GPU accelerated Monte Carlo scoring of positron emitting isotopes produced during proton therapy for PET verification
Open Access
- 12 December 2022
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (24) , 244001
Abstract
Objective. Verification of delivered proton therapy treatments is essential for reaping the many benefits of the modality, with the most widely proposed in vivo verification technique being the imaging of positron emitting isotopes generated in the patient during treatment using positron emission tomography (PET). The purpose of this work is to reduce the computational resources and time required for simulation of patient activation during proton therapy using the GPU accelerated Monte Carlo code FRED, and to validate the predicted activity against the widely used Monte Carlo code GATE. Approach. We implement a continuous scoring approach for the production of positron emitting isotopes within FRED version 5.59.9. We simulate treatment plans delivered to 95 head and neck patients at Centrum Cyklotronowe Bronowice using this GPU implementation, and verify the accuracy using the Monte Carlo toolkit GATE version 9.0. Main results. We report an average reduction in computational time by a factor of 50 when using a local system with 2 GPUs as opposed to a large compute cluster utilising between 200 to 700 CPU threads, enabling simulation of patient activity within an average of 2.9 min as opposed to 146 min. All simulated plans are in good agreement across the two Monte Carlo codes. The two codes agree within a maximum of 0.95 σ on a voxel-by-voxel basis for the prediction of 7 different isotopes across 472 simulated fields delivered to 95 patients, with the average deviation over all fields being 6.4 × 10 −3 σ . Significance. The implementation of activation calculations in the GPU accelerated Monte Carlo code FRED provides fast and reliable simulation of patient activation following proton therapy, allowing for research and development of clinical applications of range verification for this treatment modality using PET to proceed at a rapid pace.Keywords
Funding Information
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (CRSII5189969)
- National Center for Research and Development (LIDER/26/0157/L-8/16/NCBR/2017)
This publication has 43 references indexed in Scilit:
- PET-based dose delivery verification in proton therapy: a GATE based simulation study of five PET system designs in clinical conditionsPhysics in Medicine & Biology, 2013
- TOPAS: An innovative proton Monte Carlo platform for research and clinical applicationsMedical Physics, 2012
- Range uncertainties in proton therapy and the role of Monte Carlo simulationsPhysics in Medicine & Biology, 2012
- A Monte Carlo pencil beam scanning model for proton treatment plan simulation using GATE/GEANT4Physics in Medicine & Biology, 2011
- Experimental verification of IMPT treatment plans in an anthropomorphic phantom in the presence of delivery uncertaintiesPhysics in Medicine & Biology, 2011
- Monitoring proton radiation therapy with in-room PET imagingPhysics in Medicine & Biology, 2011
- Patient Study of In Vivo Verification of Beam Delivery and Range, Using Positron Emission Tomography and Computed Tomography Imaging After Proton TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Clinical CT-based calculations of dose and positron emitter distributions in proton therapy using the FLUKA Monte Carlo codePhysics in Medicine & Biology, 2007
- A filtering approach based on Gaussian–powerlaw convolutions for local PET verification of proton radiotherapyPhysics in Medicine & Biology, 2006
- The calibration of CT Hounsfield units for radiotherapy treatment planningPhysics in Medicine & Biology, 1996