Screw Angulation and Insertion Sequence Increase Interfragmentary Compression When Using Plates for Midfoot Arthrodesis: Foam-Surrogate and Cadaveric Validation
Open Access
- 28 October 2025
- journal article
- Published by SAGE Publications in Foot & Ankle Orthopaedics
- Vol. 10 (4)
Abstract
Background: Achieving interfragmentary compression and stability is critical for successful bone healing in fracture fixation and arthrodesis procedures. Modern orthopaedic plating systems incorporating variable-angle screw designs offer greater versatility; however, the impact of screw trajectory on interfragmentary compression and contact area has not been adequately explored. We questioned if the resultant forces applied by screw orientation would follow the basic principles of vector geometry. Methods: Interfragmentary compression and contact area were quantified in foam bone surrogate osteotomy models using plates allowing maximum screw angulation of either 15 or 30 degrees, with screws inserted at various angles. Cadaveric second-tarsometatarsal (TMT) arthrodesis constructs were subsequently used to validate the mechanical findings from surrogate testing. Results: Compression and contact area increased from 0 degrees to 15 degrees to 30 degrees in surrogate models (overall analysis of variance P < .001). Angling screws in the second bone fragment after securing the plate to the first fragment produced the largest compression gains. In cadaveric second-TMT constructs, 30-degree divergence increased compression (~15-fold; 49.4 ± 35.1 N vs 3.4 ± 3.8 N; P < .001) and contact area (~4-fold; 47.8 ± 28.9 mm ² vs 12.8 ± 7.3 mm ² ; P < .001) compared with 0-degree divergence. Conclusion: With plate fixation, screw divergence from the arthrodesis/fracture line improved interfragmentary compression and contact area, particularly when divergent screws were inserted into the second bone fragment after the plate was secured to the first fragment. As hypothesized, the findings followed basic vector geometry. Clinical Relevance: Surgeons can optimize plate fixation quality and enhance stability in midfoot arthrodesis (and other procedures) by strategically angling locking screws in the second bone fragment after securing the plate to the first fragment. These biomechanical insights offer practical guidance for achieving superior interfragmentary compression and potentially reducing the risk of nonunion in clinical practice.Keywords
This publication has 21 references indexed in Scilit:
- The biomechanical cost of variable angle locking screwsInjury, 2016
- Concept of variable angle locking—evolution and mechanical evaluation of a recent technologyJournal of Orthopaedic Research, 2015
- A biomechanical study comparing polyaxial locking screw mechanismsInjury, 2013
- The influence of compression on the healing of experimental tibial fracturesInjury, 2011
- Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fracturesInternational Orthopaedics, 2011
- The strength of polyaxial locking interfaces of distal radius platesClinical Biomechanics, 2009
- Biomechanical Comparison of Polyaxial-Type Locking Plates and a Fixed-Angle Locking Plate for Internal Fixation of Distal Femur FracturesJournal of Orthopaedic Trauma, 2009
- Biomechanical Comparison of Polyaxial and Uniaxial Locking Plate Fixation in a Proximal Tibial Gap ModelJournal of Orthopaedic Trauma, 2009
- Polyaxial Locking Plate Fixation in Distal Femur Fractures: A Biomechanical ComparisonJournal of Orthopaedic Trauma, 2008
- Strain Rate and Timing of Stimulation in Mechanical Modulation of Fracture HealingClinical Orthopaedics and Related Research, 1998