Effects of neutral gas pressure on calibration parameters of resistive bolometer sensors in fusion devices
Open Access
- 1 July 2024
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Abstract
Ambient pressure may influence the thermal path between the absorber and heat sink of resistive bolometers and thus impact the calibration parameters. This effect is investigated for metal resistive bolometer sensors as used in bolometer diagnostics on fusion experiments. Measurements in the test facility IBOVAC indicate that pressure has no effect up to 10−3 mbar. However, a significant change in the cooling time constant is observed for pressures above 10−2 mbar, a reduction up to a factor of three at 1 mbar. The measurements performed in N2 and He atmospheres and simulations in H2 indicate no difference between the results from different gas species up to 10−3 mbar and less than 10 % up to 0.1 mbar. A model based on the thermal conductivity of the surrounding gas combined with the geometry of the sensor holder successfully demonstrates that the additional cooling path through the gas, which may vary between the measurement and reference absorbers, can explain the measurement results. Applying the model to the geometry of a sensor holder designed for port-mounted bolometer cameras in ITER led to design modifications that should help reduce the impact of high environmental pressures on the bolometer measurements. Similarly, it can be assumed that applying the model to the geometries and sensors of operating bolometer diagnostics can help correct the measurements and improve the understanding of plasma radiation in the case of high pressures at the location of bolometer sensors.Keywords
Funding Information
- Fusion for Energy (F4E-FPA-384-SG05)
This publication has 17 references indexed in Scilit:
- Calibration and thermal test results of prototype bolometer sensors for ITER fusion reactorReview of Scientific Instruments, 2023
- Bolometer sensor holder suitable for ITER-relevant conditionsFusion Engineering and Design, 2023
- Transient thermal conductivity in PECVD SiNx at high temperature: The thermal signature of an on-going irreversible modificationMaterialia, 2022
- Calibration parameter drift compensation of metal resistive bolometers operating in a thermal varying environmentFusion Engineering and Design, 2017
- Disruption mitigation by injection of small quantities of noble gas in ASDEX UpgradePlasma Physics and Controlled Fusion, 2016
- Millimetre wave attenuation of prototype diagnostic components for the ITER bolometersFusion Engineering and Design, 2015
- Derivation of bolometer equations relevant to operation in fusion experimentsReview of Scientific Instruments, 2002
- A low noise highly integrated bolometer array for absolute measurement of VUV and soft x radiationReview of Scientific Instruments, 1991
- Critical Analysis of Heat—Capacity Data and Evaluation of Thermodynamic Properties of Ruthenium, Rhodium, Palladium, Iridium, and Platinum from 0 to 300K. A Survey of the Literature Data on Osmium.Journal of Physical and Chemical Reference Data, 1974
- Thermal Conductivity of the ElementsJournal of Physical and Chemical Reference Data, 1972