Nobukazu Tanaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nobukazu Tanaka has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Junji Morishita
Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, Japan
6 shared publicationsMasafumi Ohki
Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, Japan
6 shared publicationsFukai Toyofuku
Kyushu University
4 shared publicationsKentaro Naka
Kyushu University
4 shared publicationsYoshiharu Higashida
Kyushu University
4 shared publications- Hidetaka Arimura
Division of Medical Quantum Science, Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka 812-8582, Japan
2 shared publications
Latest Publications
- Open Access
- 13 May 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (10) , 5203
Proper Management of the Clinical Exposure Index Based on Body Thickness Using Dose Optimization Tools in Digital Chest Radiography: A Phantom Study
In radiography, the exposure index (EI), as per the International Electrotechnical Commission standard, depends on the incident beam quality and exposure dose to the digital radiography system. Today automatic exposure control (AEC) systems are commonly employed to obtain the optimal image quality. An AEC system can maintain a constant incident exposure dose on the image receptor regardless of the patient thickness. In this study, we investigated the relationship between body thickness, entrance surface dose (ESD), EI, and the exposure indicator (S value) with the aim of using EI as the dose optimization tool in digital chest radiography (posterior–anterior and lateral projection). The exposure condition from the Korean national survey for determining diagnostic reference levels and two digital radiography systems (photostimulable phosphor plate and indirect flat panel detector) were used. As a result, ESD increased as the phantom became thicker with constant exposure indicator, which indicates similar settings to an AEC system, but the EI indicated comparatively constant values without following the tendency of ESD. Therefore, body thickness should be considered under the AEC system for introducing EI as the dose optimization tool in digital chest radiography.
- 13 May 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (10) , 5203
Open AccessProper Management of the Clinical Exposure Index Based on Body Thickness Using Dose Optimization Tools in Digital Chest Radiography: A Phantom Study
In radiography, the exposure index (EI), as per the International Electrotechnical Commission standard, depends on the incident beam quality and exposure dose to the digital radiography system. Today automatic exposure control (AEC) systems are commonly employed to obtain the optimal image quality. An AEC system can maintain a constant incident exposure dose on the image receptor regardless of the patient thickness. In this study, we investigated the relationship between body thickness, entrance surface dose (ESD), EI, and the exposure indicator (S value) with the aim of using EI as the dose optimization tool in digital chest radiography (posterior–anterior and lateral projection). The exposure condition from the Korean national survey for determining diagnostic reference levels and two digital radiography systems (photostimulable phosphor plate and indirect flat panel detector) were used. As a result, ESD increased as the phantom became thicker with constant exposure indicator, which indicates similar settings to an AEC system, but the EI indicated comparatively constant values without following the tendency of ESD. Therefore, body thickness should be considered under the AEC system for introducing EI as the dose optimization tool in digital chest radiography.
- 4 June 2013
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 6 (2) , 474-479
Effect of readout direction in the edge profile on the modulation transfer function of computed radiographic systems by use of the edge method
We investigated the effect of the readout direction of the edge profile obtained by the edge method on the presampled modulation transfer function (MTF) in various computed radiographic (CR) systems. There were no differences in the MTFs derived from two edge profiles in the sub-scanning direction of four CR systems used in this study. On the other hand, the MTFs measured at a readout direction from the low (edge) to the high (direct exposure) exposure region were higher than those measured at a readout direction from the high to the low exposure region in the laser-beam scanning direction for three of the four CR systems. Although this phenomenon depends on the CR system, it is important to understand and indicate both MTFs at the two edge profiles in the laser-beam scanning direction for accurate assessment of the resolution property.
- 4 June 2013
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 6 (2) , 474-479
Effect of readout direction in the edge profile on the modulation transfer function of computed radiographic systems by use of the edge method
We investigated the effect of the readout direction of the edge profile obtained by the edge method on the presampled modulation transfer function (MTF) in various computed radiographic (CR) systems. There were no differences in the MTFs derived from two edge profiles in the sub-scanning direction of four CR systems used in this study. On the other hand, the MTFs measured at a readout direction from the low (edge) to the high (direct exposure) exposure region were higher than those measured at a readout direction from the high to the low exposure region in the laser-beam scanning direction for three of the four CR systems. Although this phenomenon depends on the CR system, it is important to understand and indicate both MTFs at the two edge profiles in the laser-beam scanning direction for accurate assessment of the resolution property.
- 8 August 2012
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 6 (1) , 54-60
Investigation of optimum anti-scatter grid selection for digital radiography: physical imaging properties and detectability of low-contrast signals
Our aim in this study was to evaluate the effect of the grid variations on the imaging performance for a computed radiographic system under identical exposure condition. Digital radiographies using a 20-cm Lucite phantom were performed without grid and with grid ratios of 5:1, 8:1, 10:1, 12:1, and 14:1. The scatter fraction, the incident dose to the image receptor, the Wiener spectrum (WS), and the noise-equivalent quanta (NEQ) were measured. Visibility of low-contrast signals was evaluated using a contrast-detail phantom. The scatter fractions decreased considerably with an increase in the grid ratio. On the other hand, the WSs were increased (the noise property deteriorated) as the grid ratio increased due to a decreased incident dose to the image receptor under the identical exposure condition. The NEQs were improved as the grid ratio increased. The high grid ratios provided higher low-contrast detectability compared to the low grid ratios. Our results indicated that the removal of scattered radiation was very effective in improvement of the NEQ in the digital system under the identical exposure condition.
- 8 August 2012
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 6 (1) , 54-60
Investigation of optimum anti-scatter grid selection for digital radiography: physical imaging properties and detectability of low-contrast signals
Our aim in this study was to evaluate the effect of the grid variations on the imaging performance for a computed radiographic system under identical exposure condition. Digital radiographies using a 20-cm Lucite phantom were performed without grid and with grid ratios of 5:1, 8:1, 10:1, 12:1, and 14:1. The scatter fraction, the incident dose to the image receptor, the Wiener spectrum (WS), and the noise-equivalent quanta (NEQ) were measured. Visibility of low-contrast signals was evaluated using a contrast-detail phantom. The scatter fractions decreased considerably with an increase in the grid ratio. On the other hand, the WSs were increased (the noise property deteriorated) as the grid ratio increased due to a decreased incident dose to the image receptor under the identical exposure condition. The NEQs were improved as the grid ratio increased. The high grid ratios provided higher low-contrast detectability compared to the low grid ratios. Our results indicated that the removal of scattered radiation was very effective in improvement of the NEQ in the digital system under the identical exposure condition.
- 18 March 2011
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 4 (2) , 156-163
Digital magnification mammography with matched incident exposure: physical imaging properties and detectability of simulated microcalcifications
Our purpose was to evaluate the usefulness of digital magnification mammography with matched incident exposure by investigating the physical imaging properties and doing an observer performance test. A computed radiography system and a mammographic unit were used in this study. Contact and magnification radiographies of 1.2–1.8 in combination with focal spot sizes of 0.1 mm without grid and 0.3 mm with grid were performed. Physical imaging properties, namely, scatter fraction, total modulation transfer function (MTF) including the presampled MTF and the MTF of focal spot size, and Wiener spectrum (WS), were measured. Detail visibility was evaluated by use of free-response receiver operating characteristic analysis of the detectability of simulated microcalcifications. Scatter fractions decreased considerably as the magnification factor increased without grid technique. In the grid technique, scatter fractions for all magnification techniques were comparable. The total MTFs of magnification techniques with a focal spot size of 0.1 mm improved significantly compared with the conventional contact technique. However, the improvement of the total MTFs of magnification techniques with the combination of 0.3 mm focal spot size was small. The WSs degraded with an increase of the magnification factor compared with the contact technique due to the maintained exposure incident on the object. The observer performance test indicated that the 1.8 magnification technique with the 0.1 mm focal spot size provided higher detectability than did the contact technique. Digital magnification mammography under the same incident exposure conditions improved the detectability of microcalcifications.
- 18 March 2011
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 4 (2) , 156-163
Digital magnification mammography with matched incident exposure: physical imaging properties and detectability of simulated microcalcifications
Our purpose was to evaluate the usefulness of digital magnification mammography with matched incident exposure by investigating the physical imaging properties and doing an observer performance test. A computed radiography system and a mammographic unit were used in this study. Contact and magnification radiographies of 1.2–1.8 in combination with focal spot sizes of 0.1 mm without grid and 0.3 mm with grid were performed. Physical imaging properties, namely, scatter fraction, total modulation transfer function (MTF) including the presampled MTF and the MTF of focal spot size, and Wiener spectrum (WS), were measured. Detail visibility was evaluated by use of free-response receiver operating characteristic analysis of the detectability of simulated microcalcifications. Scatter fractions decreased considerably as the magnification factor increased without grid technique. In the grid technique, scatter fractions for all magnification techniques were comparable. The total MTFs of magnification techniques with a focal spot size of 0.1 mm improved significantly compared with the conventional contact technique. However, the improvement of the total MTFs of magnification techniques with the combination of 0.3 mm focal spot size was small. The WSs degraded with an increase of the magnification factor compared with the contact technique due to the maintained exposure incident on the object. The observer performance test indicated that the 1.8 magnification technique with the 0.1 mm focal spot size provided higher detectability than did the contact technique. Digital magnification mammography under the same incident exposure conditions improved the detectability of microcalcifications.
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 149-151
Investigation of Optimum Grid for Digital Radiography
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 149-151
Investigation of Optimum Grid for Digital Radiography
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 64-66
Imaging Properties of Digital Magnification Mammography
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 64-66
Imaging Properties of Digital Magnification Mammography