Bernard Laskowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bernard Laskowski has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Douglas Brown
Analatom, Inc., 562 E. Weddell Dr. Suite 4, Sunnyvale, CA 94089-2108, USA
4 shared publications - Duane Darr
Analatom, Inc., 562 E. Weddell Dr. Suite 4, Sunnyvale, CA 94089-2108, USA
4 shared publications - Jefferey Morse
Analatom, Inc
3 shared publications - Richard J. Connolly
Analatom, Inc., 3210 Scott Blvd., Santa Clara, CA 95054, USA
2 shared publications Aaron Corder
Missile Defense Agency
1 shared publicationAjit Mal
University of California
1 shared publication
Latest Publications
- 30 November 2014
- Published by Springer Nature
- p. 673-685
Corrosion Detection on Buried Transmission Pipelines with Micro-Linear Polarization Resistance Sensors
- 30 November 2014
- Published by Springer Nature
- p. 673-685
Corrosion Detection on Buried Transmission Pipelines with Micro-Linear Polarization Resistance Sensors
- Open Access
- 29 September 2014
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 6 (1)
Electrochemical Impedance Spectroscopy for Coating Evaluation using a Micro Sensor
This paper discusses a micro-linear polarization resistance (μLPR) sensor modified to perform coating evaluation by means of electrochemical impedance spectroscopy (EIS). A circuit model is used with the EIS data to measure solution resistance, pore resistance, charge transfer resistance, intact coating capacitance, and double layer capacitance. These measurements allow the end user to monitor degradation of protective coatings in real-time, through non-destructive means. This is demonstrated through an accelerated aging test using a coated metal plate with a modified μLPR sensor. A metal panel made from aluminum alloy 7075-T6 was coated with 2 mils of an epoxy-based polymer coating and 2 mils of high solids polyurethane. The sensor was adhered to the face of the coated panel in a manner that allowed the electrolyte solution consisting of 3.5% NaCl to flow between the sensor and the coated surface of the panel. EIS measurements were acquired every hour for a total of 35 hours and at the conclusion of the test, changes in key parameters within the circuit model identified the initial time and mechanism of coating degradation, in this case, delamination
- 29 September 2014
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 6 (1)
Open AccessElectrochemical Impedance Spectroscopy for Coating Evaluation using a Micro Sensor
This paper discusses a micro-linear polarization resistance (μLPR) sensor modified to perform coating evaluation by means of electrochemical impedance spectroscopy (EIS). A circuit model is used with the EIS data to measure solution resistance, pore resistance, charge transfer resistance, intact coating capacitance, and double layer capacitance. These measurements allow the end user to monitor degradation of protective coatings in real-time, through non-destructive means. This is demonstrated through an accelerated aging test using a coated metal plate with a modified μLPR sensor. A metal panel made from aluminum alloy 7075-T6 was coated with 2 mils of an epoxy-based polymer coating and 2 mils of high solids polyurethane. The sensor was adhered to the face of the coated panel in a manner that allowed the electrolyte solution consisting of 3.5% NaCl to flow between the sensor and the coated surface of the panel. EIS measurements were acquired every hour for a total of 35 hours and at the conclusion of the test, changes in key parameters within the circuit model identified the initial time and mechanism of coating degradation, in this case, delamination
- Open Access
- 8 July 2014
- Published by PHM Society in Phm Society European Conference
- Vol. 2 (1)
Linear Polarization Resistance Sensor Using the Structure as aWorking Electrode
A direct method of measuring corrosion on a structure using a micro-linear polarization resistance (mLPR) sensor is presented. The sensor includes three electrodes, where each electrode is fabricated on a flexible substrate to create a circuit consisting of gold-plated copper. The first two electrodes, or the counter and reference electrodes, are configured in an interdigitated fashion with a separation distance of 8mil. The flex cable contains a porous membrane between the pair of electrodes and the structure. A third electrode, or the working electrode makes electrical contact to the structure through a 1mil thick electrically conductive transfer tape placed between the electrode and structure. The reference and counter electrodes are electrically isolated from the working electrode and physically separated from the surface of the structure by 1mil. The flex cable can be attached to the structure through the use of adhesives or in the case of placement in a butt joint or lap joint configuration, by the joint itself. Corrosion is computed from known physical constants, by measuring the polarization resistance between the electrolytic solution and the structure. A controlled experiment using the ASTM G85 Annex 5 standard verifies the precision and accuracy of sensor measurements by comparing the estimated mass loss with witness coupons.
- 8 July 2014
- Published by PHM Society in Phm Society European Conference
- Vol. 2 (1)
Open AccessLinear Polarization Resistance Sensor Using the Structure as aWorking Electrode
A direct method of measuring corrosion on a structure using a micro-linear polarization resistance (mLPR) sensor is presented. The sensor includes three electrodes, where each electrode is fabricated on a flexible substrate to create a circuit consisting of gold-plated copper. The first two electrodes, or the counter and reference electrodes, are configured in an interdigitated fashion with a separation distance of 8mil. The flex cable contains a porous membrane between the pair of electrodes and the structure. A third electrode, or the working electrode makes electrical contact to the structure through a 1mil thick electrically conductive transfer tape placed between the electrode and structure. The reference and counter electrodes are electrically isolated from the working electrode and physically separated from the surface of the structure by 1mil. The flex cable can be attached to the structure through the use of adhesives or in the case of placement in a butt joint or lap joint configuration, by the joint itself. Corrosion is computed from known physical constants, by measuring the polarization resistance between the electrolytic solution and the structure. A controlled experiment using the ASTM G85 Annex 5 standard verifies the precision and accuracy of sensor measurements by comparing the estimated mass loss with witness coupons.
- Open Access
- 23 September 2012
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 4 (1)
Real-Time Corrosion Monitoring of Aircraft Structures with Prognostic Applications
This paper presents the theory and experimental validation of a Structural Health Management (SHM) system for monitoring corrosion. Corrosion measurements are acquired using a micro-sized Linear Polarization Resistance (μLPR) sensor. The μLPR sensor is based on conventional macro-sized Linear Polarization Resistance (LPR) sensors with the additional benefit of a reduced form factor making it a viable and economical candidate for remote corrosion monitoring of high value structures, such as buildings, bridges, or aircraft.A series of experiments were conducted to evaluate the μLPR sensor for AA 7075-T6, a common alloy used in aircraft structures. Twelve corrosion coupons were placed alongside twenty-four μLPR sensors in a series of accelerated tests. LPR measurements were sampled once per minute and converted to a corrosion rate using the algorithms presented in this paper. At the end of the experiment, pit-depth due to corrosion was computed from each μLPR sensor and compared with the control coupons.The paper concludes with a feasibility study for the μLPR sensor in prognostic applications. Simultaneous evaluation of twenty-four μLPR sensors provided a stochastic data set appropriate for prognostics. RUL estimates were computed a-posteriori for three separate failure thresholds. The results demonstrate the effectiveness of the sensor as an efficient and practical approach to measuring pit-depth for aircraft structures, such as AA 7075-T6, and provide feasibility for its use in prognostic applications.
- 23 September 2012
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 4 (1)
Open AccessReal-Time Corrosion Monitoring of Aircraft Structures with Prognostic Applications
This paper presents the theory and experimental validation of a Structural Health Management (SHM) system for monitoring corrosion. Corrosion measurements are acquired using a micro-sized Linear Polarization Resistance (μLPR) sensor. The μLPR sensor is based on conventional macro-sized Linear Polarization Resistance (LPR) sensors with the additional benefit of a reduced form factor making it a viable and economical candidate for remote corrosion monitoring of high value structures, such as buildings, bridges, or aircraft.A series of experiments were conducted to evaluate the μLPR sensor for AA 7075-T6, a common alloy used in aircraft structures. Twelve corrosion coupons were placed alongside twenty-four μLPR sensors in a series of accelerated tests. LPR measurements were sampled once per minute and converted to a corrosion rate using the algorithms presented in this paper. At the end of the experiment, pit-depth due to corrosion was computed from each μLPR sensor and compared with the control coupons.The paper concludes with a feasibility study for the μLPR sensor in prognostic applications. Simultaneous evaluation of twenty-four μLPR sensors provided a stochastic data set appropriate for prognostics. RUL estimates were computed a-posteriori for three separate failure thresholds. The results demonstrate the effectiveness of the sensor as an efficient and practical approach to measuring pit-depth for aircraft structures, such as AA 7075-T6, and provide feasibility for its use in prognostic applications.
- Open Access
- 3 July 2012
- Published by PHM Society in Phm Society European Conference
- Vol. 1 (1)
Theoretical and Experimental Evaluation of a Real-Time Corrosion Monitoring System for Measuring Pitting in Aircraft Structures
This paper presents the theory and experimental validation of Analatom’s Structural Health Management (SHM) system for monitoring corrosion. Corrosion measurements are acquired using a micro-sized Linear Polarization Resistance (uLPR) sensor. The uLPR sensor is based on conventional macrosized Linear Polarization Resistance (LPR) sensors with the additional benefit of a reduced form factor making it a viable and economical candidate for remote corrosion monitoring of high value structures, such as buildings, bridges, or aircraft. A series of experiments were conducted to evaluate the uLPR sensor for AA 7075-T6. Test coupons were placed alongside Analatom’s uLPR sensors in a series of accelerated tests. LPR measurements were sampled at a rate of once per minute and converted to a corrosion rate using the algorithms presented in this paper. At the end of the experiment, pitdepth due to corrosion was computed for each sensor from the recorded LPR measurements and compared to the average pit-depth measured on the control coupons. The results demonstrate the effectiveness of the sensor as an efficient and practical approach to measuring pit-depth for AA 7075-T6.
- 3 July 2012
- Published by PHM Society in Phm Society European Conference
- Vol. 1 (1)
Open AccessTheoretical and Experimental Evaluation of a Real-Time Corrosion Monitoring System for Measuring Pitting in Aircraft Structures
This paper presents the theory and experimental validation of Analatom’s Structural Health Management (SHM) system for monitoring corrosion. Corrosion measurements are acquired using a micro-sized Linear Polarization Resistance (uLPR) sensor. The uLPR sensor is based on conventional macrosized Linear Polarization Resistance (LPR) sensors with the additional benefit of a reduced form factor making it a viable and economical candidate for remote corrosion monitoring of high value structures, such as buildings, bridges, or aircraft. A series of experiments were conducted to evaluate the uLPR sensor for AA 7075-T6. Test coupons were placed alongside Analatom’s uLPR sensors in a series of accelerated tests. LPR measurements were sampled at a rate of once per minute and converted to a corrosion rate using the algorithms presented in this paper. At the end of the experiment, pitdepth due to corrosion was computed for each sensor from the recorded LPR measurements and compared to the average pit-depth measured on the control coupons. The results demonstrate the effectiveness of the sensor as an efficient and practical approach to measuring pit-depth for AA 7075-T6.
- 9 May 2011
- Published by Springer Nature
- p. 765-772
Portable Maintenance Support Tool Enhancing Battle Readiness of MDA Structures and Vehicles
- 9 May 2011
- Published by Springer Nature
- p. 765-772
Portable Maintenance Support Tool Enhancing Battle Readiness of MDA Structures and Vehicles