The effect of a pre-reconstruction process in a filtered back projection reconstruction on an image quality of a low tube voltage computed tomography
- 15 December 2023
- journal article
- research article
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 17 (1) , 306-314
Abstract
This study aims to evaluate the effect of pre-reconstruction process for low tube voltage computed tomography (CT) on image quality of filtered back projection (FBP) reconstruction. Small and large quality assurance water phantoms (19 and 33 cm diameter) were scanned on a third-generation dual-source CT with 70 kVp and 120 kVp at various dose levels. Image quality was assessed in terms of the noise power spectrum (NPS) and task-based transfer function (TTF). NPSs and TTFs in the small phantom were comparable between 70 and 120 kVp protocols. In the large phantom, the curves of the NPS changed and the TTF decreased even at the high-dose levels for 70 kVp protocol compared to 120 kVp protocol. Our results indicated that the pre-reconstruction process is performed in low tube voltage CT for large objects even for the FBP reconstruction and has an effect on the image quality.Keywords
This publication has 16 references indexed in Scilit:
- Low-tube-voltage selection for non-contrast-enhanced CT: Comparison of the radiation dose in pediatric and adult phantomsPhysica Medica, 2016
- The influence of focal spot blooming on high‐contrast spatial resolution in CT imagingMedical Physics, 2015
- Characteristic image quality of a third generation dual‐source MDCT scanner: Noise, resolution, and detectabilityMedical Physics, 2015
- Assessment of volumetric noise and resolution performance for linear and nonlinear CT reconstruction methodsMedical Physics, 2014
- Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom studyEuropean Radiology, 2014
- Effect of Tube Voltage on CT Noise Levels in Different Phantom SizesAmerican Journal of Roentgenology, 2013
- Towards task-based assessment of CT performance: System and object MTF across different reconstruction algorithmsMedical Physics, 2012
- Abdominal Dynamic CT in Patients with Renal Dysfunction: Contrast Agent Dose Reduction with Low Tube Voltage and High Tube Current–Time Product Settings at 256–Detector Row CTRadiology, 2011
- Adaptive noise reduction toward low-dose computed tomography2003
- Generalized multi‐dimensional adaptive filtering for conventional and spiral single‐slice, multi‐slice, and cone‐beam CTMedical Physics, 2001