Sina Jahanbakhsh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sina Jahanbakhsh has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Murat Celik
Department of Mechanical Engineering, Bogazici University, Istanbul 34342, Türkiye
4 shared publications - Ronny Brandenburg
Leibniz Institute for Plasma Science and Technology, Felix-Hausdorff-Str. 2, 17489 Greifswald, Germany
4 shared publications - Hans Meister
Max-Planck-Institute for Plasmaphysics, Garching, Germany
3 shared publications - L. C. Ingesson
Fusion for Energy 3 , c/ Josep Pla, n°2, Torres Diagonal Litoral, Edificio B3, 08019 Barcelona, Spain
2 shared publications Volker Brüser
Leibniz Institute for Plasma Science and Technology, Greifswald, Mecklenburg-Vorpommern, GERMANY
2 shared publications- A. Gandhi
ADF Group, La Bastide Blanche—Bât G 3 , 13127 Vitrolles, France
1 shared publication
Latest Publications
- Open Access
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Effects of neutral gas pressure on calibration parameters of resistive bolometer sensors in fusion devices
Ambient pressure may influence the thermal path between the absorber and heat sink of resistive bolometers and thus impact the calibration parameters. This effect is investigated for metal resistive bolometer sensors as used in bolometer diagnostics on fusion experiments. Measurements in the test facility IBOVAC indicate that pressure has no effect up to 10−3 mbar. However, a significant change in the cooling time constant is observed for pressures above 10−2 mbar, a reduction up to a factor of three at 1 mbar. The measurements performed in N2 and He atmospheres and simulations in H2 indicate no difference between the results from different gas species up to 10−3 mbar and less than 10 % up to 0.1 mbar. A model based on the thermal conductivity of the surrounding gas combined with the geometry of the sensor holder successfully demonstrates that the additional cooling path through the gas, which may vary between the measurement and reference absorbers, can explain the measurement results. Applying the model to the geometry of a sensor holder designed for port-mounted bolometer cameras in ITER led to design modifications that should help reduce the impact of high environmental pressures on the bolometer measurements. Similarly, it can be assumed that applying the model to the geometries and sensors of operating bolometer diagnostics can help correct the measurements and improve the understanding of plasma radiation in the case of high pressures at the location of bolometer sensors.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Open AccessEffects of neutral gas pressure on calibration parameters of resistive bolometer sensors in fusion devices
Ambient pressure may influence the thermal path between the absorber and heat sink of resistive bolometers and thus impact the calibration parameters. This effect is investigated for metal resistive bolometer sensors as used in bolometer diagnostics on fusion experiments. Measurements in the test facility IBOVAC indicate that pressure has no effect up to 10−3 mbar. However, a significant change in the cooling time constant is observed for pressures above 10−2 mbar, a reduction up to a factor of three at 1 mbar. The measurements performed in N2 and He atmospheres and simulations in H2 indicate no difference between the results from different gas species up to 10−3 mbar and less than 10 % up to 0.1 mbar. A model based on the thermal conductivity of the surrounding gas combined with the geometry of the sensor holder successfully demonstrates that the additional cooling path through the gas, which may vary between the measurement and reference absorbers, can explain the measurement results. Applying the model to the geometry of a sensor holder designed for port-mounted bolometer cameras in ITER led to design modifications that should help reduce the impact of high environmental pressures on the bolometer measurements. Similarly, it can be assumed that applying the model to the geometries and sensors of operating bolometer diagnostics can help correct the measurements and improve the understanding of plasma radiation in the case of high pressures at the location of bolometer sensors.
- 1 January 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (1)
Generic approach to assess the measuring performance of total-radiated power quantities by multi-channel resistive bolometer diagnostics on fusion experiments
On present-day magnetic-confinement fusion experiments, the performance of multi-channel bolometer diagnostics has typically evolved over time through experience with earlier versions of the diagnostic and experimental results obtained. For future large-scale fusion experiments and reactors, it is necessary to be able to predict the performance as a function of design decisions and constraints. A methodology has been developed to predict the accuracy with which the volume-integrated total radiated power can be estimated from the measurements by a resistive bolometer diagnostic, considering, in particular, its line-of-sight geometry, étendues of individual lines of sight, bolometer-sensor characteristics, and the expected noise level that can be obtained with its electronics and signal chain. The methodology depends on a number of assumptions in order to arrive at analytical expressions but does not restrict the final implementation of data-processing of the diagnostic measurements. The methodology allows us to predict the performance in terms of accuracy, total-radiated power level, and frequency or time resolution and to optimize bolometer-sensor characteristics for a set of performance requirements. This is illustrated for the bolometer diagnostic that is being designed for the ITER experiment. The reasonableness, consequences, and limitations of the assumptions are discussed in detail.
- 1 January 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (1)
Generic approach to assess the measuring performance of total-radiated power quantities by multi-channel resistive bolometer diagnostics on fusion experiments
On present-day magnetic-confinement fusion experiments, the performance of multi-channel bolometer diagnostics has typically evolved over time through experience with earlier versions of the diagnostic and experimental results obtained. For future large-scale fusion experiments and reactors, it is necessary to be able to predict the performance as a function of design decisions and constraints. A methodology has been developed to predict the accuracy with which the volume-integrated total radiated power can be estimated from the measurements by a resistive bolometer diagnostic, considering, in particular, its line-of-sight geometry, étendues of individual lines of sight, bolometer-sensor characteristics, and the expected noise level that can be obtained with its electronics and signal chain. The methodology depends on a number of assumptions in order to arrive at analytical expressions but does not restrict the final implementation of data-processing of the diagnostic measurements. The methodology allows us to predict the performance in terms of accuracy, total-radiated power level, and frequency or time resolution and to optimize bolometer-sensor characteristics for a set of performance requirements. This is illustrated for the bolometer diagnostic that is being designed for the ITER experiment. The reasonableness, consequences, and limitations of the assumptions are discussed in detail.
- Open Access
- 1 March 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (3) , 033503
Calibration and thermal test results of prototype bolometer sensors for ITER fusion reactor
For over 10 years, several bolometer sensors with different properties have been tested in the IBOVAC facility. The aim has been to develop a bolometer sensor that can be operated in ITER and can withstand harsh operating conditions. For this purpose, important physical properties of the sensors, i.e., cooling time constant τ, normalized heat capacity κ, and normalized sensitivity sn, have been characterized in a vacuum condition and at various temperatures up to 300 °C. The calibration is achieved by ohmic heating of the sensor absorbers by applying a DC voltage and recording exponential current fall during heating. Recently, a Python program was developed to analyze the data and extract the above mentioned parameters including the uncertainties from recorded currents. In the present series of experiments, the latest prototype sensors developed for ITER are tested and evaluated. These include three different sensor types: two with Au absorbers on ZrO2 membranes (self-supporting substrate sensors) and one with Au absorbers on Si3N4 membranes supported by a Si frame (supported membrane sensors). Tests revealed that the sensor with ZrO2 substrate can only be operated up to 150 °C, while the supported membrane sensors passed the tests up to 300 °C successfully. These results will be used, together with other upcoming tests, such as irradiation testing, to select the most suitable sensors to be employed in ITER.
- 1 March 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (3) , 033503
Open AccessCalibration and thermal test results of prototype bolometer sensors for ITER fusion reactor
For over 10 years, several bolometer sensors with different properties have been tested in the IBOVAC facility. The aim has been to develop a bolometer sensor that can be operated in ITER and can withstand harsh operating conditions. For this purpose, important physical properties of the sensors, i.e., cooling time constant τ, normalized heat capacity κ, and normalized sensitivity sn, have been characterized in a vacuum condition and at various temperatures up to 300 °C. The calibration is achieved by ohmic heating of the sensor absorbers by applying a DC voltage and recording exponential current fall during heating. Recently, a Python program was developed to analyze the data and extract the above mentioned parameters including the uncertainties from recorded currents. In the present series of experiments, the latest prototype sensors developed for ITER are tested and evaluated. These include three different sensor types: two with Au absorbers on ZrO2 membranes (self-supporting substrate sensors) and one with Au absorbers on Si3N4 membranes supported by a Si frame (supported membrane sensors). Tests revealed that the sensor with ZrO2 substrate can only be operated up to 150 °C, while the supported membrane sensors passed the tests up to 300 °C successfully. These results will be used, together with other upcoming tests, such as irradiation testing, to select the most suitable sensors to be employed in ITER.
- 1 January 2020
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 29 (1) , 015001
Experimental investigation of single microdischarges in a barrier corona arrangement with a cathodic metal pin
Microdischarges (MDs) in a sinusoidally driven barrier corona discharge, operated in dry air at atmospheric pressure, are investigated using time-correlated single photon counting (TC-SPC) technique, electrical measurements (applied voltage and current pulses) and ICCD images. In the current contribution, results of the cathodic pin half-cycle are presented. Results of the anodic pin half-cycle were presented in a previous study (Jahanbakhsh et al 2018 Plasma Sources Sci. Technol. 27 115011). In the cathodic pin half-cycle appearance phase and current pulse amplitude of the MDs have an erratic behavior. Hence, a statistical study of the current pulse amplitudes is conducted, and it is correlated to the phase-resolved spatio-temporal development of the MDs, obtained from TC-SPC recordings. This study indicates that the breakdown and development of the MDs is dependent on their inception phase, which is related to the discharge activity in preceding (anodic pin) half-cycles. It is shown that the MDs appearing at lower applied voltages are ignited with a positive streamer starting near the anode (dielectric), similar to single dielectric barrier discharge MDs. On the other hand, the inception of the MDs appearing at higher applied voltages takes place with a double-streamer mechanism starting near the tip of the cathode (pin). These MDs have similarities to transient sparks, in particular much higher current pulse amplitudes compared to single DBDs.
- 1 January 2020
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 29 (1) , 015001
Experimental investigation of single microdischarges in a barrier corona arrangement with a cathodic metal pin
Microdischarges (MDs) in a sinusoidally driven barrier corona discharge, operated in dry air at atmospheric pressure, are investigated using time-correlated single photon counting (TC-SPC) technique, electrical measurements (applied voltage and current pulses) and ICCD images. In the current contribution, results of the cathodic pin half-cycle are presented. Results of the anodic pin half-cycle were presented in a previous study (Jahanbakhsh et al 2018 Plasma Sources Sci. Technol. 27 115011). In the cathodic pin half-cycle appearance phase and current pulse amplitude of the MDs have an erratic behavior. Hence, a statistical study of the current pulse amplitudes is conducted, and it is correlated to the phase-resolved spatio-temporal development of the MDs, obtained from TC-SPC recordings. This study indicates that the breakdown and development of the MDs is dependent on their inception phase, which is related to the discharge activity in preceding (anodic pin) half-cycles. It is shown that the MDs appearing at lower applied voltages are ignited with a positive streamer starting near the anode (dielectric), similar to single dielectric barrier discharge MDs. On the other hand, the inception of the MDs appearing at higher applied voltages takes place with a double-streamer mechanism starting near the tip of the cathode (pin). These MDs have similarities to transient sparks, in particular much higher current pulse amplitudes compared to single DBDs.
- 20 November 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 126 (19) , 193305
Correlation between electric field, current and photon emission in subsequent barrier corona microdischarges
We investigate single microdischarges (MDs) in a sinusoidally operated barrier corona discharge in air. For the voltage amplitude being applied, two subsequent MDs appear in the anodic pin half-cycle. The developments of these subsequent MDs were studied and presented in detail in a previous contribution [Jahanbakhsh et al., Plasma Sources Sci. Technol. 27, 115011 (2018)]. In the present study, the reduced electric field strength ( ) values of the MDs are determined. In addition, the current pulses are synchronized, with a subnanosecond time resolution, to the spatiotemporally resolved light emission and development of the MDs. It is proposed that the current pulse derivative maximum corresponds to the streamer head arrival on the cathode surface. Therefore, the derivatives of the current pulses are used to synchronize the light emission and current measurements. Based on this synchronization, spatiotemporally resolved light emissions at different positions are compared to the averaged current pulses. Considering the observed correlations, it is proposed that after the arrival of the streamer head on the dielectric (cathode) surface and bulk plasma formation, the ionization processes near the dielectric surface are the dominant source of electron current production. The determination of the is based on the analysis of the time-correlated single photon counting results for the molecular states of the first negative and the second positive systems of nitrogen. The increases during the streamer propagation in the gap, reaching its maximum value at the impact of the streamer on the cathode. The values for the second group MDs are lower only in the vicinity of the dielectric surface, which can be attributed to the positive residual surface charges from the first group MDs.- 20 November 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 126 (19) , 193305
Correlation between electric field, current and photon emission in subsequent barrier corona microdischarges
We investigate single microdischarges (MDs) in a sinusoidally operated barrier corona discharge in air. For the voltage amplitude being applied, two subsequent MDs appear in the anodic pin half-cycle. The developments of these subsequent MDs were studied and presented in detail in a previous contribution [Jahanbakhsh et al., Plasma Sources Sci. Technol. 27, 115011 (2018)]. In the present study, the reduced electric field strength ( ) values of the MDs are determined. In addition, the current pulses are synchronized, with a subnanosecond time resolution, to the spatiotemporally resolved light emission and development of the MDs. It is proposed that the current pulse derivative maximum corresponds to the streamer head arrival on the cathode surface. Therefore, the derivatives of the current pulses are used to synchronize the light emission and current measurements. Based on this synchronization, spatiotemporally resolved light emissions at different positions are compared to the averaged current pulses. Considering the observed correlations, it is proposed that after the arrival of the streamer head on the dielectric (cathode) surface and bulk plasma formation, the ionization processes near the dielectric surface are the dominant source of electron current production. The determination of the is based on the analysis of the time-correlated single photon counting results for the molecular states of the first negative and the second positive systems of nitrogen. The increases during the streamer propagation in the gap, reaching its maximum value at the impact of the streamer on the cathode. The values for the second group MDs are lower only in the vicinity of the dielectric surface, which can be attributed to the positive residual surface charges from the first group MDs.- Open Access
- 15 March 2019
- Published by Springer Nature in Plasma Chemistry and Plasma Processing
- Vol. 39 (3) , 667-682
About the Development and Dynamics of Microdischarges in Toluene-Containing Air
- 15 March 2019
- Published by Springer Nature in Plasma Chemistry and Plasma Processing
- Vol. 39 (3) , 667-682
Open AccessAbout the Development and Dynamics of Microdischarges in Toluene-Containing Air
- 1 November 2018
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 27 (11) , 115011
Single microdischarges in a barrier corona arrangement with an anodic metal pin: discharge characteristics in subsequent breakdowns
Metal pin-to-dielectric-covered electrode arrangements can be considered as a combination of corona discharge and dielectric barrier discharge. In the current study, the discharge is operated in dry air at atmospheric pressure. Sinusoidal voltage is applied to the dielectric-covered hemispherical electrode, and the metal pin electrode is grounded. Using an ICCD camera and a current probe (Rogowski coil), images and current pulses of single microdischarges (MDs) are recorded simultaneously. In addition, a time-correlated single photon counting technique is used to record the spatio-temporally resolved development of the MDs. The appearance and properties of the MDs in the two polarities of the applied voltage differ significantly. In this contribution, only the results of the negative half-cycle, i.e. anodic pin, are presented. In this half-cycle, for the voltage amplitude being applied, two MDs appear in each applied voltage cycle. The first MDs leave a positive charge on the surface of the dielectric, which has considerable influence on the propagation and properties of the second MDs, namely slower propagation of the cathode directed streamer in the dielectric vicinity, further expansion of the plasma on the dielectric surface and longer presence of the bulk plasma in the gap.
- 1 November 2018
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 27 (11) , 115011
Single microdischarges in a barrier corona arrangement with an anodic metal pin: discharge characteristics in subsequent breakdowns
Metal pin-to-dielectric-covered electrode arrangements can be considered as a combination of corona discharge and dielectric barrier discharge. In the current study, the discharge is operated in dry air at atmospheric pressure. Sinusoidal voltage is applied to the dielectric-covered hemispherical electrode, and the metal pin electrode is grounded. Using an ICCD camera and a current probe (Rogowski coil), images and current pulses of single microdischarges (MDs) are recorded simultaneously. In addition, a time-correlated single photon counting technique is used to record the spatio-temporally resolved development of the MDs. The appearance and properties of the MDs in the two polarities of the applied voltage differ significantly. In this contribution, only the results of the negative half-cycle, i.e. anodic pin, are presented. In this half-cycle, for the voltage amplitude being applied, two MDs appear in each applied voltage cycle. The first MDs leave a positive charge on the surface of the dielectric, which has considerable influence on the propagation and properties of the second MDs, namely slower propagation of the cathode directed streamer in the dielectric vicinity, further expansion of the plasma on the dielectric surface and longer presence of the bulk plasma in the gap.
- 3 November 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02B922
Study of electron current extraction from a radio frequency plasma cathode designed as a neutralizer for ion source applications
Plasma cathodes are insert free devices that are developed to be employed as electron sources in electric propulsion and ion source applications as practical alternatives to more commonly used hollow cathodes. Inductively coupled plasma cathodes, or Radio Frequency (RF) plasma cathodes, are introduced in recent years. Because of its compact geometry, and simple and efficient plasma generation, RF plasma source is considered to be suitable for plasma cathode applications. In this study, numerous RF plasma cathodes have been designed and manufactured. Experimental measurements have been conducted to study the effects of geometric and operational parameters. Experimental results of this study show that the plasma generation and electron extraction characteristics of the RF plasma cathode device strongly depend on the geometric parameters such as chamber diameter, chamber length, orifice diameter, orifice length, as well as the operational parameters such as RF power and gas mass flow rate.
- 3 November 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02B922
Study of electron current extraction from a radio frequency plasma cathode designed as a neutralizer for ion source applications
Plasma cathodes are insert free devices that are developed to be employed as electron sources in electric propulsion and ion source applications as practical alternatives to more commonly used hollow cathodes. Inductively coupled plasma cathodes, or Radio Frequency (RF) plasma cathodes, are introduced in recent years. Because of its compact geometry, and simple and efficient plasma generation, RF plasma source is considered to be suitable for plasma cathode applications. In this study, numerous RF plasma cathodes have been designed and manufactured. Experimental measurements have been conducted to study the effects of geometric and operational parameters. Experimental results of this study show that the plasma generation and electron extraction characteristics of the RF plasma cathode device strongly depend on the geometric parameters such as chamber diameter, chamber length, orifice diameter, orifice length, as well as the operational parameters such as RF power and gas mass flow rate.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 635-638
Space propulsion research vacuum facility of the Bogazici University space technologies laboratory
Development of reliable, successful and robust technologies for space systems demands realistic testing facilities. Low pressure levels are required for simulating the space vacuum conditions in earth's orbit or interplanetary-space. Therefore, establishment of a vacuum facility devoted specifically to the testing of thrusters is needed in order to develop, study and test thrusters to be deployed on spacecraft or satellites. In this study, the design, acquisition and manufacturing processes, and capabilities of a 1.5 m diameter and 2.7 m long cylindrical vacuum facility, that will primarily be used for the development and testing of electric spacecraft thrusters, at the Bogazici University Space Technologies Laboratory (BUSTLab) are presented.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 635-638
Space propulsion research vacuum facility of the Bogazici University space technologies laboratory
Development of reliable, successful and robust technologies for space systems demands realistic testing facilities. Low pressure levels are required for simulating the space vacuum conditions in earth's orbit or interplanetary-space. Therefore, establishment of a vacuum facility devoted specifically to the testing of thrusters is needed in order to develop, study and test thrusters to be deployed on spacecraft or satellites. In this study, the design, acquisition and manufacturing processes, and capabilities of a 1.5 m diameter and 2.7 m long cylindrical vacuum facility, that will primarily be used for the development and testing of electric spacecraft thrusters, at the Bogazici University Space Technologies Laboratory (BUSTLab) are presented.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 593-597
Experimental investigation of operational parameters of a prototype radio frequency plasma cathode
Plasma cathodes have attracted much attention in recent years, and various types of such cathodes have been developed and tested by different research groups. In these types of electron sources, a bulk plasma is generated inside a vessel, which has an orifice at its front plate. Then, by applying a positive potential outside the vessel, electrons of the bulk plasma are extracted from this orifice. Various plasma sources, such as helicon, electron cyclotron resonance (ECR), microwave and radio frequency (RF) are used for the bulk plasma generation of the plasma cathode devices. Compact geometry, easy generation, and high density and efficiency of the RF plasma make it preferable for the plasma cathode applications. In this study, the operation procedures and characteristics of a prototype RF cathode device are described. In addition, some experimental results from the testing of the prototype RF cathode are presented.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 593-597
Experimental investigation of operational parameters of a prototype radio frequency plasma cathode
Plasma cathodes have attracted much attention in recent years, and various types of such cathodes have been developed and tested by different research groups. In these types of electron sources, a bulk plasma is generated inside a vessel, which has an orifice at its front plate. Then, by applying a positive potential outside the vessel, electrons of the bulk plasma are extracted from this orifice. Various plasma sources, such as helicon, electron cyclotron resonance (ECR), microwave and radio frequency (RF) are used for the bulk plasma generation of the plasma cathode devices. Compact geometry, easy generation, and high density and efficiency of the RF plasma make it preferable for the plasma cathode applications. In this study, the operation procedures and characteristics of a prototype RF cathode device are described. In addition, some experimental results from the testing of the prototype RF cathode are presented.