type insulator defect detection in transmission systems under sophisticated climatic conditions based on improved YOLOv8 algorithm
- 20 November 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 253
Bird droppings flashover faults analysis of 330 kV transmission line V-Shaped insulator strings
- 20 November 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 253
Bird droppings flashover faults analysis of 330 kV transmission line V-Shaped insulator strings
- 16 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (1) , 69-78
Bird Droppings Flashover Protection Range for 330 kV I-string Composite Insulators Considering Shielding Ring
When the radius of protection against bird droppings is determined for 330 kV insulators in line with the standard GB/T 35695-2017, the influence of the shielding ring is ignored. Also, bird droppings can’t be prevented from flashing accidents by the protection range with a radius of 0.85 m from the center of the insulator axis. Therefore, it is proposed in this paper to determine the bird droppings protection range (BDPR) by introducing a rotational scanning method along the shielding ring boundary. It is discovered that the average breakdown electric field strength (BEFS) of the residual air gap (RAG) is 3.38 kV/cm when the cotton cord rope end is above the cylindrical tube of the shielding ring, 3.0 kV/cm when the rope end is positioned on the outside of the cylindrical tube, and 2.7 kV/cm when the rope end is located on the outer-side of the curved tube of the shielding ring. The other three shielding rings are used to verify the universality of the proposed method in determining the range of protection against bird droppings flashover.
- 16 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (1) , 69-78
Bird Droppings Flashover Protection Range for 330 kV I-string Composite Insulators Considering Shielding Ring
When the radius of protection against bird droppings is determined for 330 kV insulators in line with the standard GB/T 35695-2017, the influence of the shielding ring is ignored. Also, bird droppings can’t be prevented from flashing accidents by the protection range with a radius of 0.85 m from the center of the insulator axis. Therefore, it is proposed in this paper to determine the bird droppings protection range (BDPR) by introducing a rotational scanning method along the shielding ring boundary. It is discovered that the average breakdown electric field strength (BEFS) of the residual air gap (RAG) is 3.38 kV/cm when the cotton cord rope end is above the cylindrical tube of the shielding ring, 3.0 kV/cm when the rope end is positioned on the outside of the cylindrical tube, and 2.7 kV/cm when the rope end is located on the outer-side of the curved tube of the shielding ring. The other three shielding rings are used to verify the universality of the proposed method in determining the range of protection against bird droppings flashover.
- 1 September 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (9)
Influence mechanism of cable terminal on airflow and leeward pollution distribution of high-speed train roof post insulator
The airflow around the high-speed train roof insulator modifies the distribution of fan-shaped, non-uniform contamination on the umbrella skirts, and the flashover voltage decreases as surface contamination becomes more uneven. Wind tunnel tests at 55 m/s show that the presence of a cable terminal significantly alters the leeward pollution distribution compared with a single post insulator. To investigate the underlying mechanism, an Euler–Euler two-phase flow model including both the cable terminal and the insulator was developed. Simulations reveal that airflow upwash and downwash on the leeward side of the insulator modify spanwise and streamwise flow patterns and the passage width between umbrella skirts, thereby shifting the boundaries of heavily polluted zones. Pollution accumulation experiments of 3 D-printed scale models confirmed the predictive capability of this approach. These results clarify how nearby structures influence airflow–pollution interactions and provide guidance for evaluating leeward pollution characteristics, optimizing insulator layouts, and understanding flashover behavior under non-uniform contamination conditions.
- 1 September 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (9)
Influence mechanism of cable terminal on airflow and leeward pollution distribution of high-speed train roof post insulator
The airflow around the high-speed train roof insulator modifies the distribution of fan-shaped, non-uniform contamination on the umbrella skirts, and the flashover voltage decreases as surface contamination becomes more uneven. Wind tunnel tests at 55 m/s show that the presence of a cable terminal significantly alters the leeward pollution distribution compared with a single post insulator. To investigate the underlying mechanism, an Euler–Euler two-phase flow model including both the cable terminal and the insulator was developed. Simulations reveal that airflow upwash and downwash on the leeward side of the insulator modify spanwise and streamwise flow patterns and the passage width between umbrella skirts, thereby shifting the boundaries of heavily polluted zones. Pollution accumulation experiments of 3 D-printed scale models confirmed the predictive capability of this approach. These results clarify how nearby structures influence airflow–pollution interactions and provide guidance for evaluating leeward pollution characteristics, optimizing insulator layouts, and understanding flashover behavior under non-uniform contamination conditions.
- 13 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (1) , 568-577
Analysis of Airflow Distribution and Upper Surface Heavily Polluted Areas on Series Double-Column Isolating Switch Insulators for EMUs
When the heavily polluted zones (HPZs) on the leeward side of the high voltage isolating switch insulators (HVISIs) on the high-speed train roof increases, the flashover voltage decreases, thereby increasing the risk of interrupting the train’s power supply. This paper proposes proportion of heavily polluted areas (PHPA) calculation method based on the circumferential angle α, which corresponds to the lowest pressure points, and the circumferential angle β, which corresponds to the boundary layer separation points. The results show that the PHPA for both the upstream insulator (UI) and the downstream insulator (DI) is less than 29.2%. The HPZs on the leeward side of the UI are symmetrically distributed along the flow direction centerline. In contrast, the leeward HPZs of the DI, affected by the wake of the UI, are asymmetrical. The PHPA derived from α is greater than the experimental result, while that obtained from β is smaller than the experimental result. The relative difference between the average value derived from α and β is less than 13.9% compared to the experimental result, the universality of the proposed calculation method was verified with other series double-column insulators. The proposed calculation method can effectively reduce the experimental workload when measuring HPZs, and it can also provide a reference for the preliminary work on structural optimization design for new anti-pollution insulators.
- 13 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (1) , 568-577
Analysis of Airflow Distribution and Upper Surface Heavily Polluted Areas on Series Double-Column Isolating Switch Insulators for EMUs
When the heavily polluted zones (HPZs) on the leeward side of the high voltage isolating switch insulators (HVISIs) on the high-speed train roof increases, the flashover voltage decreases, thereby increasing the risk of interrupting the train’s power supply. This paper proposes proportion of heavily polluted areas (PHPA) calculation method based on the circumferential angle α, which corresponds to the lowest pressure points, and the circumferential angle β, which corresponds to the boundary layer separation points. The results show that the PHPA for both the upstream insulator (UI) and the downstream insulator (DI) is less than 29.2%. The HPZs on the leeward side of the UI are symmetrically distributed along the flow direction centerline. In contrast, the leeward HPZs of the DI, affected by the wake of the UI, are asymmetrical. The PHPA derived from α is greater than the experimental result, while that obtained from β is smaller than the experimental result. The relative difference between the average value derived from α and β is less than 13.9% compared to the experimental result, the universality of the proposed calculation method was verified with other series double-column insulators. The proposed calculation method can effectively reduce the experimental workload when measuring HPZs, and it can also provide a reference for the preliminary work on structural optimization design for new anti-pollution insulators.
- 6 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 2393-2402
Umbrella Skirt Design of Oblique Cantilever Composite Insulator Suppressing Icicle Bridging for High-Speed Railway
When icing occurs on the oblique cantilever insulator of the high-speed railway contact line, the ice column that develops downward from the edge of the small umbrella connects with the edge or surface of the large umbrella, which can reduce the creepage distance and even induce flashover failures in the insulator. This paper designs an irregular umbrella skirt oblique cantilever insulator, oriented vertically to the horizontal plane, based on an analysis of the droplet sliding trajectory and ice column growth process on the surface of existing oblique cantilever insulators. A model of the irregular umbrella insulator is produced using 3D printing, and its surface is coated with RTV. Experimental results show that, during droplet sliding on the optimized irregular umbrella skirt surface, the large umbrella of the irregular umbrella insulator is not bridged by the ice column. Compared to the original insulator model, the flashover voltage of the oversized umbrella irregular umbrella insulator model is increased by 5.44 kV. The research findings can provide a reference for reducing icing flashover failures in oblique cantilever insulators under low-temperature and high-humidity environments.
- 6 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 2393-2402
Umbrella Skirt Design of Oblique Cantilever Composite Insulator Suppressing Icicle Bridging for High-Speed Railway
When icing occurs on the oblique cantilever insulator of the high-speed railway contact line, the ice column that develops downward from the edge of the small umbrella connects with the edge or surface of the large umbrella, which can reduce the creepage distance and even induce flashover failures in the insulator. This paper designs an irregular umbrella skirt oblique cantilever insulator, oriented vertically to the horizontal plane, based on an analysis of the droplet sliding trajectory and ice column growth process on the surface of existing oblique cantilever insulators. A model of the irregular umbrella insulator is produced using 3D printing, and its surface is coated with RTV. Experimental results show that, during droplet sliding on the optimized irregular umbrella skirt surface, the large umbrella of the irregular umbrella insulator is not bridged by the ice column. Compared to the original insulator model, the flashover voltage of the oversized umbrella irregular umbrella insulator model is increased by 5.44 kV. The research findings can provide a reference for reducing icing flashover failures in oblique cantilever insulators under low-temperature and high-humidity environments.
- 2 November 2024
- Published by Springer Nature in Journal of Real-Time Image Processing
- Vol. 21 (6) , 1-13
An improved insulator self-explosion detection method based on group-level pruning for the YOLOv7-tiny algorithm
- 2 November 2024
- Published by Springer Nature in Journal of Real-Time Image Processing
- Vol. 21 (6) , 1-13
An improved insulator self-explosion detection method based on group-level pruning for the YOLOv7-tiny algorithm
- Open Access
- 12 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 97938-97950
Analysis and Protection Studies of Bird Droppings Falling on the Electric Field Distribution Near the 330-kV Transmission Line V-Type Composite Insulators
Recently, the number of birds along the 330kV transmission lines in the northwest region has gradually increased. The frequency of birds nesting and excreting on the towers has been steadily rising, with bird droppings increasingly becoming the primary factor causing bird-related tripping faults. A three-dimensional model of the tower cross arm, continuous bird droppings, and insulators was constructed to simulate and analyze the impact characteristics of bird droplet diameter, length, and relative position to insulators on the spatial electric field near the insulators. Experimental corrections were made, and based on simulation and experimental results, a bird-proof baffle was designed. Research results indicate that under conditions of single-ended grounding and suspended droplets of bird droppings, the average electric field strength at the lower end of the bird droppings and the grading ring was extracted to define the protective area against irregular-shaped bird droppings. After experimental validation, a correction coefficient of 1.4 was obtained based on the experimental results. A square protective baffle with a diversion function was designed based on simulation and experimental results. Bird droppings were placed at the baffle’s diversion groove, and the average electric field strength between the lower end of the bird droppings and the grading ring was consistently lower than the breakdown field strength of 2.98 kV/cm. The research results of this paper can serve as a basis for the subsequent designing of physical models of bird-proof baffles and prevention of bird-related flashover faults on V-type insulators.
- 12 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 97938-97950
Open AccessAnalysis and Protection Studies of Bird Droppings Falling on the Electric Field Distribution Near the 330-kV Transmission Line V-Type Composite Insulators
Recently, the number of birds along the 330kV transmission lines in the northwest region has gradually increased. The frequency of birds nesting and excreting on the towers has been steadily rising, with bird droppings increasingly becoming the primary factor causing bird-related tripping faults. A three-dimensional model of the tower cross arm, continuous bird droppings, and insulators was constructed to simulate and analyze the impact characteristics of bird droplet diameter, length, and relative position to insulators on the spatial electric field near the insulators. Experimental corrections were made, and based on simulation and experimental results, a bird-proof baffle was designed. Research results indicate that under conditions of single-ended grounding and suspended droplets of bird droppings, the average electric field strength at the lower end of the bird droppings and the grading ring was extracted to define the protective area against irregular-shaped bird droppings. After experimental validation, a correction coefficient of 1.4 was obtained based on the experimental results. A square protective baffle with a diversion function was designed based on simulation and experimental results. Bird droppings were placed at the baffle’s diversion groove, and the average electric field strength between the lower end of the bird droppings and the grading ring was consistently lower than the breakdown field strength of 2.98 kV/cm. The research results of this paper can serve as a basis for the subsequent designing of physical models of bird-proof baffles and prevention of bird-related flashover faults on V-type insulators.