Dosimetric Characterization of an Inorganic Optical Fiber Sensor for External Beam Radiation Therapy
- 6 December 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (6) , 2140-2147
Abstract
The aim of this study was to investigate the dosimetric performance of a novel optical fiber sensor for use in external beam radiation therapy. Repeatability and reproducibility of the output signal, linearity, dose rate and dose per pulse dependence were evaluated. Angular dependence was investigated in the axial and azimuthal planes. The percentage depth dose and lateral dose profiles were measured using the optical fiber sensor system and compared to commercially available detectors such as Exradin W1 plastic scintillator and a PTW-microdiamond detector. The result of this study show that the optical fiber sensor system has good repeatability and reproducibility of the output signal with a maximum deviation of 0.17% and 1.00%, respectively. The system also showed an excellent linearity with dose, and its signal was independent of dose rate. However, the system showed a strong dependence on dose per pulse with 27% deviation from the W1 result at the highest dose per pulse value that was achieved at 75 cm source to surface distance. The system also showed an angular dependence when the incident beam was in the azimuthal plane due to the geometry of the scintillator at the tip of the fiber. The optical fiber sensor over-responded when measuring percentage depth dose curves and lateral dose profiles due in part to the sensitivity of the scintillating material (Gd2O2S:Tb) to low energy scattered radiation. However, further investigation is needed to quantify the overall contribution of Cerenkov radiation to the over-response of the optical fiber sensor.Keywords
Funding Information
- Royal Society (UF150618)
- Royal Embassy of Saudi Arabia through a Saudi Arabia Government Scholarship
This publication has 19 references indexed in Scilit:
- Dosimetric characterization of the Exradin W1 plastic scintillator detector through comparison with an in-house developed scintillator systemRadiation Measurements, 2014
- Optical dosimetry of radiotherapy beams using Cherenkov radiation: the relationship between light emission and dosePhysics in Medicine & Biology, 2014
- In vivo dosimetry in external beam radiotherapyMedical Physics, 2013
- Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: A comparison study of calibration procedures and validation in Cerenkov light‐dominated situationsMedical Physics, 2011
- Task Group 142 report: Quality assurance of medical acceleratorsa)Medical Physics, 2009
- Spectral discrimination of Čerenkov radiation in scintillating dosimetersMedical Physics, 2005
- Real-time optical-fibre luminescence dosimetry for radiotherapy: physical characteristics and applications in photon beamsPhysics in Medicine & Biology, 2004
- Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40Medical Physics, 1994
- Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerationsPhysics in Medicine & Biology, 1992
- Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurementsPhysics in Medicine & Biology, 1992