Latest Publications

  • Open Access

    Neutral gas pressure gauges in magnetic confinement fusion: From ASDEX Upgrade/W7-X to ITER/SPARC and beyond (invited)

    by M. Griener, C. Drobny, G. Schlisio, H. Meister, E. Fox-Widdows, A. Zito, A. Glock, G. Birkenmeier, Asdex Upgrade Team, W7-X Team, et al.

    The neutral gas pressure at the plasma boundary is crucial for validating physics-based plasma models and for real-time fueling and exhaust control in magnetic confinement fusion devices. Specialized linear hot cathode ionization gauges, the so-called ASDEX-type gauges or manometers, provide absolute neutral density measurements with kilohertz temporal resolution in strong magnetic fields and the harsh in-vessel reactor environment. This paper summarizes the learnings and open questions encountered during the operation of pressure gauges at ASDEX Upgrade (AUG) and Wendelstein 7-X (W7-X), as well as our laboratory-led development of ITER manometers, with ongoing deployment on SPARC. We address the operation principle and engineering of these specialized pressure gauges and outline the development history of various sensor head types. In doing so, the focus lies on different electron-emitter concepts, including thoriated tungsten wires used at AUG and indirectly heated emitters, such as LaB6 at W7-X and ZrC, which is foreseen for ITER and SPARC. We present the operation of pressure gauges with a comprehensive overview of the various measurement positions at AUG, W7-X, ITER, and SPARC. This paper concludes with ongoing model- and laboratory-driven developments aimed at ensuring the availability of real-time-capable pressure sensors for future commercial fusion reactors, where reliability, radiation hardness, and lifetime are of the utmost importance.

  • Open Access

    Operation of ITER Prototype Diagnostic Pressure Gauges at Exceptional Pressure Increases

    by H. Meister, C. Drobny, F. Mackel, P. Casas, M. Griener, J. Perez, P. Valente

  • Structural Analysis and Design Optimization of the ITER Upper Port-Mounted Bolometer Cameras

    by Nikola Jaksic, Zhongwei Wang, Hans Meister, Adam Pataki, Villarejo Miguel Ángel, Javier Rodríguez Casado

    The development of the bolometer camera structural design is especially challenging because of the extreme environmental conditions within the vacuum vessel (VV) during plasma operation. Reliable measurements have to be assured while being subjected to high neutron fluxes as well as plasma radiation resulting in temperatures of the components exceeding $200~^{\circ }$ C. In addition to the thermal loads, the bolometer camera housing is exposed to mechanical loads caused by electromagnetic (EM) forces during transient events of the plasma operation, called disruptions. Due to the fact that the surrounding structure of the diagnostic shield module (DSM) within the upper and equatorial ports was already determined in advance, extensive design adaptation of all bolometer cameras was required. Extensive numerical analyses were carried out with the aim of achieving structural stability of the camera main body on the one hand and thermal requirements on the camera and sensors on the other hand. In a multiphysics analysis loop, several cycles were performed, starting with the EM, followed by a thermomechanical and structural analysis. In addition, the seismic and gravity loads and load scenarios, like inductive and noninductive plasma radiation as well as fatigue cycles, need to be considered. This article gives an overview of such a comprehensive analysis on the example of bolometer cameras mounted in the upper port and presents the results achieved as well as the compromises taken.

  • Spurious radiated power signal following massive material injections in JET and the effect of neutral gas pressure on resistive bolometers

    by N. Schoonheere, C. Reux, H. Meister, P. Beyer, P. Carvalho, I. Coffey, K. Lawson, P. Puglia, U. Sheikh, Jet Contributors, et al.

    Massive material injections in the JET tokamak have been observed to substantially affect resistive bolometer measurements, resulting in a spurious radiated power signal proportional to the quantity injected and reaching up to 8 MW. These bolometers are calibrated and designed to operate in near vacuum but certain scenarios requiring large gas injections can push the neutral pressure past nominal values. This study demonstrates that the bolometry measurement can be affected at neutral pressures above 0.1 Pa following injections with standard gas valves, shattered pellet injections, and particularly massive gas injections. The power measurement of resistive bolometers is based on the temperature difference between a measurement sensor exposed to radiation and a shielded reference sensor. We employ a thermal conductivity model to demonstrate that the conduction through the gas and the distinct geometries between the sensors can affect their cooling efficiency. This additional cooling pathway, coupled with the Joule heating from the applied voltage causes the equilibrium temperatures of the sensors to diverge. Being the very basis of the measure, this temperature difference induces a signal that is erroneously interpreted as radiated power. Experiments show large discrepancies in the response to neutral pressure among bolometer channels, attributed to variations in channel physical parameters. Nonetheless, the modeled total radiated power reproduces the experimental measurements within an order of magnitude, affirming the sensitivity of resistive bolometers to neutral pressure and gas species.


  • Open Access

    Performance of ITER pressure gauges during deuterium operation in the large helical device

    by Uwe Wenzel, Gen Motojima, Felix Mackel, Alexey Arkhipov, Bartholomew Jagielski, Victoria Haak, Hans Meister, Mirko Marquardt, Ella Fox-Widdows

    During deuterium campaigns on the heliotron large helical device (LHD), ITER pressure gauges with different cathode materials were used to measure the neutral pressure in the sub-divertor region. Throughout these campaigns, it was observed that the performance of a LaB6 cathode was unsatisfactory during deuterium operation. Conversely, measurements taken with pressure gauges with a ZrC cathode performed well throughout the deuterium pulses. The ITER pressure gauge with the ZrC cathode could be operated with a very high electron current of 800 µA, thus improving the lower detection limit of the neutral pressure in LHD. With this design it was also possible to avoid jumps in the ion current within strong magnetic fields, improving the accuracy of the measurement from 15% uncertainty to 5%. These features allowed very precise neutral pressure measurements to be made in a fusion device with magnetic confinement. The problems with the lifetime of the ZrC cathode reported in Mackel et al (2023 Fusion Eng. Des. 189 113439) were not relevant here, as the total runtime in the magnetic field was about 60 h, less than the expected lifetime of the cathode of 350 h.


  • Open Access

    Effects of neutral gas pressure on calibration parameters of resistive bolometer sensors in fusion devices

    by H. Meister, S. Jahanbakhsh, D. Zhang, L.C. Ingesson, A. Pataki

    Ambient pressure may influence the thermal path between the absorber and heat sink of resistive bolometers and thus impact the calibration parameters. This effect is investigated for metal resistive bolometer sensors as used in bolometer diagnostics on fusion experiments. Measurements in the test facility IBOVAC indicate that pressure has no effect up to 10−3 mbar. However, a significant change in the cooling time constant is observed for pressures above 10−2 mbar, a reduction up to a factor of three at 1 mbar. The measurements performed in N2 and He atmospheres and simulations in H2 indicate no difference between the results from different gas species up to 10−3 mbar and less than 10 % up to 0.1 mbar. A model based on the thermal conductivity of the surrounding gas combined with the geometry of the sensor holder successfully demonstrates that the additional cooling path through the gas, which may vary between the measurement and reference absorbers, can explain the measurement results. Applying the model to the geometry of a sensor holder designed for port-mounted bolometer cameras in ITER led to design modifications that should help reduce the impact of high environmental pressures on the bolometer measurements. Similarly, it can be assumed that applying the model to the geometries and sensors of operating bolometer diagnostics can help correct the measurements and improve the understanding of plasma radiation in the case of high pressures at the location of bolometer sensors.


  • Open Access

    Verification of lifetime and mechanical load aspects for ITER diagnostic pressure gauges based on ZrC emitter

    by H. Meister, F. Mackel, P. Andrew, J. Perez, P. Valente, U. Walach

    Hot cathode ionization gauges will measure the neutral gas pressure in the vacuum vessel of ITER. Overall, 52 gauge heads based on the concept of the ASDEX pressure gauge but using novel ZrC emitters are located in the divertor, in equatorial ports and in pumping ducts. The initial lifetime tests of the novel gauge design have raised the concern that the pyrolytic graphite used to indirectly heat the ceramic ZrC emitter erodes too fast during operation. This effect might limit the lifetime of the gauges below the limits acceptable according to the inherent availability (ignoring operational delays) requirement of 99.8% for the diagnostic system over the lifetime of ITER. Long term operation tests have been performed using 0.1 mm thick W, Ir, and Mo foils as an interlayer between the pyrolytic graphite and the ZrC within a constant atmosphere of 20 Pa H2. The longest lifetime of 860 h has been achieved with the Ir foil. Subsequent vibration tests applying accelerations on a shaker with magnitudes typical for seismic and ITER disruption loads demonstrated that the emitter can survive such demanding loads even after far-progressed erosion of the pyrolytic graphite. Additional ON/OFF cycle tests demonstrated that the gauge is still fully operational. In combination with a revision and consolidation of the operational plan and the reliability, accessibility, maintainability, and inspectability (RAMI) analysis, ITER’s inherent availability requirement for the diagnostic system could be demonstrated successfully.


  • Open Access

    Optimizing ITER Bolometer Cameras in View of Internal Reflections and Crosstalk Between Channels

    by H. Meister, I. Kudashev, M. Brank, L. C. Ingesson

    Bolometer cameras in ITER (lat.: the way) are designed as pinhole and collimator cameras, optimizing the requirements from available physical space, constraints in design options and desired line-of-sight (LOS) distribution. While for both camera types of internal reflections can be significant and lead to an increase in the effective viewing cone, collimator cameras may also suffer from crosstalk of light between channels in case internal apertures are not optimized. The concepts and simulations employed to optimize bolometer collimator cameras are presented. They are based on geometrical considerations for choosing the number and distribution of internal apertures, using the desired viewing cones as input. In the second step, ray-tracing simulations based on the Raysect packages are applied to assess internal reflections as a function of wavelength in the range IR to X-rays for the chosen geometry as well as to assess the impact of choices for material and material finishings (e.g., roughness). Examples presented focus on port-mounted bolometer cameras. The results allow us to improve the geometrical description of bolometer cameras in the ITER database of synthetic diagnostics and thus support performance assessments and studies in the preparation of tomographic reconstructions of plasma radiation. For example, the calculated measurements for LOS assuming standard radiation distributions for ITER are presented.


  • Generic approach to assess the measuring performance of total-radiated power quantities by multi-channel resistive bolometer diagnostics on fusion experiments

    by L. C. Ingesson, A. Doblas, A. Gandhi, S. Jahanbakhsh, H. Meister

    On present-day magnetic-confinement fusion experiments, the performance of multi-channel bolometer diagnostics has typically evolved over time through experience with earlier versions of the diagnostic and experimental results obtained. For future large-scale fusion experiments and reactors, it is necessary to be able to predict the performance as a function of design decisions and constraints. A methodology has been developed to predict the accuracy with which the volume-integrated total radiated power can be estimated from the measurements by a resistive bolometer diagnostic, considering, in particular, its line-of-sight geometry, étendues of individual lines of sight, bolometer-sensor characteristics, and the expected noise level that can be obtained with its electronics and signal chain. The methodology depends on a number of assumptions in order to arrive at analytical expressions but does not restrict the final implementation of data-processing of the diagnostic measurements. The methodology allows us to predict the performance in terms of accuracy, total-radiated power level, and frequency or time resolution and to optimize bolometer-sensor characteristics for a set of performance requirements. This is illustrated for the bolometer diagnostic that is being designed for the ITER experiment. The reasonableness, consequences, and limitations of the assumptions are discussed in detail.