Douglas Brown
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Douglas Brown has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Bernard Laskowski
Analatom, Inc., 562 E. Weddell Dr. Suite 4, Sunnyvale, CA 94089-2108, USA
4 shared publications - Duane Darr
Analatom, Inc., 562 E. Weddell Dr. Suite 4, Sunnyvale, CA 94089-2108, USA
3 shared publications - Jefferey Morse
Analatom, Inc
3 shared publications - Honglei Li
Department of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
2 shared publications - Margaret R. Garvan
Department of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
2 shared publications - Richard J. Connolly
Analatom, Inc., 3210 Scott Blvd., Santa Clara, CA 95054, USA
2 shared publications
Latest Publications
- 30 November 2014
- Published by Springer Nature
- p. 673-685
Corrosion Detection on Buried Transmission Pipelines with Micro-Linear Polarization Resistance Sensors
- 30 November 2014
- Published by Springer Nature
- p. 673-685
Corrosion Detection on Buried Transmission Pipelines with Micro-Linear Polarization Resistance Sensors
- Open Access
- 29 September 2014
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 6 (1)
Imaging and Information Processing of Pitting-Corroded Aluminum Alloy Panels with Surface Metrology Methods
It has been established that corrosion is one of the most important factors causing structural deterioration, loss of metal, and ultimately decrease of product performance and reliability. Corrosion monitoring, accurate detection and interpretation are recognized as key enabling technologies to reduce the impact of corrosion on the integrity of critical aircraft and industrial assets. Interest in corrosion measurement covers a broad spectrum of technical approaches including acoustic, electrical and chemical methods. Surface metrology is an alternative approach used to measure corrosive rate and material loss by obtaining surface topography measurement at micrometer levels. This paper reports results from an experimental investigation of pitting corrosion detection and interpretation on aluminum alloy panels using 3D surface metrology methods, image processing and data mining techniques. Sample panels of AA 7075-T6, an aluminum alloy commonly used in aircraft structures, were coated on one side with a corrosion- protection coating and assembled in a lap-joint configuration. Then, a series of accelerated corrosion testing of the lap-joint panels were performed in a cyclic corrosion chamber running ASTM G85-A5 salt fog test. Panel surface characterization was evaluated with laser microscopy and stylus-based profilometry to obtain global and local surface images/characterization. Promising imaging and surface features were extracted and compared between the uncoated and coated panel sides, as well as on the uncoated sides under different corrosion exposure times. In the evaluation process, image processing, information processing and other data mining techniques were utilized. Information processing involves the steps of feature or Condition Indicator extraction and selection. The latter step addresses the problem of selecting those features that are maximally correlated with the actual corrosion state, for the purpose of corrosion detection, localization, quantification and state estimation. The results, verified by mass loss data, confirmed the contention that pits at the panel surfaces formed as a result of electrochemical corrosion attack, and showed that deteriorating pitting corrosion attack correlates with increasing corrosion exposure times. This study is a first step in the process of understanding, assessing and responding to the pitting corrosion and ultimately preventing material failure to insure aircraft structural integrity.
- 29 September 2014
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 6 (1)
Open AccessImaging and Information Processing of Pitting-Corroded Aluminum Alloy Panels with Surface Metrology Methods
It has been established that corrosion is one of the most important factors causing structural deterioration, loss of metal, and ultimately decrease of product performance and reliability. Corrosion monitoring, accurate detection and interpretation are recognized as key enabling technologies to reduce the impact of corrosion on the integrity of critical aircraft and industrial assets. Interest in corrosion measurement covers a broad spectrum of technical approaches including acoustic, electrical and chemical methods. Surface metrology is an alternative approach used to measure corrosive rate and material loss by obtaining surface topography measurement at micrometer levels. This paper reports results from an experimental investigation of pitting corrosion detection and interpretation on aluminum alloy panels using 3D surface metrology methods, image processing and data mining techniques. Sample panels of AA 7075-T6, an aluminum alloy commonly used in aircraft structures, were coated on one side with a corrosion- protection coating and assembled in a lap-joint configuration. Then, a series of accelerated corrosion testing of the lap-joint panels were performed in a cyclic corrosion chamber running ASTM G85-A5 salt fog test. Panel surface characterization was evaluated with laser microscopy and stylus-based profilometry to obtain global and local surface images/characterization. Promising imaging and surface features were extracted and compared between the uncoated and coated panel sides, as well as on the uncoated sides under different corrosion exposure times. In the evaluation process, image processing, information processing and other data mining techniques were utilized. Information processing involves the steps of feature or Condition Indicator extraction and selection. The latter step addresses the problem of selecting those features that are maximally correlated with the actual corrosion state, for the purpose of corrosion detection, localization, quantification and state estimation. The results, verified by mass loss data, confirmed the contention that pits at the panel surfaces formed as a result of electrochemical corrosion attack, and showed that deteriorating pitting corrosion attack correlates with increasing corrosion exposure times. This study is a first step in the process of understanding, assessing and responding to the pitting corrosion and ultimately preventing material failure to insure aircraft structural integrity.
- Open Access
- 29 September 2014
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 6 (1)
Electrochemical Impedance Spectroscopy for Coating Evaluation using a Micro Sensor
This paper discusses a micro-linear polarization resistance (μLPR) sensor modified to perform coating evaluation by means of electrochemical impedance spectroscopy (EIS). A circuit model is used with the EIS data to measure solution resistance, pore resistance, charge transfer resistance, intact coating capacitance, and double layer capacitance. These measurements allow the end user to monitor degradation of protective coatings in real-time, through non-destructive means. This is demonstrated through an accelerated aging test using a coated metal plate with a modified μLPR sensor. A metal panel made from aluminum alloy 7075-T6 was coated with 2 mils of an epoxy-based polymer coating and 2 mils of high solids polyurethane. The sensor was adhered to the face of the coated panel in a manner that allowed the electrolyte solution consisting of 3.5% NaCl to flow between the sensor and the coated surface of the panel. EIS measurements were acquired every hour for a total of 35 hours and at the conclusion of the test, changes in key parameters within the circuit model identified the initial time and mechanism of coating degradation, in this case, delamination
- 29 September 2014
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 6 (1)
Open AccessElectrochemical Impedance Spectroscopy for Coating Evaluation using a Micro Sensor
This paper discusses a micro-linear polarization resistance (μLPR) sensor modified to perform coating evaluation by means of electrochemical impedance spectroscopy (EIS). A circuit model is used with the EIS data to measure solution resistance, pore resistance, charge transfer resistance, intact coating capacitance, and double layer capacitance. These measurements allow the end user to monitor degradation of protective coatings in real-time, through non-destructive means. This is demonstrated through an accelerated aging test using a coated metal plate with a modified μLPR sensor. A metal panel made from aluminum alloy 7075-T6 was coated with 2 mils of an epoxy-based polymer coating and 2 mils of high solids polyurethane. The sensor was adhered to the face of the coated panel in a manner that allowed the electrolyte solution consisting of 3.5% NaCl to flow between the sensor and the coated surface of the panel. EIS measurements were acquired every hour for a total of 35 hours and at the conclusion of the test, changes in key parameters within the circuit model identified the initial time and mechanism of coating degradation, in this case, delamination
- Open Access
- 29 September 2014
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 6 (1)
A Novel Linear Polarization Resistance Corrosion Sensing Methodology for Aircraft Structure
A direct method of measuring corrosion on a structure using a micro-linear polarization resistance (μLPR) sensor is presented. The new three-electrode μLPR sensor design presented in this paper improves on existing LPR sensor technology by using the structure as part of the sensor system, allowing the sensor electrodes to be made from a corrosion resistant or inert metal. This is in contrast to a two- electrode μLPR sensor where the electrodes are made from the same material as the structure. A controlled experiment, conducted using an ASTM B117 salt fog, demonstrated the three-electrode μLPR sensors have a longer lifetime and better performance when compared to the two-electrode μLPR sensors. Following this evaluation, a controlled experiment using the ASTM G85 Annex 5 standard was performed to evaluate the accuracy and precision of the three-electrode μLPR sensor when placed between lap joint specimens made from AA7075-T6. The corrosion computed from the μLPR sensors agreed with the coupon mass loss to within a 95% confidence interval. Following the experiment, the surface morphology of each lap joint was determined using laser microscopy and stylus-based profilometry to obtain local and global surface images of the test panels. Image processing, feature extraction, and selection tools were then employed to identify the corrosion mechanism (e.g. pitting, intergranular).
- 29 September 2014
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 6 (1)
Open AccessA Novel Linear Polarization Resistance Corrosion Sensing Methodology for Aircraft Structure
A direct method of measuring corrosion on a structure using a micro-linear polarization resistance (μLPR) sensor is presented. The new three-electrode μLPR sensor design presented in this paper improves on existing LPR sensor technology by using the structure as part of the sensor system, allowing the sensor electrodes to be made from a corrosion resistant or inert metal. This is in contrast to a two- electrode μLPR sensor where the electrodes are made from the same material as the structure. A controlled experiment, conducted using an ASTM B117 salt fog, demonstrated the three-electrode μLPR sensors have a longer lifetime and better performance when compared to the two-electrode μLPR sensors. Following this evaluation, a controlled experiment using the ASTM G85 Annex 5 standard was performed to evaluate the accuracy and precision of the three-electrode μLPR sensor when placed between lap joint specimens made from AA7075-T6. The corrosion computed from the μLPR sensors agreed with the coupon mass loss to within a 95% confidence interval. Following the experiment, the surface morphology of each lap joint was determined using laser microscopy and stylus-based profilometry to obtain local and global surface images of the test panels. Image processing, feature extraction, and selection tools were then employed to identify the corrosion mechanism (e.g. pitting, intergranular).
- Open Access
- 23 September 2012
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 4 (1)
Real-Time Corrosion Monitoring of Aircraft Structures with Prognostic Applications
This paper presents the theory and experimental validation of a Structural Health Management (SHM) system for monitoring corrosion. Corrosion measurements are acquired using a micro-sized Linear Polarization Resistance (μLPR) sensor. The μLPR sensor is based on conventional macro-sized Linear Polarization Resistance (LPR) sensors with the additional benefit of a reduced form factor making it a viable and economical candidate for remote corrosion monitoring of high value structures, such as buildings, bridges, or aircraft.A series of experiments were conducted to evaluate the μLPR sensor for AA 7075-T6, a common alloy used in aircraft structures. Twelve corrosion coupons were placed alongside twenty-four μLPR sensors in a series of accelerated tests. LPR measurements were sampled once per minute and converted to a corrosion rate using the algorithms presented in this paper. At the end of the experiment, pit-depth due to corrosion was computed from each μLPR sensor and compared with the control coupons.The paper concludes with a feasibility study for the μLPR sensor in prognostic applications. Simultaneous evaluation of twenty-four μLPR sensors provided a stochastic data set appropriate for prognostics. RUL estimates were computed a-posteriori for three separate failure thresholds. The results demonstrate the effectiveness of the sensor as an efficient and practical approach to measuring pit-depth for aircraft structures, such as AA 7075-T6, and provide feasibility for its use in prognostic applications.
- 23 September 2012
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 4 (1)
Open AccessReal-Time Corrosion Monitoring of Aircraft Structures with Prognostic Applications
This paper presents the theory and experimental validation of a Structural Health Management (SHM) system for monitoring corrosion. Corrosion measurements are acquired using a micro-sized Linear Polarization Resistance (μLPR) sensor. The μLPR sensor is based on conventional macro-sized Linear Polarization Resistance (LPR) sensors with the additional benefit of a reduced form factor making it a viable and economical candidate for remote corrosion monitoring of high value structures, such as buildings, bridges, or aircraft.A series of experiments were conducted to evaluate the μLPR sensor for AA 7075-T6, a common alloy used in aircraft structures. Twelve corrosion coupons were placed alongside twenty-four μLPR sensors in a series of accelerated tests. LPR measurements were sampled once per minute and converted to a corrosion rate using the algorithms presented in this paper. At the end of the experiment, pit-depth due to corrosion was computed from each μLPR sensor and compared with the control coupons.The paper concludes with a feasibility study for the μLPR sensor in prognostic applications. Simultaneous evaluation of twenty-four μLPR sensors provided a stochastic data set appropriate for prognostics. RUL estimates were computed a-posteriori for three separate failure thresholds. The results demonstrate the effectiveness of the sensor as an efficient and practical approach to measuring pit-depth for aircraft structures, such as AA 7075-T6, and provide feasibility for its use in prognostic applications.
- Open Access
- 3 July 2012
- Published by PHM Society in Phm Society European Conference
- Vol. 1 (1)
Theoretical and Experimental Evaluation of a Real-Time Corrosion Monitoring System for Measuring Pitting in Aircraft Structures
This paper presents the theory and experimental validation of Analatom’s Structural Health Management (SHM) system for monitoring corrosion. Corrosion measurements are acquired using a micro-sized Linear Polarization Resistance (uLPR) sensor. The uLPR sensor is based on conventional macrosized Linear Polarization Resistance (LPR) sensors with the additional benefit of a reduced form factor making it a viable and economical candidate for remote corrosion monitoring of high value structures, such as buildings, bridges, or aircraft. A series of experiments were conducted to evaluate the uLPR sensor for AA 7075-T6. Test coupons were placed alongside Analatom’s uLPR sensors in a series of accelerated tests. LPR measurements were sampled at a rate of once per minute and converted to a corrosion rate using the algorithms presented in this paper. At the end of the experiment, pitdepth due to corrosion was computed for each sensor from the recorded LPR measurements and compared to the average pit-depth measured on the control coupons. The results demonstrate the effectiveness of the sensor as an efficient and practical approach to measuring pit-depth for AA 7075-T6.
- 3 July 2012
- Published by PHM Society in Phm Society European Conference
- Vol. 1 (1)
Open AccessTheoretical and Experimental Evaluation of a Real-Time Corrosion Monitoring System for Measuring Pitting in Aircraft Structures
This paper presents the theory and experimental validation of Analatom’s Structural Health Management (SHM) system for monitoring corrosion. Corrosion measurements are acquired using a micro-sized Linear Polarization Resistance (uLPR) sensor. The uLPR sensor is based on conventional macrosized Linear Polarization Resistance (LPR) sensors with the additional benefit of a reduced form factor making it a viable and economical candidate for remote corrosion monitoring of high value structures, such as buildings, bridges, or aircraft. A series of experiments were conducted to evaluate the uLPR sensor for AA 7075-T6. Test coupons were placed alongside Analatom’s uLPR sensors in a series of accelerated tests. LPR measurements were sampled at a rate of once per minute and converted to a corrosion rate using the algorithms presented in this paper. At the end of the experiment, pitdepth due to corrosion was computed for each sensor from the recorded LPR measurements and compared to the average pit-depth measured on the control coupons. The results demonstrate the effectiveness of the sensor as an efficient and practical approach to measuring pit-depth for AA 7075-T6.