SSStephen Steciw

Stephen Steciw

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stephen Steciw has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Bg Gino Fallone

    University of Alberta

    2 shared publications
  • Andrei Ghila

    Department of Oncology Medical Physics Division University of Alberta 11560 University Avenue Edmonton Alberta T6G 1Z2 Canada

    1 shared publication
  • B. Warkentin

    Department of Medical Physics, Cross Cancer Institute, Alberta T6G 1Z2, Canada

    1 shared publication
  • Brad Warkentin

    Department of Medical Physics Cross Cancer Institute Edmonton AB Canada

    1 shared publication
  • Devin Baillie

    Medical Physics Division, Department of Oncology, University of Alberta, 11560 University Avenue, Edmonton, Alberta, T6G 1Z2, Canada

    1 shared publication
  • S. Rathee

    Department of Medical Physics, Cross Cancer Institute, 11560 University Avenue, Alberta T6G 1Z2, Canada and Department of Oncology, Medical Physics Division, University of Alberta, 11560 University Avenue, Edmonton, Alberta T6G 1Z2, Canada

    1 shared publication

Latest Publications

  • A convolution-superposition fluence model for the Siemens HD120 multi leaf collimator with application to a 3D VMAT dose engine

    by Stephen Steciw

    Purpose. To construct a fast-calculating fluence modelfor the Siemens HD120 multi leaf collimator (MLC) using convolution-superposition techniques, and to develop a 3D VMAT dose engine using this fluence model. This work offers analternative to time-consuming open-source Monte Carlo simulations for thosedeveloping in-house dose-calculating software for research or clinical needs.Methods. EPID-acquired images of sweeping-window and sweeping-checker field profiles were used to commission transmission, 2 Dinterleaf leakage, and tongue-and-groove maps specific to the HD120 MLC. These maps, along with a 2D head-scattermodel were incorporated into a convolution-superposition algorithm to provide a fluence model for the HD120 MLC. This fluence model was used to develop a 3D VMAT dose engine, where 3D pre-computed 6MV dose kernels (EGSnrc) and a 3D fluence curvature-correction map were incorporatedto calculate 3D VMAT doses in a 22 cm diameter cylindrical phantom. Four VMAT patient plans witha large range of PTV sizes (36 cc to 604 cc) were chosen to test the fluence model and dose engine. Results. Excellent agreement was observed between the simulated commissioning fields and measured EPID-responses. 2D 2%/2 mm gamma analysis yielded a 98.9% pass rate for 1 cm, 2 cm, and 4 cm sweeping-window fields. 2D 2%/2mm gamma analysis for outer/inner MLC leaves yielded 89.1%/77.0% and 95.2%/91.1% pass rates from 1 cm and 2 cm sweeping-checker fields. Mean 3%/3 mm gamma analysis showed excellent agreement between our dose engine and Eclipse (Acuros) regardless of PTV size: 98.7% pass rate, with 95.1% pass rate in the high-dose volume. Fluence calculation times were13.6 seconds per dynamic MLC field and 1.4 minutes/arc for 3D VMAT dose on a standard PC. Conclusions. A fast-calculating convolution-superposition fluence model has been commissioned for the Siemens HD120 MLC and incorporatedinto a 3D VMAT dose engine. This work can be used to facilitate the development of fast in-house dose-calculating software.

  • Open Access

    Experimental verification of EGSnrc Monte Carlo calculated depth doses within a realistic parallel magnetic field in a polystyrene phantom

    by Andrei Ghila, Stephen Steciw, B. Gino Fallone, Satyapal Rathee

    Integrating a linac with a magnetic resonance imager (MRI) will revolutionize the accuracy of external beam radiation treatments. Irradiating in the presence of a strong magnetic field, however, will modify the dose distribution. These dose modifications have been investigated previously, mainly using Monte Carlo simulations. The purpose of this work is to experimentally verify the use of the EGSnrc Monte Carlo (MC) package for calculating percent depth doses (PDDs) in a homogeneous phantom, in the presence of a realistic parallel magnetic field. Two cylindrical electromagnets were used to produce a 0.207 T magnetic field parallel to the central axis of a 6 MV photon beam from a clinical linac. The magnetic field was measured at discrete points along orthogonal axes, and these measurements were used to validate a full 3D magnetic field map generated using COMSOL Multiphysics. Using a small parallel plate ion chamber, the depth dose was measured in a polystyrene phantom placed inside the electromagnet bore at two separate locations: phantom top surface coinciding with top of bore, and phantom top surface coinciding with center of bore. BEAMnrc MC was used to model the linac head which was benchmarked against the linac's commissioning measurements. The depth dose in polystyrene was simulated using DOSXYZnrc MC. For the magnetic field case, the DOSXYZnrc code was slightly modified to implement the previously calculated 3D magnetic field map to be used in the standard electromagnetic macros. The calculated magnetic field matched the measurements within 2% of the maximum central field (0.207 T) with most points within the experimental uncertainty (1.5%). For the MC linac head model, over 93% of all simulated points passed the 2%, 2 mm γ acceptance criterion, when comparing measured and simulated lateral beam and depth dose profiles. The parallel magnetic field caused a surface dose increase, compared to the no magnetic field case, due to the Lorentz force confining contaminant electrons within the beam. The surface dose increase was measured to be approximately 10% (relative to no field Dmax) when the phantom surface coincided with the top of the electromagnet's bore. This effect was enhanced by moving the phantom surface to the center of the magnet's bore in relatively high magnetic field (> 0.13 T). The surface dose for this setup increased by 30% and the entire buildup region was affected. When the dimensions and composition of the ion chamber air cavity and entrance window were included, EGSnrc was able to accurately simulate these dose increases, both at the surface and in the buildup region. All the simulated points were within 1% of the measurements for both setups. The ferromagnetic linac head was determined to have a negligible effect on the final PDD comparison. Irradiating in the presence of a parallel magnetic field causes measurable surface and buildup depth dose increases. We have experimentally verified that the EGSnrc Monte Carlo package is able to accurately calculate the PDDs with these surface and buildup dose modifications in a homogeneous phantom.


  • Design and simulation of a short, variable-energy 4 to 10 MV S-band linear accelerator waveguide

    by Devin Baillie, B. Gino Fallone, Stephen Steciw

    To modify a previously-designed, short, 10 MV linac waveguide so that it can produce any energy from 4 to 10 MV. The modified waveguide is designed to be a drop-in replacement for the 6MV waveguide used in the author's current linear accelerator-magnetic resonance imager (Linac-MR). Using our group's previously designed short 10 MV linac as a starting point, the port was moved to the fourth cavity, the shift to the first coupling cavity was removed and a tuning cylinder added to the first coupling cavity. Each cavity was retuned using finite element method (FEM) simulations to resonate at the desired frequency. FEM simulations were used to determine the RF field distributions for various tuning cylinder depths, and electron trajectories were computed using a particle-in-cell model to determine the required RF power level and tuning cylinder depth to produce electron energy distributions for 4, 6, 8, and 10 MV photon beams. Monte Carlo simulations were then used to compare the depth dose profiles with those produced by published electron beam characteristics for Varian linacs. For each desired photon energy, the electron beam energy was within 0.5% of the target mean energy, the depth of maximum dose was within 1.5 mm of that produced by the Varian linac, and the ratio of dose at 10 cm depth to 20 cm depth was within 1%. A new 27.5 cm linear accelerator waveguide design capable of producing any photon energy between 4 and 10 MV has been simulated, however coupling port design and the implications of increased electron beam current at 10 MV remain to be investigated. For the specific cases of 4, 6, and 10 MV, this linac produces depth dose profiles similar to those produced by published spectra for Varian linacs.


  • Open Access

    Modulation factors calculated with an EPID‐derived MLC fluence model to streamline IMRT/VMAT second checks

    by Stephen Steciw, Satyapal Rathee, Brad Warkentin

    This work outlines the development of a robust method of calculating modulation factors used for the independent verification of MUs for IMRT and VMAT treatments, to replace onerous ion chamber measurements. Two-dimensional fluence maps were calculated for dynamic MLC fields that include MLC interleaf leakage, transmission, and tongue-and-groove effects, as characterized from EPID-acquired images. Monte Carlo-generated dose kernels were then used to calculate doses for a modulated field and that field with the modulation removed at a depth specific to the calculation point in the patient using in-house written software, Mod_Calc. The ratio of these two doses was taken to calculate modulation factors. Comparison between Mod_Calc calculation and ion chamber measurement of modulation factors for 121 IMRT fields yielded excellent agreement, where the mean difference between the two was ?0.3%1.2% . This validated use of Mod_Calc clinically. Analysis of 5,271 dynamic fields from clinical use of Mod_Calc gave a mean difference of 0.3%1.0% between Mod_Calc and Eclipse-generated factors. In addition, 99.3% and 96.5% fields pass 5% and 2% criteria, respectively, for agreement between these two predictions. The development and use of Mod_Calc at our clinic has considerably streamlined our QA process for IMRT and RapidArc fields, compared to our previous method based on ion chamber measurements. As a result, it has made it feasible to maintain our established and trusted current in-house method of MU verification, without resorting to commercial software alternatives. PACS numbers: 87.55.km, 87.55.Qr, 87.55.kd, 87.57.uq