Modulation factors calculated with an EPID‐derived MLC fluence model to streamline IMRT/VMAT second checks
Authors:
Open Access
- 8 November 2013
- journal article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 14 (6) , 62-81
Abstract
This work outlines the development of a robust method of calculating modulation factors used for the independent verification of MUs for IMRT and VMAT treatments, to replace onerous ion chamber measurements. Two-dimensional fluence maps were calculated for dynamic MLC fields that include MLC interleaf leakage, transmission, and tongue-and-groove effects, as characterized from EPID-acquired images. Monte Carlo-generated dose kernels were then used to calculate doses for a modulated field and that field with the modulation removed at a depth specific to the calculation point in the patient using in-house written software, Mod_Calc. The ratio of these two doses was taken to calculate modulation factors. Comparison between Mod_Calc calculation and ion chamber measurement of modulation factors for 121 IMRT fields yielded excellent agreement, where the mean difference between the two was . This validated use of Mod_Calc clinically. Analysis of 5,271 dynamic fields from clinical use of Mod_Calc gave a mean difference of between Mod_Calc and Eclipse-generated factors. In addition, 99.3% and 96.5% fields pass 5% and 2% criteria, respectively, for agreement between these two predictions. The development and use of Mod_Calc at our clinic has considerably streamlined our QA process for IMRT and RapidArc fields, compared to our previous method based on ion chamber measurements. As a result, it has made it feasible to maintain our established and trusted current in-house method of MU verification, without resorting to commercial software alternatives. PACS numbers: 87.55.km, 87.55.Qr, 87.55.kd, 87.57.uq
Keywords
This publication has 28 references indexed in Scilit:
- Dosimetry tools and techniques for IMRTMedical Physics, 2011
- Verification of monitor unit calculations for non‐IMRT clinical radiotherapy: Report of AAPM Task Group 114Medical Physics, 2010
- A separated primary and scatter model for independent dose calculation of intensity modulated radiotherapyRadiotherapy and Oncology, 2006
- Absolute dose calculations for Monte Carlo simulations of radiotherapy beamsPhysics in Medicine & Biology, 2005
- A simple theoretical verification of monitor unit calculation for intensity modulated beams using dynamic mini-multileaf collimationRadiotherapy and Oncology, 2004
- Independent dosimetric calculation with inclusion of head scatter and MLC transmission for IMRTMedical Physics, 2003
- Independent monitor unit calculation for intensity modulated radiotherapy using the MIMiC multileaf collimatorMedical Physics, 2002
- Point dose calculations using an analytical pencil beam kernel for IMRT plan checkingPhysics in Medicine & Biology, 2001
- A monitor unit verification calculation in intensity modulated radiotherapy as a dosimetry quality assuranceMedical Physics, 2000
- Computer verification of fluence map for intensity modulated radiation therapyMedical Physics, 2000