KTKazuki Takegami

Kazuki Takegami

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kazuki Takegami has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of an Active-Type Optically Stimulated Luminescence (OSL) Dosimeter for Real-Time Dose Measurement of Diagnostic X-Rays

    by Sota Goto, Takuya Kasue, Keiji Takahisa, Takashi Asahara, Natsumi Kimoto, Rina Nishigami, Daiki Kobayashi, Kazuki Takegami, Hiroaki Hayashi

    Active-type radiation dosimeters can measure list-mode datasets related to the measurement time and exposure dose, which contribute to detailed analysis of radiation exposure for patients and clinical staff. The aim of this study is to develop a compact active-type dosimeter based on an optically stimulated luminescence (OSL) system, and to establish a dose measurement procedure for diagnostic X-rays. The proposed dosimeter consists of an OSL sheet made of Al2O3:C and a multi-pixel photon counter (MPPC), and the detector region dimension is 10 mm × 10 mm × 13 mm. List-mode datasets consisting of measurement time and pulse height were recorded. The accumulated signal was analyzed by integrating the pulse-height data, in which the processing for smoothing, recovery-time correction, and counting-loss correction were performed. A dose calibration curve was determined from the integrated signal and reference air kerma measured with an ionization chamber. System performance was evaluated using diagnostic X-ray equipment under various dose rate conditions: a tube voltage of 80 kV, tube currents of 20–160 mA, and an exposure time of 1.0 s. Clinical applicability was also verified under typical exposure conditions for hand (50 kV), abdominal (80 kV), and chest (120 kV) examinations. In the experimental results, it was found that the proposed dosimeter can appropriately measure list-mode datasets and determine the accumulated dose with an accuracy of ±20% for 0.3–10 mGy/s. These findings indicate that the proposed dosimeter can be used for clinical dosimetry during diagnostic X-ray examinations.

  • Open Access

    Applicability of Effective Atomic Number (Z eff) Image Analysis of Coronary Plaques Measured With Photon- Counting Computed Tomography

    by Takashi Asahara, Mana Mitani, Natsumi Kimoto, Rina Nishigami, Kazuki Takegami, Yusuke Morimitsu, Noriaki Akagi, Toru Miyoshi, Yuki Kanazawa, Toshihiro Iguchi, et al.

    Objective: Coronary computed tomography (CT) allows the assessment of cardiovascular risk by imaging calcified plaques in coronary arteries. Because photon-counting CT (PC-CT) can analyze the effective atomic number (Z eff) of the subject, it is expected to be applied to the analysis of plaque components. The purpose of this study was to investigate the applicability of plaque analysis based on Z eff images with continuous gradation. Methods: Z eff images were generated from virtual monoenergetic images (VMIs) obtained by PC-CT. Z eff values were derived from the difference between linear attenuation coefficients (μ) at low and high energies using an in-house program. Coronary CT images of 64 plaques in 10 patients were analyzed. The Z eff score, calculated as the sum of Z eff values within the plaque region, was calculated and compared with the conventional Agatston score and mean coronary artery calcium (CAC) score. Results: The systematic uncertainty of Z eff images was estimated to be ±0.08. The Z eff score of actual patient data showed strong positive correlations with the conventional Agatston and mean CAC scores. The Z eff score uses all voxel data in the plaque area, whereas conventional scores consider only data from voxels with a CT value >130. We found that the conventional scores excluded 39% of the plaque area, and the Z eff score permitted the analysis of low- and high-density plaques. Conclusions: Z eff imaging was shown to be applicable to plaque analysis that reflects the entire plaque volume. This study demonstrated its technical feasibility as a compositional analysis method using the Z eff image.


  • Standardization of image quality in dynamic chest radiography: a determination procedure of individualized exposure settings based on the data from plain chest radiography

    by Hiroaki Tsutsumi, Kazuki Takegami, Taiga Miura, Masaki Takemitsu, Ayumi Takegami, Shohei Kudomi, Sono Kanoya, Tsunahiko Hirano, Kazuto Matsunaga

    In plain chest radiography (CXR), automatic exposure control (AEC) is generally used to standardize image quality. In contrast, dynamic chest radiography (DCR) systems preliminarily require manual setting of tube current–time products (mAs value). Body mass index (BMI) of patients is one of the indexes to determine the mAs value; however, standardization is limited because the anatomical differences are not considered. In this study, for further standardization, we propose a practical procedure to determine the individual mAs value of DCR using data obtained from CXR. To evaluate its effectiveness, we retrospectively analyzed 97 patients who underwent both CXR and DCR on the same day. DCR was performed in the following procedures: (1) obtain the relationship between the mAs value and the exposure indicator (S value, Konica Minolta, Inc.) obtained in CXR acquisition, (2) calculate the mAs value of DCR for the target S value of 2500, and (3) record the S value in DCR. The tube voltages for CXR and DCR were set to 120 kV and 100 kV with a copper filter, respectively. The differences in exposure doses were corrected by measuring the air kerma using a CdTe detector. As a result, the S values of CXR and DCR were 133 ± 13 (Coefficient of Variation (CV) = 9.9%) and 2629 ± 207 (CV = 7.9%), respectively, which were not dependent on the patient size based on evaluating the S values of five classified BMI groups. In conclusion, our proposed procedure enables standardization of the image quality in DCR by optimizing the patient-specific exposure conditions.


  • The effect of a pre-reconstruction process in a filtered back projection reconstruction on an image quality of a low tube voltage computed tomography

    by Masaki Takemitsu, Shohei Kudomi, Kazuki Takegami, Takuya Uehara

    This study aims to evaluate the effect of pre-reconstruction process for low tube voltage computed tomography (CT) on image quality of filtered back projection (FBP) reconstruction. Small and large quality assurance water phantoms (19 and 33 cm diameter) were scanned on a third-generation dual-source CT with 70 kVp and 120 kVp at various dose levels. Image quality was assessed in terms of the noise power spectrum (NPS) and task-based transfer function (TTF). NPSs and TTFs in the small phantom were comparable between 70 and 120 kVp protocols. In the large phantom, the curves of the NPS changed and the TTF decreased even at the high-dose levels for 70 kVp protocol compared to 120 kVp protocol. Our results indicated that the pre-reconstruction process is performed in low tube voltage CT for large objects even for the FBP reconstruction and has an effect on the image quality.


  • Patient dose reduction for a localizer radiograph with an additional tin filter in chest–abdomen–pelvis, spine, and head computed tomography examinations

    by Masaki Takemitsu, Kazuki Takegami, Shohei Kudomi, Kaito Kawanami

    This study aimed to evaluate the dose reduction potential of adding a tin filter to localizer radiographs (LR) on computed tomography (CT) examinations in both phantom and clinical studies. LRs were performed using combinations of 120 kVp and 20 mA (120/20), 100 kVp with a tin filter, and 50 mA or 20 mA (Sn100/50, Sn100/20). For the phantom experiment, entrance surface doses (ESD) of the LRs were evaluated for each protocol using an anthropomorphic phantom. This retrospective clinical study included 700 patients (300 for chest–pelvis, 200 for spine, and 200 for head CTs). The volume CT dose indices (CTDIvols) of the main CT scans were recorded and placed into one of three groups based on body mass index (BMI): underweight, normal-weight, and overweight, to evaluate the effect of LR acquisition conditions on the performance of the automatic tube current modulation technique of subsequent CT scans. The ESDs of all LRs with the Sn100/50 protocol were 0.03 mGy, a decrease of more than 80% compared to those of the 120/20 protocol. Moreover, the Sn100/20 protocol reduced ESD to 0.02 mGy. In chest–pelvis CT, there were no significant differences in the CTDIvol between with and without a tin filter for each BMI group. However, the lateral LRs with the tin filter on the spine CT slightly reduced the CTDIvol in normal-weight and overweight patients. Although there is room to optimize the acquisition conditions for larger patients, an additional tin filter for LR is a useful means to efficiently reduce ESDs.


  • Open Access

    Fundamental Study of nanoDot OSL Dosimeters for Entrance Skin Dose Measurement in Diagnostic X-ray Examinations

    by Tohru Okazaki, Hiroaki Hayashi, Kazuki Takegami, Hiroki Okino, Natsumi Kimoto, Itsumi Maehata, Ikuo Kobayashi

    FS (E): The number of energy E photon in the source material irradiation