  • Standardization of image quality in dynamic chest radiography: a determination procedure of individualized exposure settings based on the data from plain chest radiography

    by Hiroaki Tsutsumi, Kazuki Takegami, Taiga Miura, Masaki Takemitsu, Ayumi Takegami, Shohei Kudomi, Sono Kanoya, Tsunahiko Hirano, Kazuto Matsunaga

    In plain chest radiography (CXR), automatic exposure control (AEC) is generally used to standardize image quality. In contrast, dynamic chest radiography (DCR) systems preliminarily require manual setting of tube current–time products (mAs value). Body mass index (BMI) of patients is one of the indexes to determine the mAs value; however, standardization is limited because the anatomical differences are not considered. In this study, for further standardization, we propose a practical procedure to determine the individual mAs value of DCR using data obtained from CXR. To evaluate its effectiveness, we retrospectively analyzed 97 patients who underwent both CXR and DCR on the same day. DCR was performed in the following procedures: (1) obtain the relationship between the mAs value and the exposure indicator (S value, Konica Minolta, Inc.) obtained in CXR acquisition, (2) calculate the mAs value of DCR for the target S value of 2500, and (3) record the S value in DCR. The tube voltages for CXR and DCR were set to 120 kV and 100 kV with a copper filter, respectively. The differences in exposure doses were corrected by measuring the air kerma using a CdTe detector. As a result, the S values of CXR and DCR were 133 ± 13 (Coefficient of Variation (CV) = 9.9%) and 2629 ± 207 (CV = 7.9%), respectively, which were not dependent on the patient size based on evaluating the S values of five classified BMI groups. In conclusion, our proposed procedure enables standardization of the image quality in DCR by optimizing the patient-specific exposure conditions.


  • Evaluation of femoral bone mineral density in patients with hip osteoarthritis using material density image in dual-energy computed tomography

    by Takuya Tani, Hiroki Mitsuzono, Kazuhiro Sadasue, Yuma Tsubaki, Osamu Jouno, Kojiro Nishijima, Shohei Kudomi

    Bone mineral density (BMD) around the implant may decrease post-total hip arthroplasty (THA), and it is important to evaluate changes in BMD pre- and post-THA. Dual-energy X-ray absorptiometry (DXA) is commonly used to evaluate BMD. However, in patients with hip osteoarthritis (OA), BMD obtained from DXA may be affected by bone deformities. Dual-energy computed tomography (DECT) can be used to produce material density image (MDI) that provide the material density values for arbitrary materials. This study aimed to determine the clinical utility of BMD assessment using DECT in patients with OA. The subjects were 80 patients (136 femurs) who underwent DECT and DXA of the femur between January 2021 and September 2023 and were classified into groups with and without OA. Calcium-water (Ca/W) density images were used for MDI. Correlation coefficients between the material density values obtained from Ca/W density images and DXA-obtained BMD were determined at the femoral neck, greater trochanter, and shaft. The femoral material density values obtained from Ca/W density images positively correlated with the DXA-obtained BMD. The correlation coefficients were 0.803 for the femoral neck, 0.762 for the femoral greater trochanter, and 0.598 for the femoral shaft in the group without OA, and 0.629 for the femoral neck, 0.825 for the femoral greater trochanter, and 0.634 for the femoral shaft in the group with OA. Our current study demonstrates that the density values obtained from the Ca/W density image suggest that it could serve as an indicator of femoral BMD.

  • The effect of a pre-reconstruction process in a filtered back projection reconstruction on an image quality of a low tube voltage computed tomography

    by Masaki Takemitsu, Shohei Kudomi, Kazuki Takegami, Takuya Uehara

    This study aims to evaluate the effect of pre-reconstruction process for low tube voltage computed tomography (CT) on image quality of filtered back projection (FBP) reconstruction. Small and large quality assurance water phantoms (19 and 33 cm diameter) were scanned on a third-generation dual-source CT with 70 kVp and 120 kVp at various dose levels. Image quality was assessed in terms of the noise power spectrum (NPS) and task-based transfer function (TTF). NPSs and TTFs in the small phantom were comparable between 70 and 120 kVp protocols. In the large phantom, the curves of the NPS changed and the TTF decreased even at the high-dose levels for 70 kVp protocol compared to 120 kVp protocol. Our results indicated that the pre-reconstruction process is performed in low tube voltage CT for large objects even for the FBP reconstruction and has an effect on the image quality.


  • Patient dose reduction for a localizer radiograph with an additional tin filter in chest–abdomen–pelvis, spine, and head computed tomography examinations

    by Masaki Takemitsu, Kazuki Takegami, Shohei Kudomi, Kaito Kawanami

    This study aimed to evaluate the dose reduction potential of adding a tin filter to localizer radiographs (LR) on computed tomography (CT) examinations in both phantom and clinical studies. LRs were performed using combinations of 120 kVp and 20 mA (120/20), 100 kVp with a tin filter, and 50 mA or 20 mA (Sn100/50, Sn100/20). For the phantom experiment, entrance surface doses (ESD) of the LRs were evaluated for each protocol using an anthropomorphic phantom. This retrospective clinical study included 700 patients (300 for chest–pelvis, 200 for spine, and 200 for head CTs). The volume CT dose indices (CTDIvols) of the main CT scans were recorded and placed into one of three groups based on body mass index (BMI): underweight, normal-weight, and overweight, to evaluate the effect of LR acquisition conditions on the performance of the automatic tube current modulation technique of subsequent CT scans. The ESDs of all LRs with the Sn100/50 protocol were 0.03 mGy, a decrease of more than 80% compared to those of the 120/20 protocol. Moreover, the Sn100/20 protocol reduced ESD to 0.02 mGy. In chest–pelvis CT, there were no significant differences in the CTDIvol between with and without a tin filter for each BMI group. However, the lateral LRs with the tin filter on the spine CT slightly reduced the CTDIvol in normal-weight and overweight patients. Although there is room to optimize the acquisition conditions for larger patients, an additional tin filter for LR is a useful means to efficiently reduce ESDs.


  • Biological fingerprint for patient verification using trunk scout views at various scan ranges in computed tomography

    by Yasuyuki Ueda, Junji Morishita, Shohei Kudomi

    Immediate verification of whether a patient being examined is correct is desirable, even if the scan ranges change during different examinations for the same patient. This study proposes an advanced biological fingerprint technique for the rapid and reliable verification of various scan ranges in computed tomography (CT) scans of the torso of the same patient. The method comprises the following steps: geometric correction of different scans, local feature extraction, mismatch elimination, and similarity evaluation. The geometric magnification correction was aligned at the scanner table height in the first two steps, and the local maxima were calculated as the local features. In the third step, local features from the follow-up scout image are matched to those in the corresponding baseline scout image via template matching and outlier elimination via a robust estimator. We evaluated the correspondence rate based on the inlier ratio between corresponding scout images. The ratio of inliers between the baseline and follow-up scout images was assessed as the similarity score. The clinical dataset, including chest, abdomen–pelvis, and chest–abdomen–pelvis scans, included 600 patients (372 men, 68 ± 12 years) who underwent two routine torso CT examinations. The highest area under the receiver operating characteristic curve (AUC) was 0.996, which was sufficient for patient verification. Moreover, the verification results were comparable to the conventional method, which uses scout images in the same scan range. Patient identity verification was achieved before the main scan, even in follow-up torso CT, under different scan ranges.


  • Open Access

    Hounsfield Unit Value of Interpeduncular Cistern Hematomas Can Predict Symptomatic Vasospasm

    by Hideyuki Ishihara, Fumiaki Oka, Reo Kawano, Mizuya Shinoyama, Takuma Nishimoto, Shohei Kudomi, Michiyasu Suzuki

    Background and Purpose—: Symptomatic vasospasm is an important factor that affects the outcomes of aneurysmal subarachnoid hemorrhage. Subarachnoid blood volume can predict symptomatic vasospasm, and we postulated that the blood clot density would also be an important factor involved in such events. The present study aimed to determine the relationship between the incidence of symptomatic vasospasm and the Hounsfield unit (HU) value of the interpeduncular cistern that reflects the density of hematomas. Methods—: Data from 323 patients admitted and treated at a single center between 2008 and 2017 within 24 hours of subarachnoid hemorrhage onset were retrospectively analyzed. Initial HU values of the interpeduncular cistern were measured using CT, then correlations with the incidence of symptomatic vasospasm and HU values as well as other variables were assessed. Results—: Symptomatic vasospasm developed in 54 (16.7%) of the 323 patients. The incidence of symptomatic vasospasm was low (1.8%, 2/166) for HU 50 to ≤60, and 45.3%, 29/64 for HU >60). The odds ratio for symptomatic vasospasm was 2.0 (95% CI, 1.6–2.4) per 5 HU increase. Symptomatic vasospasm correlated significantly with intraventricular hemorrhage ( P =0.05) and with intracerebral hematoma ( P =0.046) but even more significantly with the HU value of the interpeduncular cistern ( P <0.0001). Conclusions—: The HU value of the interpeduncular cistern on initial CT is an accurate and reliable predictor of symptomatic vasospasm.


  • Automatic ROI construction for analyzing time–signal intensity curve in dynamic contrast-enhanced MR imaging of the breast

    by Koya Fujimoto, Yasuyuki Ueda, Shohei Kudomi, Teppei Yonezawa, Yuki Fujimoto, Katsuhiko Ueda

    Our purpose in this study was to construct a 3-dimensional (3D) region of interest (ROI) for analyzing the time–signal intensity curve (TIC) semi-automatically in dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging of the breast. DCE-MR breast imaging datasets were acquired by a 3.0-Tesla MR system with the use of a 3D fast gradient echo sequence. The essential idea in the new method was to analyze each pixel and to construct an ROI made up of pixels with similar TICs. First, an analyst selected a starting point in the contrast media-enhanced tumor. Second, we calculated Pearson’s correlation coefficients (CCs) between the TIC in the starting coordinate selected by the analyst and the TIC in the other coordinates. Third, ROI pixels were selected if their CC threshold satisfied a level of coefficient variation of the ROI determined by prior research performed in our institution. We made a retrospective review of patients who underwent breast DCE-MR examination for pre-operative diagnosis. To confirm the feasibility of the resulting 3D-ROI from TIC analysis, we compared Fischer’s score obtained from 3D-ROI by applying a new method to a score obtained from a manually selected 2-dimensional (2D) ROI which was used during routine clinical examination. The Fischer’s scores obtained from both the automatically selected 3D-ROI and the manually selected 2D-ROI showed almost equivalent results. Thus, we considered that the new method was comparable to the conventional method. Furthermore, the new method has the potential to be used for evaluation of the extent of tumors.


  • Dual-energy perfusion CT of non-diseased lung segments using dual-source CT: correlation with perfusion SPECT

    by Yoshie Kunihiro, Munemasa Okada, Naofumi Matsunaga, Yuichi Sano, Shohei Kudomi, Kazuyoshi Suga, Shoji Kido


  • Correction of liver displacement due to irregular respiration for SPECT images obtained using a multiple short-time acquisition with breath-holding technique

    by Yasuyuki Ueda, Shohei Kudomi, Masahiro Koike, Yona Oishi, Hideyuki Iwanaga, Katsuhiko Ueda

    Recently, a new method for acquiring single photon emission computed tomography (SPECT) data during breath-holding with a high-speed rotation (HSR-SPECT) technique was applied to hepatic-function scintigraphy. This technique can suppress motion artifact caused by respiration. However, it is challenging to apply this technique to patients with respiratory problems. Our purpose in this study was to analyze projection data and correct liver displacement due to irregular respiration during technetium-99m-diethylenetriaminepentaacetic acid galactosyl human serum albumin (99mTc-GSA) liver SPECT scans. We calculated cross-correlation functions (CCFs) for both intra- and inter-projections to correct irregular projections by shifting them in the longitudinal direction enough to maximize the CCFs. We integrated all of the shifted projections and created a synthesis projection which was used to reconstruct SPECT images. To confirm the effectiveness of our method, we did both a phantom study and a clinical retrospective review. In the phantom study, blurring artifacts due to displacement were reduced using our method. Post-processing using our method showed improvements in the normalized mean square error values ranging from 0.18 to 0.06. Furthermore, our method showed no disadvantage or miss-correction if we applied our method to data without displacement. In the clinical review, our method improved the image clarity for patients who could not repeat consistent respiration. In both the phantom simulation and the clinical application, the results showed the usefulness of our method. The efficiency of our method has the potential to reduce the displacement problem caused by respiration and provides excellent matching SPECT/CT fusion images.


  • Evaluation of the spatial resolution of multiplanar reconstruction images

    by Shohei Kudomi, Katsuhiko Ueda, Yasuyuki Ueda, Masateru Kawakubo, Taizo Sanada

    We present a simple method for evaluating the spatial resolution of multi-slice computed tomography (MSCT) multiplanar reconstruction images (MPRs). We scanned a bead phantom to obtain the three-dimensional point spread function (PSF), and bead-centric MPRs were generated. The modulation transfer function (MTF) was calculated from the MPRs via a two-dimensional Fourier transform (2DFFT) of the PSF. The results showed that, when MPRs were reconstructed using axial images less than or equal to a nominal 1.0-mm slice-width with a standard kernel for the abdomen, the MTF in the longitudinal direction (z-direction) was superior to that in the in-plane (x–y plane) direction. It was also found that the arbitrary-angle MTFs of MPRs were between the MTFs of the in-plane and longitudinal directions. It was confirmed that this method can be used to evaluate MPR spatial resolution.