Quantitative performance of advanced resolution recovery strategies on SPECT images: evaluation with use of digital phantom models
Authors:
- 13 July 2012
- journal article
- research article
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 6 (1) , 42-53
Abstract
Several resolution recovery (RR) methods have been developed. This study was aimed to validate the following performance of the advanced RR methods: Evolution™, Astonish™, Flash3D™, and 3D-OSEM. We compared the advanced RR method with filtered back projection (FBP) and standard order-subset expectation maximization (OSEM) using resolution (RES), cylinder/sphere (CYS), and myocardial (MYD) digital phantoms. The RES phantom was placed in three spheres. Sixteen spheres (hot and cold) were then placed in a concentric configuration (diameter: 96–9.6 mm) inside the CYS phantom. The MYD phantom was created by computer simulation with the use of an electron γ-shower 4 (EGS4) and it included two left ventricular defects in the myocardium. The performance was evaluated at source-to-detector distances (R-distance) of 166, 200, and 250 mm with reconstruction parameters (product of subset and iteration: SI) with use of the resolution recovery factor, count recovery, normalized mean square error (NMSE), and %CV. According to increased SI updates, the value of the FWHM decreased, and the effect was more obvious as the R-distance increased. The spatial resolution of the advanced RR method was 20 % better than that of FBP and OSEM. The resolution recovery ratio was 80 %, and the count recovery was maintained only in objects with a diameter of >30 mm in the advanced RR method. The NMSE and %CV was 50 and 30 % improved over FBP and OSEM, respectively. The advanced RR method caused overestimation due to Gibbs’s phenomenon in the marginal region when the diameter of the sphere was 16–28.8 mm.Keywords
This publication has 23 references indexed in Scilit:
- Comparison of advanced iterative reconstruction methods for SPECT/CTZeitschrift für Medizinische Physik, 2012
- Clinical usefulness of a collimator distance dependent resolution recovery in myocardial perfusion SPECT: a clinical report from a single instituteAnnals of Nuclear Medicine, 2010
- Quantitative Accuracy of Clinical 99mTc SPECT/CT Using Ordered-Subset Expectation Maximization with 3-Dimensional Resolution Recovery, Attenuation, and Scatter CorrectionJournal of Nuclear Medicine, 2010
- A multi-center phantom study comparing image resolution from three state-of-the-art SPECT-CT systemsJournal of Nuclear Cardiology, 2009
- Wide beam reconstruction “quarter-time” gated myocardial perfusion SPECT functional imaging: a comparison to “full-time” ordered subset expectation maximumJournal of Nuclear Cardiology, 2009
- Half-Time SPECT Myocardial Perfusion Imaging with Attenuation CorrectionJournal of Nuclear Medicine, 2009
- Ordered subset expectation maximization and wide beam reconstruction “half-time” gated myocardial perfusion SPECT functional imaging: A comparison to “full-time” filtered backprojectionJournal of Nuclear Cardiology, 2008
- 16.08Journal of Nuclear Cardiology, 2006
- Application of task-based measures of image quality to optimization and evaluation of three-dimensional reconstruction-based compensation methods in myocardial perfusion SPECTIEEE Transactions on Medical Imaging, 2002
- Noniterative compensation for the distance-dependent detector response and photon attenuation in SPECT imagingIEEE Transactions on Medical Imaging, 1994