Christoph Hassa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christoph Hassa has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Johannes Heinze
Institute of Biochemistry and Biology, Biodiversity Research and Systematic Botany, University of Potsdam, Potsdam, Germany
4 shared publications - Guido Stockhausen
DLR—German Aerospace Center, Institute of Propulsion Technology, Linder Hoehe, Cologne 51147, Germany
3 shared publications - Christian Willert
DLR Institute of Propulsion Technology, German Aerospace Center, Köln, Germany
2 shared publications - Imon Bagchi
Rolls-Royce Deutschland Ltd & Co KG, Eschenweg 11, Dahlewitz, Blankenfelde-Mahlow 15827, Germany
2 shared publications - Michael Schroll
German Aerospace Center (DLR), Cologne, Germany
2 shared publications - Ulrich Doll
German Aerospace Center, Cologne, Germany
2 shared publications
Latest Publications
- Open Access
Influence of Fluidic Control in a Staged Lean Jet Engine Burner on Combustor Performance
To improve the turn-down ratio of a lean combustor, which has the greatest potential for reducing NOx emissions from jet engines, fuel staging is commonly employed. To further extend the stable operation range, air staging with a fluidic element is also considered. The influence of fluidic control on combustion was analyzed to better understand fluidic element-burner interactions. The pressure loss of each fluidic element was determined by measuring the pressure at the element exits. The effect of fluidic control on the atomization, fuel distribution, and flow field was investigated using optical, noninvasive techniques. The combustion performance of the burner with the fluidic element was evaluated using exhaust gas analyses. The pressure losses of the swirlers and fuel mixers were varied depending on the bleed air from the fluidic element. Under the idle condition, the reduction of pressure loss in the pilot fuel mixer resulted in inferior atomization due to the reduced gas velocity around the fuel film, which had a positive effect on lean blowout. Under the cruise condition and the staged mode, the reduction of the pilot air flow increased the equivalence ratio of the lean pilot stage and resulted in higher combustion efficiency.
Open AccessInfluence of Fluidic Control in a Staged Lean Jet Engine Burner on Combustor Performance
To improve the turn-down ratio of a lean combustor, which has the greatest potential for reducing NOx emissions from jet engines, fuel staging is commonly employed. To further extend the stable operation range, air staging with a fluidic element is also considered. The influence of fluidic control on combustion was analyzed to better understand fluidic element-burner interactions. The pressure loss of each fluidic element was determined by measuring the pressure at the element exits. The effect of fluidic control on the atomization, fuel distribution, and flow field was investigated using optical, noninvasive techniques. The combustion performance of the burner with the fluidic element was evaluated using exhaust gas analyses. The pressure losses of the swirlers and fuel mixers were varied depending on the bleed air from the fluidic element. Under the idle condition, the reduction of pressure loss in the pilot fuel mixer resulted in inferior atomization due to the reduced gas velocity around the fuel film, which had a positive effect on lean blowout. Under the cruise condition and the staged mode, the reduction of the pilot air flow increased the equivalence ratio of the lean pilot stage and resulted in higher combustion efficiency.
- 13 February 2018
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 140 (6)
Investigation of Flame Structure and Soot Formation in a Single Sector Model Combustor Using Experiments and Numerical Simulations Based on the Large Eddy Simulation/Conditional Moment Closure Approach
In this work, a single sector lean burn model combustor operating in pilot only mode has been investigated using both experiments and computations with the main objective of analyzing the flame structure and soot formation at conditions relevant to aero-engine applications. Numerical simulations were performed using the large eddy simulation (LES) approach and the conditional moment closure (CMC) combustion model with detailed chemistry and a two-equation model for soot. The CMC model is based on the time-resolved solution of the local flame structure and allows to directly take into account the phenomena associated to molecular mixing and turbulent transport, which are of great importance for the prediction of emissions. The rig investigated in this work, called big optical single sector rig, allows to test real scale lean burn injectors. Experiments, performed at elevated pressure and temperature, corresponding to engine conditions at part load, include planar laser-induced fluorescence of OH (OH-PLIF) and phase Doppler anemometry (PDA) and have been complemented with new laser-induced incandescence (LII) measurements for soot location. The wide range of measurements available allows a comprehensive analysis of the primary combustion region and can be exploited to further assess and validate the LES/CMC approach to capture the flame behavior at engine conditions. It is shown that the LES/CMC approach is able to predict the main characteristics of the flame with a good agreement with the experiment in terms of flame shape, spray characteristics and soot location. Finite-rate chemistry effects appear to be very important in the region close to the injection location leading to the lift-off of the flame. Low levels of soot are observed immediately downstream of the injector exit, where a high amount of vaporized fuel is still present. Further downstream, the fuel vapor disappears quite quickly and an extended region characterized by the presence of pyrolysis products and soot precursors is observed. The strong production of soot precursors together with high soot surface growth rates lead to high values of soot volume fraction in locations consistent with the experiment. Soot oxidation is also very important in the downstream region resulting in a decrease of the soot level at the combustor exit. The results show a very promising capability of the LES/CMC approach to capture the main characteristics of the flame, soot formation, and location at engine relevant conditions. More advanced soot models will be considered in future work in order to improve the quantitative prediction of the soot level.
- 13 February 2018
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 140 (6)
Investigation of Flame Structure and Soot Formation in a Single Sector Model Combustor Using Experiments and Numerical Simulations Based on the Large Eddy Simulation/Conditional Moment Closure Approach
In this work, a single sector lean burn model combustor operating in pilot only mode has been investigated using both experiments and computations with the main objective of analyzing the flame structure and soot formation at conditions relevant to aero-engine applications. Numerical simulations were performed using the large eddy simulation (LES) approach and the conditional moment closure (CMC) combustion model with detailed chemistry and a two-equation model for soot. The CMC model is based on the time-resolved solution of the local flame structure and allows to directly take into account the phenomena associated to molecular mixing and turbulent transport, which are of great importance for the prediction of emissions. The rig investigated in this work, called big optical single sector rig, allows to test real scale lean burn injectors. Experiments, performed at elevated pressure and temperature, corresponding to engine conditions at part load, include planar laser-induced fluorescence of OH (OH-PLIF) and phase Doppler anemometry (PDA) and have been complemented with new laser-induced incandescence (LII) measurements for soot location. The wide range of measurements available allows a comprehensive analysis of the primary combustion region and can be exploited to further assess and validate the LES/CMC approach to capture the flame behavior at engine conditions. It is shown that the LES/CMC approach is able to predict the main characteristics of the flame with a good agreement with the experiment in terms of flame shape, spray characteristics and soot location. Finite-rate chemistry effects appear to be very important in the region close to the injection location leading to the lift-off of the flame. Low levels of soot are observed immediately downstream of the injector exit, where a high amount of vaporized fuel is still present. Further downstream, the fuel vapor disappears quite quickly and an extended region characterized by the presence of pyrolysis products and soot precursors is observed. The strong production of soot precursors together with high soot surface growth rates lead to high values of soot volume fraction in locations consistent with the experiment. Soot oxidation is also very important in the downstream region resulting in a decrease of the soot level at the combustor exit. The results show a very promising capability of the LES/CMC approach to capture the main characteristics of the flame, soot formation, and location at engine relevant conditions. More advanced soot models will be considered in future work in order to improve the quantitative prediction of the soot level.
- 20 September 2016
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 139 (2) , 021507
Temperature Measurements at the Outlet of a Lean Burn Single-Sector Combustor by Laser Optical Methods
High overall pressure ratio (OPR) engine cycles for reduced NOx emissions will generate new aggravated requirements and boundary conditions by implementing low emission combustion technologies into advanced engine architectures. Lean burn combustion systems will have a significant impact on the temperature and velocity traverse at the combustor exit. With the transition to high-pressure engines, it is essential to fully understand and determine the high energetic interface between combustor and turbine to avoid excessive cooling. Spatially resolved temperatures were measured at different operating conditions using planar laser-induced fluorescence of OH (OH-PLIF) and filtered Rayleigh scattering (FRS), the latter being used in a combustor environment for the first time. Apart from a conventional signal detection arrangement, FRS was also applied with an endoscope for signal collection, to assess its feasibility for future application in a full annular combustor with restricted optical access. Both techniques are complementary in several respects, which justified their combined application. OH-PLIF allows instantaneous measurements and therefore enables local temperature statistics, but is limited to relatively high temperatures. On the other hand, FRS can also be applied at low temperatures, which makes it particularly attractive for measurements in cooling layers. However, FRS requires long sampling times and therefore can only provide temporal averages. When applied in combination, the accuracy of both techniques could be improved by each method helping to overcome the other's shortcomings.
- 20 September 2016
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 139 (2) , 021507
Temperature Measurements at the Outlet of a Lean Burn Single-Sector Combustor by Laser Optical Methods
High overall pressure ratio (OPR) engine cycles for reduced NOx emissions will generate new aggravated requirements and boundary conditions by implementing low emission combustion technologies into advanced engine architectures. Lean burn combustion systems will have a significant impact on the temperature and velocity traverse at the combustor exit. With the transition to high-pressure engines, it is essential to fully understand and determine the high energetic interface between combustor and turbine to avoid excessive cooling. Spatially resolved temperatures were measured at different operating conditions using planar laser-induced fluorescence of OH (OH-PLIF) and filtered Rayleigh scattering (FRS), the latter being used in a combustor environment for the first time. Apart from a conventional signal detection arrangement, FRS was also applied with an endoscope for signal collection, to assess its feasibility for future application in a full annular combustor with restricted optical access. Both techniques are complementary in several respects, which justified their combined application. OH-PLIF allows instantaneous measurements and therefore enables local temperature statistics, but is limited to relatively high temperatures. On the other hand, FRS can also be applied at low temperatures, which makes it particularly attractive for measurements in cooling layers. However, FRS requires long sampling times and therefore can only provide temporal averages. When applied in combination, the accuracy of both techniques could be improved by each method helping to overcome the other's shortcomings.
- 16 August 2016
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 139 (1) , 011503
Flow Field Characterization at the Outlet of a Lean Burn Single-Sector Combustor by Laser-Optical Methods
High overall pressure ratio (OPR) engine cycles for reduced NOx emissions will generate new aggravated requirements and boundary conditions by implementing low emission combustion technologies into advanced engine architectures. Lean burn combustion systems will have a significant impact on the temperature and velocity traverse at the combustor exit. Lean burn fuel injectors dominate the combustor exit conditions. This is due to the fact that they pass a majority of the total combustor flow, and to the lack of mixing jets like in a conventional combustor. With the transition to high-pressure engines, it is essential to fully understand and determine the high energetic interface between combustor and turbine to avoid excessive cooling. Velocity distributions and their fluctuations at the combustor exit for lean burn are of special interest as they can influence the efficiency and capacity of the turbine. A lean burn single-sector combustor was designed and built at DLR, providing optical access to its rectangular exit section. The sector was operated with a fuel-staged lean burn injector. Measurements were performed under idle and cruise operating conditions. Two velocity measurement techniques were used in the demanding environment of highly luminous flames under elevated pressures: particle image velocimetry (PIV) and filtered Rayleigh scattering (FRS). The latter was used for the first time in an aero-engine combustor environment. In addition to a conventional signal detection arrangement, FRS was also applied with an endoscope for signal collection, to assess its practicality for a potential future application in a full annular combustor with restricted optical access.
- 16 August 2016
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 139 (1) , 011503
Flow Field Characterization at the Outlet of a Lean Burn Single-Sector Combustor by Laser-Optical Methods
High overall pressure ratio (OPR) engine cycles for reduced NOx emissions will generate new aggravated requirements and boundary conditions by implementing low emission combustion technologies into advanced engine architectures. Lean burn combustion systems will have a significant impact on the temperature and velocity traverse at the combustor exit. Lean burn fuel injectors dominate the combustor exit conditions. This is due to the fact that they pass a majority of the total combustor flow, and to the lack of mixing jets like in a conventional combustor. With the transition to high-pressure engines, it is essential to fully understand and determine the high energetic interface between combustor and turbine to avoid excessive cooling. Velocity distributions and their fluctuations at the combustor exit for lean burn are of special interest as they can influence the efficiency and capacity of the turbine. A lean burn single-sector combustor was designed and built at DLR, providing optical access to its rectangular exit section. The sector was operated with a fuel-staged lean burn injector. Measurements were performed under idle and cruise operating conditions. Two velocity measurement techniques were used in the demanding environment of highly luminous flames under elevated pressures: particle image velocimetry (PIV) and filtered Rayleigh scattering (FRS). The latter was used for the first time in an aero-engine combustor environment. In addition to a conventional signal detection arrangement, FRS was also applied with an endoscope for signal collection, to assess its practicality for a potential future application in a full annular combustor with restricted optical access.
- Open Access
- 1 December 2011
- Published by SAGE Publications in International Journal of Spray and Combustion Dynamics
- Vol. 3 (4) , 273-284
Self-Exited Oscillation in a Combustion Chamber Driven by Phase Change in the Liquid Fuel Feed System
A new mechanism for the generation of a self-exited oscillation of combustion in a generic combustion chamber typical for aeroengine combustors is described. The cause of the oscillation is the phase change from liquid to vapour which happens when the preheat temperature of the air flowing through the burner exceeds the boiling temperature at the operating pressure and the fuel flow is so low that heat transfer to the liquid fuel causes evaporation within the fuel channels of the burner. Liquid fuel and vapour alternatively enter the airstream of the burner. This leads to an unstable situation for the flame. Measurements of chemiluminescence and liquid fuel show nearly complete extinction and re-ignition for the limit cycle. Prevention of the oscillation is possible by better thermal management of the fuel path.
- 1 December 2011
- Published by SAGE Publications in International Journal of Spray and Combustion Dynamics
- Vol. 3 (4) , 273-284
Open AccessSelf-Exited Oscillation in a Combustion Chamber Driven by Phase Change in the Liquid Fuel Feed System
A new mechanism for the generation of a self-exited oscillation of combustion in a generic combustion chamber typical for aeroengine combustors is described. The cause of the oscillation is the phase change from liquid to vapour which happens when the preheat temperature of the air flowing through the burner exceeds the boiling temperature at the operating pressure and the fuel flow is so low that heat transfer to the liquid fuel causes evaporation within the fuel channels of the burner. Liquid fuel and vapour alternatively enter the airstream of the burner. This leads to an unstable situation for the flame. Measurements of chemiluminescence and liquid fuel show nearly complete extinction and re-ignition for the limit cycle. Prevention of the oscillation is possible by better thermal management of the fuel path.
- 1 January 2006
- Published by ASME International
- Vol. 2006, 173-182
Nonintrusive Flowfield, Temperature and Species Measurements on a Generic Aeroengine Combustor at Elevated Pressures
A generic combustor was built, that gives wide optical access at higher pressure and shares typical features with aero engine combustors. A comprehensive data set for validation of RANS and LES codes was generated at isothermal as well as combusting conditions at 2 and 10 bars with 650 K preheat using natural gas as fuel. The velocity field was measured using LDA (Laser Doppler Anemometry) and DGV (Doppler Global Velocimetry) as well as PIV (Particle Image Velocimetry). Temperature data were acquired using CARS (Coherent Anti stokes Raman Scattering) and SRS (Spontaneous Raman Scattering). Major species concentrations as well as the mixture fraction in the primary zone of the combustor were also measured using SRS. Mean and RMS values of the temperature measured by CARS in the secondary zone illustrate the influence of the jet impingement on the unsteady mixing of the jets with the swirling primary air.
- 1 January 2006
- Published by ASME International
- Vol. 2006, 173-182
Nonintrusive Flowfield, Temperature and Species Measurements on a Generic Aeroengine Combustor at Elevated Pressures
A generic combustor was built, that gives wide optical access at higher pressure and shares typical features with aero engine combustors. A comprehensive data set for validation of RANS and LES codes was generated at isothermal as well as combusting conditions at 2 and 10 bars with 650 K preheat using natural gas as fuel. The velocity field was measured using LDA (Laser Doppler Anemometry) and DGV (Doppler Global Velocimetry) as well as PIV (Particle Image Velocimetry). Temperature data were acquired using CARS (Coherent Anti stokes Raman Scattering) and SRS (Spontaneous Raman Scattering). Major species concentrations as well as the mixture fraction in the primary zone of the combustor were also measured using SRS. Mean and RMS values of the temperature measured by CARS in the secondary zone illustrate the influence of the jet impingement on the unsteady mixing of the jets with the swirling primary air.
- 1 January 2002
- Published by ASME International
- p. 267-274
Investigation of the Response of an Air Blast Atomiser Combustion Chamber Configuration on Forced Modulation of Air Feed at Realistic Operating Conditions
DLR investigated forced combustion oscillations of two liquid fuel burners in a research combustion chamber at elevated pressures simulating idle conditions of aircraft engine combustors. The work was performed in collaboration with MTU Munich. An existing combustion chamber with optical access, capable to operate up to 20 bar, was upgraded with an air flow pulsator, that bypasses air from the combustor plenum to the exhaust with a sinusoidal massflow variation up to 700 Hz. Pressure transducers in the plenum and the flame tube monitored the forced disturbances. A photomultiplier recorded the OH* chemiluminescence of the flame. For the agreed operating conditions frequency scans of these values were registered. Additionally images of the OH* chemiluminescence were taken at selected frequencies and evaluated in a statistical manner, to separate turbulent and periodic behaviour. From the analysis of the pressure data, it can be concluded, that serious thermo-acoustic feedback was not observed for both burners. However burner 2 with the flame detached from the wall exhibited a higher fluctuation level as burner 1 with the wall attached flame. A resonant behaviour was observed near the characteristic frequency of the sound room comprised of plenum, flame tube and burner nozzle as connecting passage. The chemiluminescence images show different modes of spatial fluctuation for the burners and for burner 2 they also vary with the operating condition.
- 1 January 2002
- Published by ASME International
- p. 267-274
Investigation of the Response of an Air Blast Atomiser Combustion Chamber Configuration on Forced Modulation of Air Feed at Realistic Operating Conditions
DLR investigated forced combustion oscillations of two liquid fuel burners in a research combustion chamber at elevated pressures simulating idle conditions of aircraft engine combustors. The work was performed in collaboration with MTU Munich. An existing combustion chamber with optical access, capable to operate up to 20 bar, was upgraded with an air flow pulsator, that bypasses air from the combustor plenum to the exhaust with a sinusoidal massflow variation up to 700 Hz. Pressure transducers in the plenum and the flame tube monitored the forced disturbances. A photomultiplier recorded the OH* chemiluminescence of the flame. For the agreed operating conditions frequency scans of these values were registered. Additionally images of the OH* chemiluminescence were taken at selected frequencies and evaluated in a statistical manner, to separate turbulent and periodic behaviour. From the analysis of the pressure data, it can be concluded, that serious thermo-acoustic feedback was not observed for both burners. However burner 2 with the flame detached from the wall exhibited a higher fluctuation level as burner 1 with the wall attached flame. A resonant behaviour was observed near the characteristic frequency of the sound room comprised of plenum, flame tube and burner nozzle as connecting passage. The chemiluminescence images show different modes of spatial fluctuation for the burners and for burner 2 they also vary with the operating condition.