DDDuane Darr

Duane Darr

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Duane Darr has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Corrosion Detection on Buried Transmission Pipelines with Micro-Linear Polarization Resistance Sensors

    by Richard J. Connolly, Douglas Brown, Duane Darr, Jeffrey Morse, Bernard Laskowski


  • Open Access

    Linear Polarization Resistance Sensor Using the Structure as aWorking Electrode

    by Douglas W. Brown, Richard J. Connolly, Duane R. Darr, Bernard Laskowski

    A direct method of measuring corrosion on a structure using a micro-linear polarization resistance (mLPR) sensor is presented. The sensor includes three electrodes, where each electrode is fabricated on a flexible substrate to create a circuit consisting of gold-plated copper. The first two electrodes, or the counter and reference electrodes, are configured in an interdigitated fashion with a separation distance of 8mil. The flex cable contains a porous membrane between the pair of electrodes and the structure. A third electrode, or the working electrode makes electrical contact to the structure through a 1mil thick electrically conductive transfer tape placed between the electrode and structure. The reference and counter electrodes are electrically isolated from the working electrode and physically separated from the surface of the structure by 1mil. The flex cable can be attached to the structure through the use of adhesives or in the case of placement in a butt joint or lap joint configuration, by the joint itself. Corrosion is computed from known physical constants, by measuring the polarization resistance between the electrolytic solution and the structure. A controlled experiment using the ASTM G85 Annex 5 standard verifies the precision and accuracy of sensor measurements by comparing the estimated mass loss with witness coupons.


  • Open Access

    Real-Time Corrosion Monitoring of Aircraft Structures with Prognostic Applications

    by Douglas Brown, Duane Darr, Jefferey Morse, Bernard Laskowski

    This paper presents the theory and experimental validation of a Structural Health Management (SHM) system for monitoring corrosion. Corrosion measurements are acquired using a micro-sized Linear Polarization Resistance (μLPR) sensor. The μLPR sensor is based on conventional macro-sized Linear Polarization Resistance (LPR) sensors with the additional benefit of a reduced form factor making it a viable and economical candidate for remote corrosion monitoring of high value structures, such as buildings, bridges, or aircraft.A series of experiments were conducted to evaluate the μLPR sensor for AA 7075-T6, a common alloy used in aircraft structures. Twelve corrosion coupons were placed alongside twenty-four μLPR sensors in a series of accelerated tests. LPR measurements were sampled once per minute and converted to a corrosion rate using the algorithms presented in this paper. At the end of the experiment, pit-depth due to corrosion was computed from each μLPR sensor and compared with the control coupons.The paper concludes with a feasibility study for the μLPR sensor in prognostic applications. Simultaneous evaluation of twenty-four μLPR sensors provided a stochastic data set appropriate for prognostics. RUL estimates were computed a-posteriori for three separate failure thresholds. The results demonstrate the effectiveness of the sensor as an efficient and practical approach to measuring pit-depth for aircraft structures, such as AA 7075-T6, and provide feasibility for its use in prognostic applications.


  • Open Access

    Theoretical and Experimental Evaluation of a Real-Time Corrosion Monitoring System for Measuring Pitting in Aircraft Structures

    by Douglas Brown, Duane Darr, Jefferey Morse, Bernard Laskowski

    This paper presents the theory and experimental validation of Analatom’s Structural Health Management (SHM) system for monitoring corrosion. Corrosion measurements are acquired using a micro-sized Linear Polarization Resistance (uLPR) sensor. The uLPR sensor is based on conventional macrosized Linear Polarization Resistance (LPR) sensors with the additional benefit of a reduced form factor making it a viable and economical candidate for remote corrosion monitoring of high value structures, such as buildings, bridges, or aircraft. A series of experiments were conducted to evaluate the uLPR sensor for AA 7075-T6. Test coupons were placed alongside Analatom’s uLPR sensors in a series of accelerated tests. LPR measurements were sampled at a rate of once per minute and converted to a corrosion rate using the algorithms presented in this paper. At the end of the experiment, pitdepth due to corrosion was computed for each sensor from the recorded LPR measurements and compared to the average pit-depth measured on the control coupons. The results demonstrate the effectiveness of the sensor as an efficient and practical approach to measuring pit-depth for AA 7075-T6.