Comparison of Eight Different Digital Chest Radiography Systems: Variation in Detection of Simulated Chest Disease
- 1 August 2005
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 185 (2) , 339-346
Abstract
OBJECTIVE. In a short period, a variety of technically different digital radiography chest systems have become available for clinical use. Our purpose was to assess the diagnostic performance of eight different digital radiography chest systems for detection of simulated chest disease under clinical conditions.MATERIALS AND METHODS. Assessed were four different flat-panel detector systems, two different charge-coupled device systems, one selenium-coated drum, and one storage phosphor system. For each system, 10 chest images of an anthropomorphic chest phantom were obtained. Each image contained one to 12 simulated chest lesions. Eight radiologists performed soft-copy interpretations. Entrance dose was measured and effective dose calculated. A semiparametric logistic regression model was used for statistical analysis.RESULTS. Statistically significant differences were found in the diagnostic performance of the eight digital chest systems (p = 0.01). Best performance was observed with the charge-coupled dev...Keywords
This publication has 30 references indexed in Scilit:
- Digital Slot-Scan Charge-coupled Device Radiography versus AMBER and Bucky Screen-Film Radiography for Detection of Simulated Nodules and Interstitial Disease in a Chest PhantomRadiology, 2004
- Digital Radiography of the Chest: Detector Techniques and Performance ParametersJournal of Thoracic Imaging, 2003
- Comparing Image Quality of Flat-Panel Chest Radiography with Storage Phosphor Radiography and Film-Screen RadiographyAmerican Journal of Roentgenology, 2003
- Digital Chest ImagingInvestigative Radiology, 2002
- Selenium-Based Digital Radiography Versus High-Resolution Storage Phosphor Radiography in the Detection of Solitary Pulmonary Nodules Without CalcificationAmerican Journal of Roentgenology, 2001
- Digital Chest Radiography with a Selenium-Based Flat-Panel Detector Versus a Storage Phosphor SystemAmerican Journal of Roentgenology, 2000
- Principles of Digital Radiography with Large-Area, Electronically Readable Detectors: A Review of the BasicsRadiology, 1999
- System considerations in CCD‐based x‐ray imaging for digital chest radiography and digital mammographyMedical Physics, 1997
- Selenium radiography versus storage phosphor and conventional radiography in the detection of simulated chest lesions.Radiology, 1996
- Image quality of a digital chest radiography system based on a selenium detectorMedical Physics, 1994