Q. Gorit
Research Subjects
Q. Gorit has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Benoit Lacroix
CEA-IRFM, St-Paul Lez Durance, France
4 shared publications - Alexandre Torre
CEA, IRFM, Centre de Cadarache, Saint-Paul-lez-Durance, France
3 shared publications S. Nicollet
3 shared publicationsA. Louzguiti
2 shared publicationsA. Torre
2 shared publications- Alexandre Louzguiti
ITER Organization, Saint-Paul-lez-Durance, France
2 shared publications
Latest Publications
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-6
Application of Neon Pulsating Heat Pipes to a Cryocooler-Based HTS Coil
Pulsating heat pipes (PHPs) are passive devices using thermally induced two-phase flow. They are increasingly studied in cryogenic conditions to improve heat transfer between cryocoolers and high temperature superconducting (HTS) coils. This paper presents the application of two neon PHPs in simulta neous operation transferring the heat load from an insulated HTS coil under alternating current (AC) operation to a cryocooler. The main objective is to demonstrate the feasibility and quantify the potential benefits of using PHPs for this application. The PHPs, the coil, the experimental setup, procedures and campaigns are described. The experimental results of the coil cooldown and of the AC operation, with cycles of current ramping at 500A/s between 0 and 500A, are analyzed and discussed. The maximum magnetic field at the center of the coil is measured at 0.43T and AC losses dissipate an average heat load of nearly 6.5W. The PHP parameters tested include condenser temperatures of 27 and 30K, as well as filling ratios ranging from 37 to 56%. The two neon PHPs effectively transfer the heat while guaranteeing a low thermal resistance (0.18 to 0.24K/W) and without dry-out phenomenon across four experiments. On average, the temperature difference over the thermal buses is reduced by almost 80% compared to an equivalent copper rod, demonstrating the potential of PHPs for this application.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-6
Application of Neon Pulsating Heat Pipes to a Cryocooler-Based HTS Coil
Pulsating heat pipes (PHPs) are passive devices using thermally induced two-phase flow. They are increasingly studied in cryogenic conditions to improve heat transfer between cryocoolers and high temperature superconducting (HTS) coils. This paper presents the application of two neon PHPs in simulta neous operation transferring the heat load from an insulated HTS coil under alternating current (AC) operation to a cryocooler. The main objective is to demonstrate the feasibility and quantify the potential benefits of using PHPs for this application. The PHPs, the coil, the experimental setup, procedures and campaigns are described. The experimental results of the coil cooldown and of the AC operation, with cycles of current ramping at 500A/s between 0 and 500A, are analyzed and discussed. The maximum magnetic field at the center of the coil is measured at 0.43T and AC losses dissipate an average heat load of nearly 6.5W. The PHP parameters tested include condenser temperatures of 27 and 30K, as well as filling ratios ranging from 37 to 56%. The two neon PHPs effectively transfer the heat while guaranteeing a low thermal resistance (0.18 to 0.24K/W) and without dry-out phenomenon across four experiments. On average, the temperature difference over the thermal buses is reduced by almost 80% compared to an equivalent copper rod, demonstrating the potential of PHPs for this application.
- Open Access
- 16 June 2025
- Published by Elsevier in Cryogenics
- Vol. 150
Experimental characterization of neon pulsating heat pipes for cryocooler-based HTS magnets
- 16 June 2025
- Published by Elsevier in Cryogenics
- Vol. 150
Open AccessExperimental characterization of neon pulsating heat pipes for cryocooler-based HTS magnets
- 30 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-6
Thermohydraulical Analysis and Fast Assessment of Operating Windows for JT-60SA TFC Commissioning
JT-60SA Toroidal Field Coils (TFC) comprise each a Winding Pack (WP), with 6 Cable-In-Conduit Conductor (CICC) lengths wound in 6 double-pancakes operating at 25.7 kA nominal current and 4.7 K temperature as well as stainless steel casing cooled by forced flow channels. Second phase of Integrated Commissioning (IC) have been performed during 2023 with current discharge and induced AC losses in the CICC and eddy currents in the structures. A Fast Assessment of Operating Window (FAOW) model was developed for this purpose and permits to assess heat loads inputs, the heat transfer from casing to WP with inertia effect and time delay, and the cooling capacities (through heat exchanger). This FAOW model is coupled to Superconductors Thermohydraulical and Resistive Electrical Analytical Model (STREAM) and permits to evaluate helium pressure and temperature increase in cooling loop. The IC 18 kA current discharge measurements are compared to calculated results thus validating models and analyses. Predictive calculated results for other current discharge values (15, 18, 20, 23.7 and 25.7 kA) are presented and discussed with the maximal helium pressure limits, and safety aspects (induced relief valves opening or not). These analyses of current values operating windows have been confirmed by further plasma operation at 23.7 kA. Even if the limits of the model are discussed, the main interest consists of rapid execution time duration (only few minutes) compared to numerical codes (several hours). This work and fast analysis tool and model (FAOW-STREAM) can be also useful for further performances analyses in view to recommend their use in similar ITER or EU-DEMO magnets, with possibility of real-time feed-forward calculations/control.
- 30 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-6
Thermohydraulical Analysis and Fast Assessment of Operating Windows for JT-60SA TFC Commissioning
JT-60SA Toroidal Field Coils (TFC) comprise each a Winding Pack (WP), with 6 Cable-In-Conduit Conductor (CICC) lengths wound in 6 double-pancakes operating at 25.7 kA nominal current and 4.7 K temperature as well as stainless steel casing cooled by forced flow channels. Second phase of Integrated Commissioning (IC) have been performed during 2023 with current discharge and induced AC losses in the CICC and eddy currents in the structures. A Fast Assessment of Operating Window (FAOW) model was developed for this purpose and permits to assess heat loads inputs, the heat transfer from casing to WP with inertia effect and time delay, and the cooling capacities (through heat exchanger). This FAOW model is coupled to Superconductors Thermohydraulical and Resistive Electrical Analytical Model (STREAM) and permits to evaluate helium pressure and temperature increase in cooling loop. The IC 18 kA current discharge measurements are compared to calculated results thus validating models and analyses. Predictive calculated results for other current discharge values (15, 18, 20, 23.7 and 25.7 kA) are presented and discussed with the maximal helium pressure limits, and safety aspects (induced relief valves opening or not). These analyses of current values operating windows have been confirmed by further plasma operation at 23.7 kA. Even if the limits of the model are discussed, the main interest consists of rapid execution time duration (only few minutes) compared to numerical codes (several hours). This work and fast analysis tool and model (FAOW-STREAM) can be also useful for further performances analyses in view to recommend their use in similar ITER or EU-DEMO magnets, with possibility of real-time feed-forward calculations/control.
- 18 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Heat Transfer Coefficient Measurement in Single Channel Cable-in-Conduit Conductor
Cable-in-conduit conductors (CICC) compose superconducting magnets of tokamaks and are cooled with 4 K supercritical helium forced flow, to provide efficient heat removal and thermal stability of the superconducting state. Nowadays, thermal couplings between fluid and solids are ill-characterized for such cables. We consequently measured global heat transfer interphase coefficients at macro scale. An experimental set-up associated with an inverse method and a direct three temperatures thermal-hydraulic model have been developed to obtain representative data. Transient experiments of forced flow with heat pulses imposing thermal disequilibrium between fluid and solids have been performed. Results are correlated to actual geometric properties obtained from 3D tomography. 1D three temperatures model of the two phases (bundle/nitrogen) along with the jacket, thermally coupled by convection is solved using finite volume method with an implicit and upstream scheme. Results are compared to available literature data.
- 18 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Heat Transfer Coefficient Measurement in Single Channel Cable-in-Conduit Conductor
Cable-in-conduit conductors (CICC) compose superconducting magnets of tokamaks and are cooled with 4 K supercritical helium forced flow, to provide efficient heat removal and thermal stability of the superconducting state. Nowadays, thermal couplings between fluid and solids are ill-characterized for such cables. We consequently measured global heat transfer interphase coefficients at macro scale. An experimental set-up associated with an inverse method and a direct three temperatures thermal-hydraulic model have been developed to obtain representative data. Transient experiments of forced flow with heat pulses imposing thermal disequilibrium between fluid and solids have been performed. Results are correlated to actual geometric properties obtained from 3D tomography. 1D three temperatures model of the two phases (bundle/nitrogen) along with the jacket, thermally coupled by convection is solved using finite volume method with an implicit and upstream scheme. Results are compared to available literature data.
- 20 February 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 191
A simplified 1-D quench model for preliminary prediction applied to JT-60SA toroidal field coil
- 20 February 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 191
A simplified 1-D quench model for preliminary prediction applied to JT-60SA toroidal field coil
- 3 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Thermal Hydraulic Analysis of JT-60SA TFC02 Complementary Quench Tests in CTF
In the framework of JT-60SA tokamak commissioning (Japan, 2021), the 20 Toroidal Field Coils (TFC) were tested at the Cold Test Facility (CTF) at CEA-Saclay (France, 2018) and submitted to quench acceptance test (quench temperature up to 7.5 K at nominal current). Some complementary quench tests were performed on the spare coil TFC02, with different conditions, especially reduced current (at 75% and 50% of nominal current) and delayed quench detection (holding time of 0.5 s instead of 0.1 s). A numerical model was developed, with SuperMagnet (fortran, CryoSoft) coupling THEA (Thermohydraulic and electric 1-D physics of Cable In Conduit Conductor, CICC) and Flower (Thermohydraulic model of cryogenic network). The measurements are presented and compared to simulation results. The acceptance quench test of TFC02 depicted a maximal helium temperature of 27 K. During complementary quench tests, delayed quench detection induced higher helium temperature of 37 K. At 75% and 50% of nominal current, a so called “smooth” quench occurred. It is characterized by slow quench propagation and low resistive voltage which increase the quench propagation time required before triggering current discharge although it reduces the Joule energy dissipated by the coil.
- 3 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Thermal Hydraulic Analysis of JT-60SA TFC02 Complementary Quench Tests in CTF
In the framework of JT-60SA tokamak commissioning (Japan, 2021), the 20 Toroidal Field Coils (TFC) were tested at the Cold Test Facility (CTF) at CEA-Saclay (France, 2018) and submitted to quench acceptance test (quench temperature up to 7.5 K at nominal current). Some complementary quench tests were performed on the spare coil TFC02, with different conditions, especially reduced current (at 75% and 50% of nominal current) and delayed quench detection (holding time of 0.5 s instead of 0.1 s). A numerical model was developed, with SuperMagnet (fortran, CryoSoft) coupling THEA (Thermohydraulic and electric 1-D physics of Cable In Conduit Conductor, CICC) and Flower (Thermohydraulic model of cryogenic network). The measurements are presented and compared to simulation results. The acceptance quench test of TFC02 depicted a maximal helium temperature of 27 K. During complementary quench tests, delayed quench detection induced higher helium temperature of 37 K. At 75% and 50% of nominal current, a so called “smooth” quench occurred. It is characterized by slow quench propagation and low resistive voltage which increase the quench propagation time required before triggering current discharge although it reduces the Joule energy dissipated by the coil.