MKMakoto Kondo

Makoto Kondo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Makoto Kondo has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Atsushi Shimizu

    Department of HTTR, Oarai Research and Development Center, Sector of Nuclear Science Research, Japan Atomic Energy Agency, 4002 Narita-Cho, Higashi-ibarakigun, Oarai-machi 311-1393, Ibaraki, Japan

    2 shared publications
  • Daisuke Tochio

    HTTR Reactor Engineering Section, Department of HTTR, Oarai Research and Development Center, Sector of Nuclear Science Research, Japan Atomic Energy Agency, Higashi-ibaraki-gun, Oarai 311-1393, Ibaraki, Japan

    2 shared publications
  • Kazuhiko Iigaki

    Department of HTTR, Oarai Research and Development Center, Sector of Nuclear Science Research, Japan Atomic Energy Agency, 4002 Narita-Cho, Higashi-ibarakigun, Oarai-machi 311-1393, Ibaraki, Japan

    2 shared publications
  • Kazuhiro Sawa

    HTTR Reactor Engineering Section Department of HTTR Oarai Research and Development Center Sector of Nuclear Science Research Japan Atomic Energy Agency (JAEA)

    2 shared publications
  • Masanori Shinohara

    HTTR Reactor Engineering Section Department of HTTR Oarai Research and Development Center Sector of Nuclear Science Research Japan Atomic Energy Agency (JAEA)

    2 shared publications
  • Shigeaki Nakagawa

    Sector of Fast Reactor and Advanced Reactor Research and Development, Japan Atomic Energy Agency

    2 shared publications

Latest Publications

  • Investigation of Countermeasure Against Local Temperature Rise in Vessel Cooling System in Loss of Core Cooling Test Without Nuclear Heating

    by Masato Ono, Atsushi Shimizu, Makoto Kondo, Yosuke Shimazaki, Masanori Shinohara, Daisuke Tochio, Kazuhiko Iigaki, Shigeaki Nakagawa, Shoji Takada, Kazuhiro Sawa

    In the loss of core cooling test using High Temperature engineering Test Reactor (HTTR), the forced cooling of the reactor core is stopped without inserting control rods into the core and, furthermore, without cooling by the vessel cooling system (VCS) to verify safety evaluation codes to investigate the inherent safety of high-temperature gas-cooled reactor (HTGR) be secured by natural phenomena to make it possible to design a severe accident-free reactor. The VCS passively removes the retained residual heat and the decay heat from the core via the reactor pressure vessel (RPV) by natural convection and thermal radiation. In the test, the local temperature was supposed to exceed the limit from the viewpoint of long-term use at the uncovered water-cooling tube without thermal reflectors in the VCS, although the safety of reactor is kept. Through a cold test, which was carried out by non-nuclear heat input from helium gas circulators (HGCs) by stopping water flow in the VCS, the local higher temperature position was specified in the uncovered water-cooling tube of the VCS, although the temperature was sufficiently lower than the maximum allowable working temperature, and the natural circulation of water had an insufficient cooling effect on the temperature of the water-cooling tube below 1°C. Then, a new safe and secured procedure for the loss of core cooling test was established, which will be carried out soon after the restart of HTTR.

  • ICONE23-1636 Investigation of Characteristics of Natural Circulation of Water in Vessel Cooling System in Loss of Core Cooling Test without Nuclear Heating

    by Shoji Takada, Atsushi Shimizu, Makoto Kondo, Yosuke Shimazaki, Masanori Shinohara, Tomokazu Seki, Daisuke Tochio, Kazuhiko Iigaki, Shigeaki Nakagawa, Kazuhiro Sawa

    In the loss of forced core cooling test using High Temperature engineering Test Reactor (HTTR), the forced cooling of reactor core is stopped without inserting control rods into the core and cooling by Vessel Cooling System (VCS) to demonstrate the inherent safety of HTGR be secured by natural phenomena to make it possible to design a severe accident free reactor. The VCS passively removes the retained residual heat and the decay heat from the core via the reactor pressure vessel by natural convection and thermal radiation. In the test, the local temperature was supposed to exceed the limit from the viewpoint of long-term use at the uncovered water cooling tube by thermal reflectors in the VCS, although the safety of reactor is kept. Through a cold test, which was carried out by non-nuclear heat input from gas circulators with stopping water flow in the VCS, the local higher temperature position was specified although the temperature was sufficiently lower than the maximum allowable working temperature, and natural circulation of water had insufficient cooling effect on the temperature of water cooling tube below 1℃. Then, a new safe and secured procedure for the loss of forced core cooling test was established, which will be carried out soon after the restart of HTTR.