MTMasaki Takemitsu

Masaki Takemitsu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Masaki Takemitsu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Improvement of the Visualization of the Adamkiewicz Artery Using a Virtual Non-Electrocardiogram-Gated Reconstruction in Electrocardiogram-Gated Computed Tomography Angiography for Aortic Diseases

    by Masaki Takemitsu, Shohei Kudomi, Kazuki Takegami, Takuya Uehara, Yu Teranaka, Masahiro Tanabe, Kenichiro Ihara, Katsuyoshi Ito

    Objective: Retrospective electrocardiogram (ECG)-gated CT angiography of the whole aorta is one of the most reasonable acquisition methods for simultaneously evaluating the aorta, coronary arteries, and the Adamkiewicz artery in the preoperative evaluation of aortic diseases. However, in retrospective ECG-gated reconstruction (ECG recon) of the Adamkiewicz artery, only a portion of the acquired data per heartbeat is used for image reconstruction. Therefore, we propose a virtual non-ECG-gated reconstruction (VNECG recon) for the Adamkiewicz artery by editing the ECG, which utilizes all acquired data. The purpose of this study is to evaluate the visualization of the Adamkiewicz artery using the VNECG recon. Methods: Fifty-three cases were analyzed using retrospective ECG-gated CT of the whole aorta from April 2023 to April 2024. We measured the signal-to-noise ratio (SNR) of the aorta and the contrast-to-noise ratio (CNR) of the anterior spinal artery relative to the spinal cord for both ECG recon and VNECG recon. The visualization scores of the Adamkiewicz artery were evaluated by 2 radiologists on a 4-point scale. Results: The SNR and CNR were improved with VNECG recon compared with those of ECG recon ( P P P =0.010, respectively). Conclusions: The visualization of the Adamkiewicz artery was improved by using a VNECG recon method, which avoided discarding any acquired data during the retrospective ECG-gated CT acquisition.

  • Standardization of image quality in dynamic chest radiography: a determination procedure of individualized exposure settings based on the data from plain chest radiography

    by Hiroaki Tsutsumi, Kazuki Takegami, Taiga Miura, Masaki Takemitsu, Ayumi Takegami, Shohei Kudomi, Sono Kanoya, Tsunahiko Hirano, Kazuto Matsunaga

    In plain chest radiography (CXR), automatic exposure control (AEC) is generally used to standardize image quality. In contrast, dynamic chest radiography (DCR) systems preliminarily require manual setting of tube current–time products (mAs value). Body mass index (BMI) of patients is one of the indexes to determine the mAs value; however, standardization is limited because the anatomical differences are not considered. In this study, for further standardization, we propose a practical procedure to determine the individual mAs value of DCR using data obtained from CXR. To evaluate its effectiveness, we retrospectively analyzed 97 patients who underwent both CXR and DCR on the same day. DCR was performed in the following procedures: (1) obtain the relationship between the mAs value and the exposure indicator (S value, Konica Minolta, Inc.) obtained in CXR acquisition, (2) calculate the mAs value of DCR for the target S value of 2500, and (3) record the S value in DCR. The tube voltages for CXR and DCR were set to 120 kV and 100 kV with a copper filter, respectively. The differences in exposure doses were corrected by measuring the air kerma using a CdTe detector. As a result, the S values of CXR and DCR were 133 ± 13 (Coefficient of Variation (CV) = 9.9%) and 2629 ± 207 (CV = 7.9%), respectively, which were not dependent on the patient size based on evaluating the S values of five classified BMI groups. In conclusion, our proposed procedure enables standardization of the image quality in DCR by optimizing the patient-specific exposure conditions.


  • The effect of a pre-reconstruction process in a filtered back projection reconstruction on an image quality of a low tube voltage computed tomography

    by Masaki Takemitsu, Shohei Kudomi, Kazuki Takegami, Takuya Uehara

    This study aims to evaluate the effect of pre-reconstruction process for low tube voltage computed tomography (CT) on image quality of filtered back projection (FBP) reconstruction. Small and large quality assurance water phantoms (19 and 33 cm diameter) were scanned on a third-generation dual-source CT with 70 kVp and 120 kVp at various dose levels. Image quality was assessed in terms of the noise power spectrum (NPS) and task-based transfer function (TTF). NPSs and TTFs in the small phantom were comparable between 70 and 120 kVp protocols. In the large phantom, the curves of the NPS changed and the TTF decreased even at the high-dose levels for 70 kVp protocol compared to 120 kVp protocol. Our results indicated that the pre-reconstruction process is performed in low tube voltage CT for large objects even for the FBP reconstruction and has an effect on the image quality.


  • Patient dose reduction for a localizer radiograph with an additional tin filter in chest–abdomen–pelvis, spine, and head computed tomography examinations

    by Masaki Takemitsu, Kazuki Takegami, Shohei Kudomi, Kaito Kawanami

    This study aimed to evaluate the dose reduction potential of adding a tin filter to localizer radiographs (LR) on computed tomography (CT) examinations in both phantom and clinical studies. LRs were performed using combinations of 120 kVp and 20 mA (120/20), 100 kVp with a tin filter, and 50 mA or 20 mA (Sn100/50, Sn100/20). For the phantom experiment, entrance surface doses (ESD) of the LRs were evaluated for each protocol using an anthropomorphic phantom. This retrospective clinical study included 700 patients (300 for chest–pelvis, 200 for spine, and 200 for head CTs). The volume CT dose indices (CTDIvols) of the main CT scans were recorded and placed into one of three groups based on body mass index (BMI): underweight, normal-weight, and overweight, to evaluate the effect of LR acquisition conditions on the performance of the automatic tube current modulation technique of subsequent CT scans. The ESDs of all LRs with the Sn100/50 protocol were 0.03 mGy, a decrease of more than 80% compared to those of the 120/20 protocol. Moreover, the Sn100/20 protocol reduced ESD to 0.02 mGy. In chest–pelvis CT, there were no significant differences in the CTDIvol between with and without a tin filter for each BMI group. However, the lateral LRs with the tin filter on the spine CT slightly reduced the CTDIvol in normal-weight and overweight patients. Although there is room to optimize the acquisition conditions for larger patients, an additional tin filter for LR is a useful means to efficiently reduce ESDs.