Shuyao Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shuyao Zhang has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Jianqiao Ma
Department of Electrical Engineering, School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, China
4 shared publications - Caiya Chen
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
2 shared publications - Kang Liu
State Grid Gansu Electric Power Research Institute, Lanzhou 730070, China
1 shared publication Mengfei Liang
State Grid Gansu Electric Power Company 2 , Lanzhou 730000, Gansu Province
1 shared publication- Min Hou
Department of Power Engineering, School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, China
1 shared publication Mingxing Tian
Department of Power Engineering, School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, China
1 shared publication
Latest Publications
- 16 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (1) , 69-78
Bird Droppings Flashover Protection Range for 330 kV I-string Composite Insulators Considering Shielding Ring
When the radius of protection against bird droppings is determined for 330 kV insulators in line with the standard GB/T 35695-2017, the influence of the shielding ring is ignored. Also, bird droppings can’t be prevented from flashing accidents by the protection range with a radius of 0.85 m from the center of the insulator axis. Therefore, it is proposed in this paper to determine the bird droppings protection range (BDPR) by introducing a rotational scanning method along the shielding ring boundary. It is discovered that the average breakdown electric field strength (BEFS) of the residual air gap (RAG) is 3.38 kV/cm when the cotton cord rope end is above the cylindrical tube of the shielding ring, 3.0 kV/cm when the rope end is positioned on the outside of the cylindrical tube, and 2.7 kV/cm when the rope end is located on the outer-side of the curved tube of the shielding ring. The other three shielding rings are used to verify the universality of the proposed method in determining the range of protection against bird droppings flashover.
- 16 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (1) , 69-78
Bird Droppings Flashover Protection Range for 330 kV I-string Composite Insulators Considering Shielding Ring
When the radius of protection against bird droppings is determined for 330 kV insulators in line with the standard GB/T 35695-2017, the influence of the shielding ring is ignored. Also, bird droppings can’t be prevented from flashing accidents by the protection range with a radius of 0.85 m from the center of the insulator axis. Therefore, it is proposed in this paper to determine the bird droppings protection range (BDPR) by introducing a rotational scanning method along the shielding ring boundary. It is discovered that the average breakdown electric field strength (BEFS) of the residual air gap (RAG) is 3.38 kV/cm when the cotton cord rope end is above the cylindrical tube of the shielding ring, 3.0 kV/cm when the rope end is positioned on the outside of the cylindrical tube, and 2.7 kV/cm when the rope end is located on the outer-side of the curved tube of the shielding ring. The other three shielding rings are used to verify the universality of the proposed method in determining the range of protection against bird droppings flashover.
- 1 September 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (9)
Influence mechanism of cable terminal on airflow and leeward pollution distribution of high-speed train roof post insulator
The airflow around the high-speed train roof insulator modifies the distribution of fan-shaped, non-uniform contamination on the umbrella skirts, and the flashover voltage decreases as surface contamination becomes more uneven. Wind tunnel tests at 55 m/s show that the presence of a cable terminal significantly alters the leeward pollution distribution compared with a single post insulator. To investigate the underlying mechanism, an Euler–Euler two-phase flow model including both the cable terminal and the insulator was developed. Simulations reveal that airflow upwash and downwash on the leeward side of the insulator modify spanwise and streamwise flow patterns and the passage width between umbrella skirts, thereby shifting the boundaries of heavily polluted zones. Pollution accumulation experiments of 3 D-printed scale models confirmed the predictive capability of this approach. These results clarify how nearby structures influence airflow–pollution interactions and provide guidance for evaluating leeward pollution characteristics, optimizing insulator layouts, and understanding flashover behavior under non-uniform contamination conditions.
- 1 September 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (9)
Influence mechanism of cable terminal on airflow and leeward pollution distribution of high-speed train roof post insulator
The airflow around the high-speed train roof insulator modifies the distribution of fan-shaped, non-uniform contamination on the umbrella skirts, and the flashover voltage decreases as surface contamination becomes more uneven. Wind tunnel tests at 55 m/s show that the presence of a cable terminal significantly alters the leeward pollution distribution compared with a single post insulator. To investigate the underlying mechanism, an Euler–Euler two-phase flow model including both the cable terminal and the insulator was developed. Simulations reveal that airflow upwash and downwash on the leeward side of the insulator modify spanwise and streamwise flow patterns and the passage width between umbrella skirts, thereby shifting the boundaries of heavily polluted zones. Pollution accumulation experiments of 3 D-printed scale models confirmed the predictive capability of this approach. These results clarify how nearby structures influence airflow–pollution interactions and provide guidance for evaluating leeward pollution characteristics, optimizing insulator layouts, and understanding flashover behavior under non-uniform contamination conditions.
- 6 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 2393-2402
Umbrella Skirt Design of Oblique Cantilever Composite Insulator Suppressing Icicle Bridging for High-Speed Railway
When icing occurs on the oblique cantilever insulator of the high-speed railway contact line, the ice column that develops downward from the edge of the small umbrella connects with the edge or surface of the large umbrella, which can reduce the creepage distance and even induce flashover failures in the insulator. This paper designs an irregular umbrella skirt oblique cantilever insulator, oriented vertically to the horizontal plane, based on an analysis of the droplet sliding trajectory and ice column growth process on the surface of existing oblique cantilever insulators. A model of the irregular umbrella insulator is produced using 3D printing, and its surface is coated with RTV. Experimental results show that, during droplet sliding on the optimized irregular umbrella skirt surface, the large umbrella of the irregular umbrella insulator is not bridged by the ice column. Compared to the original insulator model, the flashover voltage of the oversized umbrella irregular umbrella insulator model is increased by 5.44 kV. The research findings can provide a reference for reducing icing flashover failures in oblique cantilever insulators under low-temperature and high-humidity environments.
- 6 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 2393-2402
Umbrella Skirt Design of Oblique Cantilever Composite Insulator Suppressing Icicle Bridging for High-Speed Railway
When icing occurs on the oblique cantilever insulator of the high-speed railway contact line, the ice column that develops downward from the edge of the small umbrella connects with the edge or surface of the large umbrella, which can reduce the creepage distance and even induce flashover failures in the insulator. This paper designs an irregular umbrella skirt oblique cantilever insulator, oriented vertically to the horizontal plane, based on an analysis of the droplet sliding trajectory and ice column growth process on the surface of existing oblique cantilever insulators. A model of the irregular umbrella insulator is produced using 3D printing, and its surface is coated with RTV. Experimental results show that, during droplet sliding on the optimized irregular umbrella skirt surface, the large umbrella of the irregular umbrella insulator is not bridged by the ice column. Compared to the original insulator model, the flashover voltage of the oversized umbrella irregular umbrella insulator model is increased by 5.44 kV. The research findings can provide a reference for reducing icing flashover failures in oblique cantilever insulators under low-temperature and high-humidity environments.